Near-Infrared Spectroscopy and Hydrogen Clearance: Is there any Difference between These Two Methods of Muscle Blood Volume Estimation?

2015 ◽  
Vol 33 (2) ◽  
pp. 166-167 ◽  
Author(s):  
Hidetoshi Mori ◽  
Hiroshi Kuge ◽  
Mayumi Watanabe ◽  
Tim Hideaki Tanaka
2006 ◽  
Vol 31 (1) ◽  
pp. 48-55 ◽  
Author(s):  
Kotaro Kawaguchi ◽  
Yukiko Hayashi ◽  
Kiyokazu Sekikawa ◽  
Mitsuru Tabusadani ◽  
Tsutomu Inamizu ◽  
...  

This study examined the relationship between acute cardiorespiratory and muscle oxygenation and blood volume changes during prolonged exercise. Eight healthy male volunteers (mean maximum oxygen uptake ([Formula: see text]O2max) = 41.6 ± 2.4 mL/kg/min) performed 60 min submaximal cycling at 50% [Formula: see text]O2max. Oxygen uptake ([Formula: see text]O2) was measured by indirect spirometry, cardiac output (CO) was estimated using a PortapresTM, and right vastus lateralis oxyhemoglobin/ myoglobin (oxyHb/Mb), deoxyhemoglobin/myoglobin (deoxyHb/Mb), and total hemoglobin/myoglobin (total Hb/Mb) were recorded using near-infrared spectroscopy (NIRS). After 40 min of exercise, there was a significant increase in [Formula: see text]O2 due to a significantly higher arteriovenous oxygen difference ((a - v)O2diff). After 30 min of exercise CO remained unchanged, but there was a significant decrease in stroke volume and a proportionate increase in heart rate, thus indicating the occurrence of cardiovascular drift. During the first few minutes of exercise, there was a decline in oxyHb/Mb and total Hb/Mb, whereas deoxyHb/Mb remained unchanged. Thereafter, oxyHb/Mb and total Hb/Mb increased systematically until the termination of exercise while deoxyHb/Mb declined. After 40 min of exercise, these changes were significantly different from the baseline values. There were no significant correlations between the changes in the NIRS variables and systemic [Formula: see text]O2 or mixed (a - v)O2diff during exercise. These results suggest that factors other than localized changes in muscle oxygenation and blood volume account for the increased [Formula: see text]O2 during prolonged submaximal exercise. Key words: near infrared spectroscopy, cardiovascular drift, systemic oxygen consumption.


2001 ◽  
Vol 21 (2) ◽  
pp. 110-113 ◽  
Author(s):  
Marjo J. T. Van de Ven ◽  
Willy N. J. M. Colier ◽  
Marco C. van der Sluijs ◽  
Diederik Walraven ◽  
Berend Oeseburg ◽  
...  

In some circumstances, cerebral blood volume (CBV) can be used as a measure for cerebral blood flow. A new near infrared spectroscope was used for determining the reproducibility of CBV measurements assessed by the O2-method. Twenty-seven healthy subjects were investigated. An intrasubject coefficient of variation (CV) was calculated, based on four identical episodes of desaturation–resaturation (O2-method) procedures for CBV measurements. Two trials were performed, with (trial 1) and without (trial 2) disconnecting the equipment. A mean CV of 12.6% and 10.0% was found in trial 1 and 2, respectively. Cerebral blood volume values yield 3.60 ± 0.82 mL 100 g−1. Cerebral blood volume could be measured reproducible in adults using near infrared spectroscopy, if the arterial desaturation is limited to approximately 5% from baseline level.


2017 ◽  
Vol 22 (2) ◽  
pp. 025001 ◽  
Author(s):  
Martin B. Rasmussen ◽  
Vibeke R. Eriksen ◽  
Bjørn Andresen ◽  
Simon Hyttel-Sørensen ◽  
Gorm Greisen

Sign in / Sign up

Export Citation Format

Share Document