Optical calibration of a digital micromirror device (DMD)-based compressive imaging (CI) system

2009 ◽  
Author(s):  
Y. Wu ◽  
C. Chen ◽  
P. Ye ◽  
Z. Wang ◽  
G. R. Arce ◽  
...  
2020 ◽  
Vol 10 (13) ◽  
pp. 4466
Author(s):  
Xuelin Lei ◽  
Xiaoshan Ma ◽  
Zhen Yang ◽  
Xiaodong Peng ◽  
Yun Li ◽  
...  

Long-distance imaging in time-varying scattering media, such as atmosphere, is a significant challenge. Light is often heavily diffused while propagating through scattering media, because of which the clear imaging of objects concealed by media becomes difficult. In this study, instead of suppressing diffusion by multiple scattering, we used natural randomness of wave propagation through atmospheric scattering media as an optimal and instantaneous compressive imaging mechanism. A mathematical model of compressive imaging based on the modulation of atmospheric scattering media was established. By using the Monte Carlo method, the atmospheric modulation matrix was obtained, and the numerical simulation of modulation imaging of atmospheric scattering media was performed. Comparative experiments show that the atmospheric matrix can achieve the same modulation effect as the Hadamard and Gaussian random matrices. The effectiveness of the proposed optical imaging approach was demonstrated experimentally by loading the atmospheric measurement matrix onto a digital micromirror device to perform single pixel compressive sensing measurements. Our work provides a new direction to ongoing research in the field of imaging through scattering media.


2021 ◽  
Vol 29 (4) ◽  
pp. 5710
Author(s):  
Jun Ke ◽  
Linxia Zhang ◽  
Qun Zhou ◽  
Edmund Y. Lam

2021 ◽  
Vol 15 ◽  
pp. 174830262110080
Author(s):  
Changjun Zha* ◽  
Qian Zhang* ◽  
Huimin Duan

Traditional single-pixel imaging systems are aimed mainly at relatively static or slowly changing targets. When there is relative motion between the imaging system and the target, sizable deviations between the measurement values and the real values can occur and result in poor image quality of the reconstructed target. To solve this problem, a novel dynamic compressive imaging system is proposed. In this system, a single-column digital micro-mirror device is used to modulate the target image, and the compressive measurement values are obtained for each column of the image. Based on analysis of the measurement values, a new recovery model of dynamic compressive imaging is given. Differing from traditional reconstruction results, the measurement values of any column of vectors in the target image can be used to reconstruct the vectors of two adjacent columns at the same time. Contingent upon characteristics of the results, a method of image quality enhancement based on an overlapping average algorithm is proposed. Simulation experiments and analysis show that the proposed dynamic compressive imaging can effectively reconstruct the target image; and that when the moving speed of the system changes within a certain range, the system reconstructs a better original image. The system overcomes the impact of dynamically changing speeds, and affords significantly better performance than traditional compressive imaging.


2020 ◽  
Vol 134 ◽  
pp. 106122
Author(s):  
Jadze Princeton C. Narag ◽  
Niña Angelica F. Zambale ◽  
Nathaniel Hermosa

Micromachines ◽  
2019 ◽  
Vol 10 (2) ◽  
pp. 149 ◽  
Author(s):  
Zifeng Lu ◽  
Jinghang Zhang ◽  
Hua Liu ◽  
Jialin Xu ◽  
Jinhuan Li

In the Hadamard transform (HT) near-infrared (NIR) spectrometer, there are defects that can create a nonuniform distribution of spectral energy, significantly influencing the absorbance of the whole spectrum, generating stray light, and making the signal-to-noise ratio (SNR) of the spectrum inconsistent. To address this issue and improve the performance of the digital micromirror device (DMD) Hadamard transform near-infrared spectrometer, a split waveband scan mode is proposed to mitigate the impact of the stray light, and a new Hadamard mask of variable-width stripes is put forward to improve the SNR of the spectrometer. The results of the simulations and experiments indicate that by the new scan mode and Hadamard mask, the influence of stray light is restrained and reduced. In addition, the SNR of the spectrometer also is increased.


2019 ◽  
Vol 125 (2) ◽  
Author(s):  
Jinliang Li ◽  
Xiao Chen ◽  
Min Lv ◽  
Yunshu Gao ◽  
Genxiang Chen

Sign in / Sign up

Export Citation Format

Share Document