scholarly journals Diagnostic performance of reproducible chest wall tenderness to rule out acute coronary syndrome in acute chest pain: a prospective diagnostic study

BMJ Open ◽  
2015 ◽  
Vol 5 (1) ◽  
pp. e007442-e007442 ◽  
Author(s):  
C. Grani ◽  
O. Senn ◽  
M. Bischof ◽  
P. E. Cippa ◽  
T. Hauffe ◽  
...  
Author(s):  
Eric Durand ◽  
Aurès Chaib ◽  
Etienne Puymirat ◽  
Nicolas Danchin

Patients presenting at the emergency department with acute chest pain and suspected to represent an acute coronary syndrome were classically admitted as routine to the cardiology department, resulting in expensive and time-consuming evaluations. However, 2-5% of patients with acute coronary syndromes were discharged home inappropriately, resulting in increased mortality. To address the inability to exclude the diagnosis of acute coronary syndrome, chest pain units were developed, particularly in the United States. These provide an environment where serial electrocardiograms, cardiac biomarkers, and provocative testing can be performed to confirm or rule out an acute coronary syndrome. Eligible candidates include the majority of patients with non-diagnostic electrocardiograms. The results have been impressive; chest pain units have markedly reduced adverse events, while simultaneously increasing the rate of safe discharge by 36%. Despite evidence to suggest that care in chest pain units is more effective for such patients, the percentage of emergency or cardiology departments setting up chest pain units remains low in Europe.


Author(s):  
Eric Durand ◽  
Aures Chaib ◽  
Nicolas Danchin

Patients presenting at the emergency department with acute chest pain and suspected to represent an acute coronary syndrome were classically admitted as routine to the cardiology department, resulting in expensive and time-consuming evaluations. However, 2-5% of patients with acute coronary syndromes were discharged home inappropriately, resulting in increased mortality. To address the inability to exclude the diagnosis of acute coronary syndrome, chest pain units were developed, particularly in the United States. These provided an environment where serial electrocardiograms, cardiac biomarkers, and provocative testing could be performed to rule out an acute coronary syndrome. Eligible candidates included the majority of patients with non-diagnostic electrocardiograms and normal troponin measurements. The results have been impressive; chest pain units have markedly reduced adverse events, while simultaneously increasing the rate of safe discharge by 36%. Despite evidence to suggest that care in chest pain units is more effective for such patients, the percentage of emergency or cardiology departments setting up chest pain units remains very low in Europe.


Open Heart ◽  
2020 ◽  
Vol 7 (2) ◽  
pp. e001296
Author(s):  
Tonje R Johannessen ◽  
Odd Martin Vallersnes ◽  
Sigrun Halvorsen ◽  
Anne Cecilie K. Larstorp ◽  
Ibrahimu Mdala ◽  
...  

ObjectiveThe European Society of Cardiology 0/1-hour algorithm for high-sensitivity cardiac troponin T (hs-cTnT) has demonstrated high rule-out safety in large hospital validation cohorts. We aimed to validate the algorithm in a primary care setting, where patients have a lower pretest probability for acute coronary syndrome.MethodsThis prospective, observational, diagnostic study included patients with acute non-specific chest pain admitted to a primary care emergency clinic in Oslo, Norway, from November 2016 to October 2018. hs-cTnT was measured after 0, 1 and 4 hours. The primary outcome measure was the diagnostic performance of the 0/1-hour algorithm, the 90-day incidence of AMI or all-cause death the secondary.ResultsAmong 1711 included patients, 61 (3.6%) were diagnosed with AMI. By applying the algorithm, 1311 (76.6%) patients were assigned to the rule-out group. The negative predictive value was 99.9% (95% CI 99.5% to 100.0%), the sensitivity and specificity 98.4% (91.2–100.0) and 79.4% (77.4–81.3), respectively. Sixty-six (3.9%) patients were triaged towards rule-in, where 45 were diagnosed with AMI. The corresponding positive predictive value was 68.2% (58.3–76.7), sensitivity 73.8% (60.9–84.2), and specificity 98.7% (98.1–99.2). Among 334 (19.5%) patients assigned to the observation group in need of further tests, 15 patients had an AMI. The following 90 days, five new patients experienced an AMI and nine patients died, with a low incidence in the rule-out group (0.3%).ConclusionThe 0/1-hour algorithm for hs-cTnT seems safe, efficient and applicable for an accelerated assessment of patients with non-specific chest pain in a primary care emergency setting.Trial registration numberNCT02983123.


Cardiology ◽  
2020 ◽  
pp. 1-8
Author(s):  
Ronny Alcalai ◽  
Boris Varshisky ◽  
Ahmad Marhig ◽  
David Leibowitz ◽  
Larissa Kogan-Boguslavsky ◽  
...  

<b><i>Background:</i></b> Early and accurate diagnosis of acute coronary syndrome (ACS) is essential for initiating lifesaving interventions. In this article, the diagnostic performance of a novel point-of-care rapid assay (SensAheart<sup>©</sup>) is analyzed. This assay qualitatively determines the presence of 2 cardiac biomarkers troponin I and heart-type fatty acid-binding protein that are present soon after onset of myocardial injury. <b><i>Methods:</i></b> We conducted a prospective observational study of consecutive patients who presented to the emergency department with typical chest pain. Simultaneous high-sensitive cardiac troponin T (hs-cTnT) and SensAheart testing was performed upon hospital admission. Diagnostic accuracy was computed using SensAheart or hs-cTnT levels versus the final diagnosis defined as positive/negative. <b><i>Results:</i></b> Of 225 patients analyzed, a final diagnosis of ACS was established in 138 patients, 87 individuals diagnosed with nonischemic chest pain. In the overall population, as compared to hs-cTnT, the sensitivity of the initial SensAheart assay was significantly higher (80.4 vs. 63.8%, <i>p</i> = 0.002) whereas specificity was lower (78.6 vs. 95.4%, <i>p</i> = 0.036). The overall diagnostic accuracy of SensAheart assay was similar to the hs-cTnT (82.7% compared to 76.0%, <i>p</i> = 0.08). <b><i>Conclusions:</i></b> Upon first medical contact, the novel point-of-care rapid SensAheart assay shows a diagnostic performance similar to hs-cTnT. The combination of 2 cardiac biomarkers in the same kit allows for very early detection of myocardial damage. The SensAheart assay is a reliable and practical tool for ruling-in the diagnosis of ACS.


2018 ◽  
Vol 13 (7) ◽  
pp. 1111-1119 ◽  
Author(s):  
Thomas Moumneh ◽  
Vanessa Richard-Jourjon ◽  
Emilie Friou ◽  
Fabrice Prunier ◽  
Caroline Soulie-Chavignon ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document