scholarly journals Quantifying cerebral hypoxia by near-infrared spectroscopy tissue oximetry: the role of arterial-to-venous blood volume ratio

2017 ◽  
Vol 22 (2) ◽  
pp. 025001 ◽  
Author(s):  
Martin B. Rasmussen ◽  
Vibeke R. Eriksen ◽  
Bjørn Andresen ◽  
Simon Hyttel-Sørensen ◽  
Gorm Greisen
Ozone Therapy ◽  
2017 ◽  
Vol 1 (3) ◽  
pp. 56 ◽  
Author(s):  
Daniele Rimini ◽  
Filippo Molinari ◽  
William Liboni ◽  
Vincenzo Simonetti ◽  
Marianno Franzini

Ozone major autohemotherapy (O-MAHT) is a way of ozonetherapy administration consisting of drawing patient’s venous blood, mixing with oxygen/ozone, and reinfusing it into the vein. Some ozone therapists reported side effects during the O-MAHT, but the origin has not been described yet. We investigated the effect of blood drawing velocity during O-MAHT to see its effects on the vascular system and symptomatology. We administered O-MAHT to 11 subjects, and we interleaved fast and slow reinfusions. We monitored cerebral macrocirculation with transcranial Doppler (TCD) and tissue microcirculation with near-infrared spectroscopy (NIRS). Annoying symptoms appeared just during the fast reinfusion periods. NIRS and TCD parameters revealed vasoconstriction during fast reinfusion and improved metabolism during slow reinfusion. Overall, our investigation well discriminated fast from slow reinfusion velocity.


2006 ◽  
Vol 31 (1) ◽  
pp. 48-55 ◽  
Author(s):  
Kotaro Kawaguchi ◽  
Yukiko Hayashi ◽  
Kiyokazu Sekikawa ◽  
Mitsuru Tabusadani ◽  
Tsutomu Inamizu ◽  
...  

This study examined the relationship between acute cardiorespiratory and muscle oxygenation and blood volume changes during prolonged exercise. Eight healthy male volunteers (mean maximum oxygen uptake ([Formula: see text]O2max) = 41.6 ± 2.4 mL/kg/min) performed 60 min submaximal cycling at 50% [Formula: see text]O2max. Oxygen uptake ([Formula: see text]O2) was measured by indirect spirometry, cardiac output (CO) was estimated using a PortapresTM, and right vastus lateralis oxyhemoglobin/ myoglobin (oxyHb/Mb), deoxyhemoglobin/myoglobin (deoxyHb/Mb), and total hemoglobin/myoglobin (total Hb/Mb) were recorded using near-infrared spectroscopy (NIRS). After 40 min of exercise, there was a significant increase in [Formula: see text]O2 due to a significantly higher arteriovenous oxygen difference ((a - v)O2diff). After 30 min of exercise CO remained unchanged, but there was a significant decrease in stroke volume and a proportionate increase in heart rate, thus indicating the occurrence of cardiovascular drift. During the first few minutes of exercise, there was a decline in oxyHb/Mb and total Hb/Mb, whereas deoxyHb/Mb remained unchanged. Thereafter, oxyHb/Mb and total Hb/Mb increased systematically until the termination of exercise while deoxyHb/Mb declined. After 40 min of exercise, these changes were significantly different from the baseline values. There were no significant correlations between the changes in the NIRS variables and systemic [Formula: see text]O2 or mixed (a - v)O2diff during exercise. These results suggest that factors other than localized changes in muscle oxygenation and blood volume account for the increased [Formula: see text]O2 during prolonged submaximal exercise. Key words: near infrared spectroscopy, cardiovascular drift, systemic oxygen consumption.


2001 ◽  
Vol 21 (2) ◽  
pp. 110-113 ◽  
Author(s):  
Marjo J. T. Van de Ven ◽  
Willy N. J. M. Colier ◽  
Marco C. van der Sluijs ◽  
Diederik Walraven ◽  
Berend Oeseburg ◽  
...  

In some circumstances, cerebral blood volume (CBV) can be used as a measure for cerebral blood flow. A new near infrared spectroscope was used for determining the reproducibility of CBV measurements assessed by the O2-method. Twenty-seven healthy subjects were investigated. An intrasubject coefficient of variation (CV) was calculated, based on four identical episodes of desaturation–resaturation (O2-method) procedures for CBV measurements. Two trials were performed, with (trial 1) and without (trial 2) disconnecting the equipment. A mean CV of 12.6% and 10.0% was found in trial 1 and 2, respectively. Cerebral blood volume values yield 3.60 ± 0.82 mL 100 g−1. Cerebral blood volume could be measured reproducible in adults using near infrared spectroscopy, if the arterial desaturation is limited to approximately 5% from baseline level.


2020 ◽  
Vol 10 (6) ◽  
pp. 342 ◽  
Author(s):  
Fabian Herold ◽  
Thomas Gronwald ◽  
Felix Scholkmann ◽  
Hamoon Zohdi ◽  
Dominik Wyser ◽  
...  

In the literature, it is well established that regular physical exercise is a powerful strategy to promote brain health and to improve cognitive performance. However, exact knowledge about which exercise prescription would be optimal in the setting of exercise–cognition science is lacking. While there is a strong theoretical rationale for using indicators of internal load (e.g., heart rate) in exercise prescription, the most suitable parameters have yet to be determined. In this perspective article, we discuss the role of brain-derived parameters (e.g., brain activity) as valuable indicators of internal load which can be beneficial for individualizing the exercise prescription in exercise–cognition research. Therefore, we focus on the application of functional near-infrared spectroscopy (fNIRS), since this neuroimaging modality provides specific advantages, making it well suited for monitoring cortical hemodynamics as a proxy of brain activity during physical exercise.


Biosensors ◽  
2019 ◽  
Vol 9 (2) ◽  
pp. 71
Author(s):  
Tomas Ysehak Abay ◽  
Kamran Shafqat ◽  
Panayiotis A. Kyriacou

Photoplethysmography (PPG) signals from the forehead can be used in pulse oximetry as they are less affected by vasoconstriction compared to fingers. However, the increase in venous blood caused by the positioning of the patient can deteriorate the signals and cause erroneous estimations of the arterial oxygen saturation. To date, there is no method to measure this venous presence under the PPG sensor. This study investigates the feasibility of using PPG signals from the forehead in an effort to estimate relative changes in haemoglobin concentrations that could reveal these posture-induced changes. Two identical reflectance PPG sensors were placed on two different positions on the forehead (above the eyebrow and on top of a large vein) in 16 healthy volunteers during a head-down tilt protocol. Relative changes in oxygenated ( Δ HbO 2 ), reduced ( Δ HHb) and total ( Δ tHb) haemoglobin were estimated from the PPG signals and the trends were compared with reference Near Infrared Spectroscopy (NIRS) measurements. Also, the signals from the two PPG sensors were analysed in order to reveal any difference due to the positioning of the sensor. Δ HbO 2 , Δ HHb and Δ tHb estimated from the forehead PPGs trended well with the same parameters from the reference NIRS. However, placing the sensor over a large vasculature reduces trending against NIRS, introduces biases as well as increases the variability of the changes in Δ HHb. Forehead PPG signals can be used to measure perfusion changes to reveal venous pooling induced by the positioning of the subject. Placing the sensor above the eyebrow and away from large vasculature avoids biases and large variability in the measurements.


Sign in / Sign up

Export Citation Format

Share Document