scholarly journals Comparison of refractive predictability and endothelial cell loss in femtosecond laser-assisted cataract surgery and conventional phaco surgery: prospective randomised trial with 6 months of follow-up

2019 ◽  
Vol 4 (1) ◽  
pp. e000233 ◽  
Author(s):  
Therese Krarup ◽  
Rasmus Ejstrup ◽  
Anouck Mortensen ◽  
Morten la Cour ◽  
Lars Morten Holm

ObjectiveFemtosecond laser-assisted cataract surgery (FLACS) decreases the use of energy and provides a more precise capsulorhexis compared with conventional phaco surgery (CPS). The purpose of this study was to examine if the lower energy use in FLACS caused less endothelial cell loss compared with CPS and if there was a difference in refractive predictability between CPS and FLACS.Methods and analysisThis was a randomised controlled study of 96 patients with a 6-month follow-up comparing one eye surgery by FLACS and the contralateral eye operated by CPS (divide and conquer technique). Both eyes had intraocular aspheric lenses implanted. Uncorrected distance visual acuity, corrected distance visual acuity (CDVA), central corneal endothelial cell count and hexagonality (non-contact endothelial cell microscope) were assessed preoperatively at 40 and at 180 days postoperatively.ResultsThe mean phaco energies were 6.55 (95% CI 5.43 to 7.66) and 9.77 (95% CI 8.55 to 10.95) U/S (p<0.0001) by FLACS and CPS, respectively. At day 40, the mean endothelial cell loss (ECL) was 344 cells/mm2 (95% CI 245 to 443) by FLACS (12.89%) and 497 cells/mm2 (95% CI 380 to 614) by CPS (18.19%) (p=0.027). At day 180, ECL was 362 cells/mm2 (95% CI 275 to 450) in FLACS (13.56%) and 465 cells/mm2 (95% CI 377 to 554) in CPS (17.03%) (p=0.036).The mean absolute difference from the attempted refraction was 0.43 (95% CI 0.36 to 0.51) dioptres (D) at day 40 and 0.46 D (95% CI 0.39 to 0.53) at day 180 by FLACS compared with 0.43 D (95% CI 0.36 to 0.51) at day 40 (p=0.95) and 0.46 D (95% CI 0.37 to 0.52) at day 180 (p=0.91) with CPS.ConclusionECL was significantly lower in FLACS compared with CPS at both day 40 and day 180. ECL was correlated to the energy used. We found no difference in refractive predictability or CDVA between the groups.

2017 ◽  
Vol 2017 ◽  
pp. 1-7 ◽  
Author(s):  
Zi Ye ◽  
Zhaohui Li ◽  
Shouzhi He

Objective. This meta-analysis aimed to compare the outcomes and postoperative complications between femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification cataract surgery (CPCS). Methods. Bibliographic databases, including PubMed, Embase, and Cochrane library, were systematically searched for references on or before September 2015 regarding the outcomes and complications by FLACS or CPCS. Data on corneal endothelial cell loss, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive outcomes, and postoperative complications were retrieved. Results. A total of 9 trials were included in this analysis. Refractive outcomes (MD = −0.21, 95% CI: −0.39~0.03, P=0.02) were significantly improved after FLACS. Although corneal endothelial cell loss was not significantly reduced after FLACS, there was a trend towards lower corneal endothelial cell loss (mean difference (MD) = 197.82, 95% confidence interval (CI): 2.66~392.97, P=0.05) after FLACS. There was no significant difference in UDVA (MD = −0.01, 95% CI: −0.13~0.10, P=0.80) or CDVA (MD = −0.03, 95% CI: 0.07~0.00, P=0.09) between the two surgeries. Elevated intraocular pressure and macular edema were most commonly developed complications after cataract surgery, and the incidence of these complications associated with the two surgeries was similar. Conclusion. Compared with CPCS, FLACS might achieve higher refractive stability and corneal endothelial cell count. Nevertheless, further study is needed to validate our findings.


2021 ◽  
Vol 25 (6) ◽  
pp. 1-68
Author(s):  
Alexander C Day ◽  
Jennifer M Burr ◽  
Kate Bennett ◽  
Rachael Hunter ◽  
Catey Bunce ◽  
...  

Background Cataract surgery is one of the most common operations. Femtosecond laser-assisted cataract surgery (FLACS) is a technique that automates a number of operative steps. Objectives To compare FLACS with phacoemulsification cataract surgery (PCS). Design Multicentre, outcome-masked, randomised controlled non-inferiority trial. Setting Three collaborating NHS hospitals. Participants A total of 785 patients with age-related cataract in one or both eyes were randomised between May 2015 and September 2017. Intervention FLACS (n = 392 participants) or PCS (n = 393 participants). Main outcome measures The primary outcome was uncorrected distance visual acuity in the study eye after 3 months, expressed as the logarithm of the minimum angle of resolution (logMAR): 0.00 logMAR (or 6/6 if expressed in Snellen) is normal (good visual acuity). Secondary outcomes included corrected distance visual acuity, refractive outcomes (within 0.5 dioptre and 1.0 dioptre of target), safety and patient-reported outcome measures at 3 and 12 months, and resource use. All trial follow-ups were performed by optometrists who were masked to the trial intervention. Results A total of 353 (90%) participants allocated to the FLACS arm and 317 (81%) participants allocated to the PCS arm attended follow-up at 3 months. The mean uncorrected distance visual acuity was similar in both treatment arms [0.13 logMAR, standard deviation 0.23 logMAR, for FLACS, vs. 0.14 logMAR, standard deviation 0.27 logMAR, for PCS, with a difference of –0.01 logMAR (95% confidence interval –0.05 to 0.03 logMAR; p = 0.63)]. The mean corrected distance visual acuity values were again similar in both treatment arms (–0.01 logMAR, standard deviation 0.19 logMAR FLACS vs. 0.01 logMAR, standard deviation 0.21 logMAR PCS; p = 0.34). There were two posterior capsule tears in the PCS arm. There were no significant differences between the treatment arms for any secondary outcome at 3 months. At 12 months, the mean uncorrected distance visual acuity was 0.14 logMAR (standard deviation 0.22 logMAR) for FLACS and 0.17 logMAR (standard deviation 0.25 logMAR) for PCS, with a difference between the treatment arms of –0.03 logMAR (95% confidence interval –0.06 to 0.01 logMAR; p = 0.17). The mean corrected distance visual acuity was 0.003 logMAR (standard deviation 0.18 logMAR) for FLACS and 0.03 logMAR (standard deviation 0.23 logMAR) for PCS, with a difference of –0.03 logMAR (95% confidence interval –0.06 to 0.01 logMAR; p = 0.11). There were no significant differences between the arms for any other outcomes, with the exception of the mean binocular corrected distance visual acuity with a difference of –0.02 logMAR (95% confidence interval –0.05 to 0.00 logMAR) (p = 0.036), which favoured FLACS. There were no significant differences between the arms for any health, social care or societal costs. For the economic evaluation, the mean cost difference was £167.62 per patient higher for FLACS (95% of iterations between –£14.12 and £341.67) than for PCS. The mean QALY difference (FLACS minus PCS) was 0.001 (95% of iterations between –0.011 and 0.015), which equates to an incremental cost-effectiveness ratio (cost difference divided by QALY difference) of £167,620. Limitations Although the measurement of outcomes was carried out by optometrists who were masked to the treatment arm, the participants were not masked. Conclusions The evidence suggests that FLACS is not inferior to PCS in terms of vision after 3 months’ follow-up, and there were no significant differences in patient-reported health and safety outcomes after 12 months’ follow-up. In addition, the statistically significant difference in binocular corrected distance visual acuity was not clinically significant. FLACS is not cost-effective. Future work To explore the possible differences in vision in patients without ocular co-pathology. Trial registration Current Controlled Trials ISRCTN77602616. Funding This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 25, No. 6. See the NIHR Journals Library website for further project information. Moorfields Eye Charity (grant references GR000233 and GR000449 for the endothelial cell counter and femtosecond laser used).


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Tommaso Verdina ◽  
Chiara Peppoloni ◽  
Lucrezia Barbieri ◽  
Maria Rosaria Carbotti ◽  
Bruno Battaglia ◽  
...  

Purpose. To evaluate capsulotomy shape and posterior capsule opacification (PCO) during an 18-month follow-up for bimanual femtosecond laser-assisted cataract surgery (FLACS). Methods. 74 eyes operated by a well-trained surgeon with bimanual FLACS technique using low-energy LDV Z8 (Ziemer Ophthalmic Systems AG, Port, Switzerland) were included in the study. The follow-up period was 18 ± 2 months. Another 91 eyes, which underwent standard bimanual microincision cataract surgery (B-MICS), served as a control group. In all cases, a BunnyLens AF (Hanita Lenses, Israel) intraocular lens was implanted in the bag. A digital image of the capsule with slit-lamp retroillumination was performed in all patients at 18 months of follow-up. Image analysis software (ImageJ) was used to evaluate the shape of the capsulotomy in terms of diameter, area, and circularity. PCO score was evaluated using EPCO 2000 software. Best corrected visual acuity (BCVA) and endothelial cell count (ECC) were evaluated before and after surgery at 1 and 18 ± 2 months. Results. At 18 months, mean capsulotomy diameter was 5.34 ± 0.21 mm while capsulorhexis was 5.87 ± 0.37 mm (p<0.001) and the deviation area from baseline was 1.13 ± 1.76 mm2 in FLACS and 2.67 ± 1.69 mm2 in B-MICS (p<0.001). Capsulotomy circularity was 0.94 ± 0.04 while capsulorhexis was 0.83 ± 0.07 (p<0.001). EPCO score was 0.050 ± 0.081 in the FLACS group and 0.122 ± 0.239 in the B-MICS group (p=0.03). The mean BCVA improvement was significant in both groups, without a significant difference at 18 months. We noticed a statistically significant difference in endothelial cell loss at 18 months (FLACS 12.4% and B-MICS 18.1%; p=0.017). Conclusions. Bimanual FLACS is a safe and effective technique, as determined in a long-term follow-up. Capsulotomy shape presented higher stability and circularity in the FLACS group over the 18-month observation period. FLACS resulted in lower PCO scores and endothelial cell loss at 18 months in comparison to B-MICS standard technique.


2016 ◽  
Vol 7 (2) ◽  
pp. 124-134
Author(s):  
Rahul Bhargava ◽  
Shiv Kumar Sharma ◽  
Mini Chandra ◽  
Prachi Kumar ◽  
Yogesh Arora

Introduction: Endothelial cell loss and complications after cataract surgery may be higher when cataract is complicated by uveitis.Objective: To compare endothelial cell damage and complication rates after phacoemulsification and manual small incision cataract surgery (SICS) in patients with uveitis.Materials and methods: Patients with uveitic cataract were randomly allocated for phacoemulsification (n=75) or manual SICS (n=80) in a double blind prospective study. In the bag implantation of a hydrophobic acrylic intraocular lens was aimed in all cases. Patients with follow up of less than six months were excluded. Main outcome measures were alteration in endothelial cell counts (ECC) and morphology, improvement in vision and complication rates. ECC was measured preoperatively and at 1 week, 3 months and six months, postoperatively.Results: Six patients were lost to follow up and another three due inability to implant IOL. There were no significant difference in endothelial cell counts (P= 0.032), the variance of endothelial cell size (CV) and percentage of hexagonal cells between both the groups at six months (Mann-Whitney test, P=0.283). Endothelial cell density was significantly less in the group in which vitrectomy and/or pupil dilatation procedures were performed (2290±31.5 cells/mm2) versus (2385±50.3 cells/mm2), respectively (t test, P<0.001). Incidence of postoperative complications that were observed like persistent uveitis (P=0.591), macular edema (P=0.671) and PCO (P=0.678) and visual outcome (P=0.974) were comparable between the two groups.Conclusions: Manual SICS and phacoemulsification do not differ significantly in endothelial cell loss and complication rates in uveitic eyes. However, increased anterior chamber manoeuvring due to additional procedures may lead to significantly higher endothelial cell loss.


2020 ◽  
pp. bjophthalmol-2019-314548
Author(s):  
Daliya Dzhaber ◽  
Osama M Mustafa ◽  
Fares Alsaleh ◽  
Yassine J Daoud

Background/aimTo compare visual and refractive outcomes, changes in intraocular pressure (IOP), and complications of femtosecond laser-assisted cataract surgery (FLACS) to conventional phacoemulsification surgery (CPS) in paired eyes from the same patients.MethodsThis is a secondary analysis of an intraindividual, randomised, controlled clinical trial including 110 paired eyes from 55 patients that were randomised into either FLACS or CPS groups. Outcomes were recorded at baseline and postoperatively during a 3-month follow-up period.ResultsUncorrected distance visual acuity and corrected distance visual acuity were similar between FLACS and CPS over the follow-up period (p>0.05). The mean absolute refractive error was not significantly different between the two groups at postoperative month 1 (POM1) (0.3±0.2 D in FLACS vs 0.4±0.3 D in CPS, p=0.18) and month 3 (POM3) (0.3±0.3 D in FLACS vs 0.3±0.3 D in CPS, p=0.71). IOP was statistically higher in the FLACS group on postoperative day 1 (20.6±5.7 mm Hg for FLACS and 18.0±4.9 mm Hg for CPS, p=0.01). However, it was similar between the two groups subsequently (p>0.05). Intraoperatively, one case of posterior capsular block syndrome was observed in the FLACS group. Postoperatively, one case of newly developed glaucoma was observed in the FLACS group and one case of retinal tears in the CPS group.ConclusionThe 3-month postoperative refractive and visual outcomes were comparable between FLACS and CPS in paired eyes from the same patients. Complication rate was low in the study population.


2021 ◽  
Vol 8 (2) ◽  
pp. 125-130
Author(s):  
Piotr Kanclerz ◽  
Karolina Pluta

Introduction: Since the introduction, femtosecond laser-assisted cataract surgery (FLACS) was believed to revolutionize cataract surgery. However, the judgment of clinical benefits was found to be far more complex than initially might have been thought. The aim of this review was to analyze the benefits and drawbacks of FLACS compared to traditional phacoemulsification cataract surgery. Results: The benefits of FLACS include lower cumulated phacoemulsification time and endothelial cell loss, perfect centration of the capsulotomy, and the possibility to perform precise femtosecond-assisted arcuate keratotomy incisions. The major disadvantages of FLACS are: high cost of the laser and the disposables for surgery, FLACS-specific intraoperative capsular complications, as well as the risk of intraoperative miosis and the learning curve. Conclusions: FLACS seems to be beneficial in some groups of patients i.e., with low baseline endothelial cell count, or those planning to receive multifocal intraocular lenses. Nevertheless, having considered that the advantages of FLACS might not be clear in every routine case, it cannot be considered as cost-effective.


Sign in / Sign up

Export Citation Format

Share Document