scholarly journals Comparisons of standard curve-fitting methods to quantitate Neisseria meningitidis group A polysaccharide antibody levels by enzyme-linked immunosorbent assay.

1991 ◽  
Vol 29 (7) ◽  
pp. 1439-1446 ◽  
Author(s):  
B D Plikaytis ◽  
S H Turner ◽  
L L Gheesling ◽  
G M Carlone
2002 ◽  
Vol 9 (3) ◽  
pp. 725-726 ◽  
Author(s):  
Cheryl M. Elie ◽  
Patricia K. Holder ◽  
Sandra Romero-Steiner ◽  
George M. Carlone

ABSTRACT We assigned additional enzyme-linked immunosorbent assay antibody concentrations (immunoglobulin G [IgG], IgM, and IgA, and total) to the Neisseria meningitidis standard reference serum CDC1992 for groups Y and W-135 to 12 Centers for Disease Control and Prevention quality control sera. These assignments will supplement previous assignments and will aid in the evaluation of present and developing vaccines.


2000 ◽  
Vol 12 (3) ◽  
pp. 245-252 ◽  
Author(s):  
Stewart W. Alcorn ◽  
Ronald J. Pascho

An enzyme-linked immunosorbent assay (ELISA) was developed on the basis of testing a single dilution of serum to quantify the level of antibody to the p57 protein of Renibacterium salmoninarum in sockeye salmon ( Oncorhynchus nerka). The levels of antibody were interpolated from a standard curve constructed by relating the optical densities (OD) produced by several dilutions of a high-titer rainbow trout ( O. mykiss) antiserum to the p57 protein. The ELISA OD values produced by as many as 36 test sera on each microplate were compared with the standard curve to calculate the antigen-specific antibody activity. Repeated measurements of 36 samples on 3 microplates on each of 6 assay dates indicated that the mean intraassay coefficient of variation (CV) was 6.68% (range, 0–23%) and the mean interassay CV was 8.29% (range, 4–16%). The antibody levels determined for the serum sample from 24 sockeye salmon vaccinated with a recombinant p57 protein generally were correlated with the levels determined by endpoint titration ( r2 = 0.936) and with results from another ELISA that was based on extrapolation of antibody levels from a standard curve ( r2 = 0.956). The single-dilution antibody ELISA described here increases the number of samples that can be tested on each microplate compared with immunoassays based on analysis of several dilutions of each test serum. It includes controls for interassay standardization and can be used to test fish weighing <3 g.


1978 ◽  
Vol 8 (4) ◽  
pp. 419-423
Author(s):  
P O Leinikki ◽  
I Shekarchi ◽  
P Dorsett ◽  
J L Sever

A "microgram assay" is described in which solid-phase enzyme-linked immunosorbent assay is used for the determination of specific rubella immunoglobulin G (IgG) antibody levels in micrograms per milliliter of serum. The quantitation was based on a standard curve obtained by using a reference serum, for which the specific IgG content was assayed by immunochemical purification. IgG was first purified and specific rubella antibodies were separated by an immunoadsorbent prepared by linking rubella virus antigens to Sepharose 4B. By using IgG-specific conjugate, the levels of specific rubella IgG antibodies could then be determined from clinical samples. Seronegative samples showed antibody levels less than 1 microgram/ml, whereas levels up to several hundred micrograms per milliliter were detected in some postinfection sera. The correlation between microgram antibody levels and hemagglutination inhibition titers was linear. The method offers a simple and sensitive antibody assay which could be used both for the laboratory diagnosis of acute rubella and for the evaluation of immunity.


1978 ◽  
Vol 8 (3) ◽  
pp. 268-276
Author(s):  
L H Ghose ◽  
R D Schnagl ◽  
I H Holmes

The development of a micro-scale enzyme-linked immunosorbent assay (ELISA) with horseradish peroxidase as the marker enzyme for the detection and measurement of human rotavirus antibodies is described. A semipurified preparation of the serologically related simian agent, SA-11 virus, was used as the antigen. Test sera were reacted with antigen-sensitized wells in disposable poly-vinyl microplates. Any attached antibody was detected by the addition of peroxidase-labeled anti-species immunoglobulin (conjugate) followed by assay of the enzyme reaction with its substrate, hydrogen peroxide plus 5-aminosalicylic acid. This micro-ELISA was compared with complement fixation in a seroepidemiological study of the age prevalence of rotavirus antibody in Aboriginal and European populations living in the same outback area in Australia. The ELISA (results read with the naked eye) proved to be approximately 16 times more sensitive than complement fixation. Of Aborigines, 71% had rotavirus complement-fixing antibody, as compared to 45% of Europeans. By ELISA 100% of both populations had rotavirus antibodies. Mean antibody titers in the different age groups were higher in Aborigines than in Europeans. Antibody levels rose steeply throughout the first 20 years of life, remained high during the next 20 years, then increased again at least up to the age of 60 years. The micro-ELISA was practical, simple to perform, and more suitable than complement fixation for large seroepidemiological rotavirus studies. It also has potential for serodiagnosis of the disease, both in the laboratory and in the field.


1988 ◽  
Vol 101 (2) ◽  
pp. 405-410 ◽  
Author(s):  
R. C. H Lau

SUMMARYEnzyme-linked immunosorbent assay (ELISA) tests were used to measure IgG antibody levels in 2638 New Zealand children who had been immunized with the triple vaccine DTP. The percentage of children immune to diphtheria decreased with age. The percentage of children immune to tetanus varied from 67.1 to 55.0%. The percentage of children with measurable antibody to pertussis increased with age. The mean percentages of children with measurable antibody or immunity to one or more DTP components were 34.2% (with 3 components), 34.4% (2 components), and 78.1% (1 component). It appears the immunization strategy for diphtheria and tetanus is satisfactory for herd immunity in New Zealand children. However, the current pertussis strategy may not be providing adequate immunity to 5-year-olds in this country.


1998 ◽  
Vol 5 (5) ◽  
pp. 613-616 ◽  
Author(s):  
Felix Grimm ◽  
Friedrich E. Maly ◽  
Jian Lü ◽  
Roberto Llano

ABSTRACT The potential roles of specific antibodies of the different immunoglobulin G (IgG) subclasses in the serological diagnosis of cystic echinococcosis (CE) and alveolar echinococcosis (AE) were investigated by an enzyme-linked immunosorbent assay based on hydatid fluid as antigen. Specific antibodies of subclass 1 were found to be of major importance. In sera collected at the time of diagnosis (i.e., before any therapeutic intervention was initiated) they could be demonstrated in 14 of 15 sera from patients with CE and in all 12 sera from patients with AE. The most discriminatory and the most specific antibodies found in this study belonged to IgG subclass 4. Only one false-positive reaction was observed with 253 sera from healthy volunteers, and no cross-reactions occurred in 80 sera from patients with different parasitic infections. Specific IgG4 antibodies could be demonstrated in 61.0 to 66.7% (CE) or 47.6 to 66.7% (AE) of the cases. Antibody levels of IgG subclass 2 were elevated only moderately, and subclass 3 antibodies were detected in a few cases only. In addition, nonspecific reactions in sera of healthy volunteers or patients with other parasitic infections could partially be attributed to antibodies of subclasses 2 and 3.


1990 ◽  
Vol 73 (3) ◽  
pp. 451-456 ◽  
Author(s):  
Fun S Chu ◽  
Xuan Huang ◽  
R D Wei

Abstract A direct competitive enzyme-linked immunosorbent assay (ELISA) for the freshwater blue-green algal toxin mlcrocystln (MCYST) In algae and water was developed. The assay Involves coating antl-MCYST-variant leuclne-arglnine (LR) antibody to the ELISA plate and the use of MCYST-LRperoxidase as the enzyme marker. The linear portion of the standard curve for MCYST in phosphate buffer containing saline (PBS) was 0.5-10.0 ng/mL (25-500 pg/assay). The minimum detection level for MCYST-LR was 0.20 ng/mL (10 pg/assay). Contaminated water could be directly used In the ELISA. The overall analytical recoveries for MCYST-LR added to water at levels of 1-20 ng/mL was 83.4%. For analysis of cellular MCYST, the toxin was first extracted from the algae with 0.1M ammonium bicarbonate, diluted with PBS to less than 0.5 mg dried algae/mL (&lt;5.0 mg wet welght/mL) and directly used in the ELISA. C-18 reverse-phase Sep-Pak cartridges effectively adsorbed MCYST from the toxln-containlng solutions. The toxin could be recovered from the cartridge by elutlng with 60% methanol. Using this approach, an algae extract that was relatively free of MCYST was prepared and was used in a recovery study. The overall analytical recovery of MCYST added to the algae extract In the range of 0.25-20 ppm was 83% with a coefficient of variation of 11.9%. The detection limit for MCYST In dried algae was about 0.25-0.5 pg/g (0.25-0.5 ppm) lyophlllzed algae sample. This method was applied for the analysis of several naturally occurring algal blooms. Limited samples were also analyzed for MYCST by liquid chromatography. ELISA data were in general agreement with those obtainedby liquid chromatography. MCYST concentrations from 0.006 to 2.9 fig/g (6 to 2900 ppb) and from 26 to 5200 /ig/g (26 ppm to 5200 ppm) were found In water and algae (dried weight), respectively


Sign in / Sign up

Export Citation Format

Share Document