Direct identification and susceptibility testing of gram-negative bacilli from BACTEC bottles by use of the MS-2 system with updated bacterial identification software.

1984 ◽  
Vol 20 (6) ◽  
pp. 1202-1204 ◽  
Author(s):  
J R Dipersio ◽  
S M Ficorilli ◽  
F J Varga
2020 ◽  
Vol 7 (Supplement_1) ◽  
pp. S383-S383
Author(s):  
Charma Henry ◽  
Dustin Evans ◽  
Daniel Navas ◽  
Arleen Barker ◽  
Chonnapat Somyos ◽  
...  

Abstract Background The national average of identification and susceptibility for organisms isolated from positive blood culture to final susceptibility based on growth on solid media is 48 hours. The goal of this research was to prove that the Vitek®2 (bioMérieux, Inc.) system can provide an accurate and reliable susceptibility result directly from positive blood culture for Gram negative rods and reduce the turnaround time (TAT) from positive blood culture to the final susceptibility. Methods An FDA-modified validation procedure was performed on positive blood cultures directly from the bottle to the VITEK®2 System for susceptibility testing. The protocol tested and validated an aliquot of 50uL of blood directly from the positive bottle into 10 mL of saline (1:200). The solution was vortexed and 3mL were placed in the VITEK®2 test tube. This protocol was intended only for Gram negative rods using the AST-GN70, AST-GN81 & AST-GN801 cards. This protocol followed the CLSI M52 and M100 guidelines. Results 515 organisms from clinical blood culture samples from July 2018 to October 2019 were evaluated. Organisms included, but were not limited to: E. coli, K. pneumoniae, Enterobacter spp., and P. aeruginosa, Proteus spp., Salmonella spp., Acinetobacter spp., and S. maltophilia. There were 5,201 drug/bug combinations. AdventHealth Orlando achieved an essential agreement of 99.32% (n=5,166), minor error 0.74% (n=39) major error 0.02% (n=1) and very major error 0.49% (n=2). A 100% agreement was achieved on detection of ESBL, CRE, and MDR organisms. Conclusion Rapid direct blood culture protocol using the VITEK®2 System and the AST-GN cards is accurate, reliable and can be performed with less than 1 minute hands-on time. The protocol can be implemented in any laboratory at no additional costs or modification where the current VITEK®2 AST-GN panels are in use. This protocol was clinically implemented at AdventHealth Orlando on July 15, 2019. Compared with the national average of 72 hours, the TAT obtained during this study was 23 hours from positive blood culture to final susceptibility, a significant reduction of 25 hours. The authors encourage bioMérieux Inc. to evaluate and explore the opportunity to expand the use of the VITEK®2 system for this application with the appropriate clinical trial. Disclosures All Authors: No reported disclosures


Author(s):  
Kavipriya D. ◽  
Suman Susan Prakash ◽  
Sarumathi Dhandapani ◽  
Deepashree Rajshekar ◽  
Apurba Sankar Sastry

Abstract Background Timely initiation of antimicrobial therapy in patients with blood stream infection is absolutely necessary to reduce mortality and morbidity. Most clinical microbiology laboratories use conventional methods for identification and antimicrobial susceptibility testing (AST) that involve biochemical methods for identification followed by AST by disk diffusion. The aim of the current study is to assess the various errors associated with direct susceptibility testing done from blood culture broth using automated AST system-Vitek-2 compact compared with the reference method of AST done from bacterial colonies. Materials and Methods The study was conducted in a tertiary care public sector 2,200-bedded hospital in South India for a period of 6 months. The study involved positively flagged blood culture bottles that yielded single morphotype of Gram-negative organism by Gram stain. A total of 120 bacterial isolates were collected that consisted of consecutively obtained first 60 isolates of Enterobacteriaceae family (30 Escherichia coli and 30 Klebsiella pneumoniae) and consecutively obtained first 60 nonfermenters (30 Pseudomonas aeruginosa and 30 Acinetobacter baumannii). Vitek-2 AST was done from these 120 blood culture broth, following the protocol by Biomerieux, and results were obtained. Then, Vitek-2 was done from colonies (reference method) using appropriate panel for Enterobacteriaceae and nonfermenters, and results were obtained. Both the results were compared. Results Nonfermenters showed a better categorical agreement of 97.6%, as compared to Enterobacteriaceae, which showed 97%. Among Enterobacteriaceae, both E. coli and K. pneumoniae showed categorical agreement of 97% each. Conclusion The procedure of AST directly from blood culture broth represents a simple and effective technique that can reduce the turnaround time by 24 hours, which in turn benefits the clinician in appropriate utilization of antimicrobials for better patient care.


Sign in / Sign up

Export Citation Format

Share Document