Dual-energy X-ray Imaging in Combination with Automated Threshold Gabor Filtering for Baggage Screening Application

2020 ◽  
Vol 56 (9) ◽  
pp. 765-773
Author(s):  
Amir Movafeghi ◽  
Behrouz Rokrok ◽  
Effat Yahaghi
2021 ◽  
Vol 7 (7) ◽  
pp. 104
Author(s):  
Vladyslav Andriiashen ◽  
Robert van Liere ◽  
Tristan van Leeuwen ◽  
Kees Joost Batenburg

X-ray imaging is a widely used technique for non-destructive inspection of agricultural food products. One application of X-ray imaging is the autonomous, in-line detection of foreign objects in food samples. Examples of such inclusions are bone fragments in meat products, plastic and metal debris in fish, and fruit infestations. This article presents a processing methodology for unsupervised foreign object detection based on dual-energy X-ray absorptiometry (DEXA). A novel thickness correction model is introduced as a pre-processing technique for DEXA data. The aim of the model is to homogenize regions in the image that belong to the food product and to enhance contrast where the foreign object is present. In this way, the segmentation of the foreign object is more robust to noise and lack of contrast. The proposed methodology was applied to a dataset of 488 samples of meat products acquired from a conveyor belt. Approximately 60% of the samples contain foreign objects of different types and sizes, while the rest of the samples are void of foreign objects. The results show that samples without foreign objects are correctly identified in 97% of cases and that the overall accuracy of foreign object detection reaches 95%.


2021 ◽  
Author(s):  
Daniel Arturo Cardenas

Strontium-based medications, such as strontium ranelate, have been shown to have therapeutic effects in the treatment of osteoporosis, other strontium salts are assumed to have similar effects on bone health. The objective of this study was to compare the distribution of strontium in animal bones following administration of strontium ranelate and strontium citrate. Humerus bones were collected from female Sprague-Dawley rats that were dosed daily over ten weeks with strontium ranelate and strontium citrate, and no strontium (control). Bones were imaged using 2D micro-XRF and 3D dual energy KES X-ray imaging. The 2D imaging revealed differences in strontium and calcium levels between samples from treated and non-treated animals (푝 < 0.001). 3D images obtained showed that strontium was observed to be largely present in the trabecular regions under the epiphyseal plate with concentrations of approximately 5 to 15 mg/cm3 in the bones of both strontium treated groups. The thickness of the strontium layers below the growth plate in both the strontium ranelate and strontium citrate sample were not significantly different (푝 = 0.9201). Both imaging studies performed in this work showed that strontium from both salts is heterogeneously distributed in newly formed bone during treatment.


2006 ◽  
Author(s):  
Xuanqin Mou ◽  
Shaojie Tang ◽  
Wei Hong

2015 ◽  
Vol 76 ◽  
pp. 38-42 ◽  
Author(s):  
Sergei Osipov ◽  
Eduard Libin ◽  
Sergei Chakhlov ◽  
Oleg Osipov ◽  
Alexander Shtein

2020 ◽  
Vol 164 ◽  
pp. 109267 ◽  
Author(s):  
Mahdi Kahani ◽  
Sanaz Hariri Tabrizi ◽  
Alireza Kamali-Asl ◽  
Samaneh Hashemi

Sign in / Sign up

Export Citation Format

Share Document