NITRATE REDUCTION FROM TILE DRAINAGE IN A RESTORED OXBOW WETLAND

2016 ◽  
Author(s):  
Stephen J. Kalkhoff ◽  
◽  
Joseph Schubauer-Berigan
2017 ◽  
Vol 102 ◽  
pp. 98-107 ◽  
Author(s):  
Keith E. Schilling ◽  
Keegan Kult ◽  
Karen Wilke ◽  
Matthew Streeter ◽  
Jason Vogelgesang

1975 ◽  
Vol 4 (2) ◽  
pp. 179-182 ◽  
Author(s):  
M. G. Volz ◽  
L. W. Belser ◽  
M. S. Ardakani ◽  
A. D. McLaren
Keyword(s):  

2006 ◽  
Vol 41 (1) ◽  
pp. 63-71 ◽  
Author(s):  
Nicolas Stämpfli ◽  
Chandra A. Madramootoo

Abstract Recent studies have shown subirrigation (SI) to be effective in reducing nitrate losses from agricultural tile drainage systems. A field study was conducted from 2001 to 2002 in southwestern Québec to evaluate the effect of SI on total dissolved phosphorus (TDP) losses in tile drainage. In an agricultural field with drains installed at a 1-m depth, a SI system with a design water table depth (WTD) of 0.6 m below the soil surface was compared with conventional free drainage (FD). Subirrigation increased drainage outflow volumes in the autumn, when drains were opened and water table control was interrupted for the winter in the SI plots. Outflows were otherwise similar for both treatments. Throughout the study, the TDP concentrations in tile drainage were significantly higher with SI than with FD for seven out of 17 of the sampling dates for which data could be analyzed statistically, and they were never found to be lower for plots under SI than for plots under FD. Of the seven dates for which the increase was significant, six fell in the period during which water table control was not implemented (27 September 2001 to 24 June 2002). Hence, it appears that SI tended to increase TDP concentrations compared with FD, and that it also had a residual effect between growing seasons. Almost one-third of all samples from the plots under SI exceeded Québec's surface water quality standard (0.03 mg TDP L-1), whereas concentrations in plots under FD were all below the standard. Possible causes of the increase in TDP concentrations in tile drainage with SI are high TDP concentrations found in the well water used for SI and a higher P solubility caused by the shallow water table.


BIO-PROTOCOL ◽  
2014 ◽  
Vol 4 (12) ◽  
Author(s):  
Marco Fischer ◽  
Dörte Falke ◽  
R. Sawers

2022 ◽  
Vol 169 ◽  
pp. 104164
Author(s):  
Tingting An ◽  
Feng Wang ◽  
Lingling Ren ◽  
Shihan Ma ◽  
Shuangyi Li ◽  
...  

Processes ◽  
2021 ◽  
Vol 9 (3) ◽  
pp. 405
Author(s):  
Edoardo Dell’Armi ◽  
Marco Zeppilli ◽  
Bruna Matturro ◽  
Simona Rossetti ◽  
Marco Petrangeli Papini ◽  
...  

Chlorinated aliphatic hydrocarbons (CAHs) are common groundwater contaminants due to their improper use in several industrial activities. Specialized microorganisms are able to perform the reductive dechlorination (RD) of high-chlorinated CAHs such as perchloroethylene (PCE), while the low-chlorinated ethenes such as vinyl chloride (VC) are more susceptible to oxidative mechanisms performed by aerobic dechlorinating microorganisms. Bioelectrochemical systems can be used as an effective strategy for the stimulation of both anaerobic and aerobic microbial dechlorination, i.e., a biocathode can be used as an electron donor to perform the RD, while a bioanode can provide the oxygen necessary for the aerobic dechlorination reaction. In this study, a sequential bioelectrochemical process constituted by two membrane-less microbial electrolysis cells connected in series has been, for the first time, operated with synthetic groundwater, also containing sulphate and nitrate, to simulate more realistic process conditions due to the possible establishment of competitive processes for the reducing power, with respect to previous research made with a PCE-contaminated mineral medium (with neither sulphate nor nitrate). The shift from mineral medium to synthetic groundwater showed the establishment of sulphate and nitrate reduction and caused the temporary decrease of the PCE removal efficiency from 100% to 85%. The analysis of the RD biomarkers (i.e., Dehalococcoides mccartyi 16S rRNA and tceA, bvcA, vcrA genes) confirmed the decrement of reductive dechlorination performances after the introduction of the synthetic groundwater, also characterized by a lower ionic strength and nutrients content. On the other hand, the system self-adapted the flowing current to the increased demand for the sulphate and nitrate reduction, so that reducing power was not in defect for the RD, although RD coulombic efficiency was less.


Sign in / Sign up

Export Citation Format

Share Document