scholarly journals Simultaneous measurement of preductal and postductal oxygen saturation by pulse oximetry in hyaline membrane disease.

1992 ◽  
Vol 67 (10 Spec No) ◽  
pp. 1166-1168 ◽  
Author(s):  
P D Macdonald ◽  
V Y Yu
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shinshu Katayama ◽  
Jun Shima ◽  
Ken Tonai ◽  
Kansuke Koyama ◽  
Shin Nunomiya

AbstractRecently, maintaining a certain oxygen saturation measured by pulse oximetry (SpO2) range in mechanically ventilated patients was recommended; attaching the INTELLiVENT-ASV to ventilators might be beneficial. We evaluated the SpO2 measurement accuracy of a Nihon Kohden and a Masimo monitor compared to actual arterial oxygen saturation (SaO2). SpO2 was simultaneously measured by a Nihon Kohden and Masimo monitor in patients consecutively admitted to a general intensive care unit and mechanically ventilated. Bland–Altman plots were used to compare measured SpO2 with actual SaO2. One hundred mechanically ventilated patients and 1497 arterial blood gas results were reviewed. Mean SaO2 values, Nihon Kohden SpO2 measurements, and Masimo SpO2 measurements were 95.7%, 96.4%, and 96.9%, respectively. The Nihon Kohden SpO2 measurements were less biased than Masimo measurements; their precision was not significantly different. Nihon Kohden and Masimo SpO2 measurements were not significantly different in the “SaO2 < 94%” group (P = 0.083). In the “94% ≤ SaO2 < 98%” and “SaO2 ≥ 98%” groups, there were significant differences between the Nihon Kohden and Masimo SpO2 measurements (P < 0.0001; P = 0.006; respectively). Therefore, when using automatically controlling oxygenation with INTELLiVENT-ASV in mechanically ventilated patients, the Nihon Kohden SpO2 sensor is preferable.Trial registration UMIN000027671. Registered 7 June 2017.


Biofeedback ◽  
2012 ◽  
Vol 40 (4) ◽  
pp. 137-141 ◽  
Author(s):  
Christopher Gilbert

Small pulse oximeters have become widely available and can be useful for noninvasive monitoring of blood oxygen saturation by nonmedical personnel. When training control of breathing, an oximeter helps to reassure clients who hyperventilate that their oxygenation is adequate, offsetting their perception that they are not getting enough air. Low saturation may indicate a medical condition that impairs oxygen absorption. In that case, hyperventilation is a biological compensation that should not be tampered with.


2017 ◽  
Vol 38 (3-4) ◽  
pp. 47
Author(s):  
Lasmida Nazir Nuriman ◽  
Dadang Sjarif Hidajat

There have been controversies over the eiTect of hypertension in pregnancy on the incidence of type I neonatal respiratory distress syndrome or hyaline membrane disease (HMD). We investigated the relationship between the incidence of HMD and maternal hypertension during pregnancy in 91 infants at 34 weeks gestation or less. This retrospective cross sectional study included all live born babies between May 1, 1994 and April 30, 1995 at Dr. Hasan Sadikin General Hospital, Bandung. Maternal hypertension during pregnancy was diagnosed in 38 mothers of91 infants studied. The incidence of HMD (5%) in the maternal hypertension during pregnancy group was significantly lower than the 62% in the normotensive group (p<0.01). There was a negative correlation between the occurence of HMD and hypertension during pregnancy. We conclude that the risk of developing HMD in infants born to hypertensive mothers is significantly lower than those born to normotensive mothers.


2005 ◽  
Vol 18 (5) ◽  
pp. A110-A111
Author(s):  
A LEONE ◽  
C BELLOTTO ◽  
D GIANNINI ◽  
A BALBARINI

1957 ◽  
Vol 51 (6) ◽  
pp. 726-741 ◽  
Author(s):  
Paul Curtis

Sign in / Sign up

Export Citation Format

Share Document