The Woven EndoBridge for unruptured intracranial aneurysms: Results in 95 aneurysms from a single center

2021 ◽  
pp. 159101992110034
Author(s):  
Tom De Beule ◽  
Thierry Boulanger ◽  
Sam Heye ◽  
Williem J van Rooij ◽  
Wim van Zwam ◽  
...  

Background and purpose The Woven EndoBridge (WEB) is an intrasaccular flowdisruptor that is increasingly used for the treatment of (wide-necked) aneurysms. We present our experience with the WEB for unruptured aneurysms. Materials and methods Between April 2014 and August 2019, 93 patients with 95 unruptured aneurysms were primarily treated with the WEB. There were 69 women and 24 men, mean age 61 years (median 58, range 37–80). Results Of 95 aneurysms, 86 had been discovered incidentally, 3 were symptomatic and 6 were additional to another ruptured aneurysm. Location was anterior communicating artery 33, middle cerebral artery 29, basilar tip 19, carotid tip 8, posterior communicating artery 4, posterior inferior cerebellar artery 1, superior cerebellar artery 1. Mean aneurysm size was 6 mm (median 6, range 3–13 mm). In one aneurysm additional coils were used and in another, a stent was placed. There was one procedural rupture without clinical sequelae. There were two thrombo-embolic complications leading to permanent deficit in one patient (mRS 2). Morbidity rate was 1.0% (1 of 93, 95%CI 0.01–6.5%) and mortality was 0% (0 of 93, 95%CI 0.0–4.8%). Angiographic follow-up at six months was available in 85 patients with 87 aneurysms (91%). Of 87 aneurysms, 68 (78%) were completely occluded, 14 (16%) had a neck remnant and 5 were incompletely occluded. Four aneurysms were retreated. Retreatment rate was 4.5% (4 of 87, 95%CI 1.7–13.6%). Conclusion WEB treatment of unruptured aneurysms is safe and effective. Additional devices are needed only rarely and retreatment at follow-up is infrequent.

2018 ◽  
Vol 10 (7) ◽  
pp. 682-686 ◽  
Author(s):  
Matthew J Koch ◽  
Christopher J Stapleton ◽  
Scott B Raymond ◽  
Susan Williams ◽  
Thabele M Leslie-Mazwi ◽  
...  

IntroductionThe LVIS Blue is an FDA-approved stent with 28% metallic coverage that is indicated for use in conjunction with coil embolization for the treatment of intracranial aneurysms. Given a porosity similar to approved flow diverters and higher than currently available intracranial stents, we sought to evaluate the effectiveness of this device for the treatment of intracranial aneurysms.MethodsWe performed an observational single-center study to evaluate initial occlusion and occlusion at 6-month follow-up for patients treated with the LVIS Blue in conjunction with coil embolization at our institution using the modified Raymond–Roy classification (mRRC), where mRRC 1 indicates complete embolization, mRRC 2 persistent opacification of the aneurysm neck, mRRC 3a filling of the aneurysm dome within coil interstices, and mRRC 3b filling of the aneurysm dome.ResultsSixteen aneurysms were treated with the LVIS Blue device in conjunction with coil embolization with 6-month angiographic follow-up. Aneurysms were treated throughout the intracranial circulation: five proximal internal carotid artery (ICA) (ophthalmic or communicating segments), two superior cerebellar artery, two ICA terminus, two anterior communicating artery, two distal middle cerebral artery, one posterior inferior cerebellar artery, and two basilar tip aneurysms. Post-procedurally, there was one mRRC 1 closure, five mRRC 2 closures, and 10 mRRC 3a or 3b occlusion. At follow-up, all the mRRC 1 and mRRC 3a closures, 85% of the mRRC 3b closures and 75% of the mRRC 2 closures were stable or improved to an mRRC 1 or 2 at follow-up.ConclusionsThe LVIS Blue represents a safe option as a coil adjunct for endovascular embolization within both the proximal and distal anterior and posterior circulation.


2018 ◽  
Vol 24 (5) ◽  
pp. 475-481 ◽  
Author(s):  
Sanne BT van Rooij ◽  
Willem Jan van Rooij ◽  
Jo P Peluso ◽  
Menno Sluzewski

Purpose The intrasaccular flow disruptor Woven EndoBridge (WEB) device is developed for the treatment of wide-necked aneurysms without supportive devices. We used the WEB as primary treatment for unruptured aneurysms suitable for the device, regardless of neck size. Methods Between February 2015 and June 2017, 59 aneurysms in 51 patients were selectively treated with the WEB. There were 15 men and 36 women with a mean age of 59 years. Mean aneurysm size was 7.0 mm (range 3–22 mm). Of 59 aneurysms, 45 (76%) had a wide neck defined as ≥4 mm or dome-neck ratio ≤1.5. No stents or supporting balloons were used. Results Initial WEB position was judged good in all 59 unruptured aneurysms. One patient with a basilar tip aneurysm had a late thrombotic posterior cerebral artery occlusion by protrusion of the WEB over the artery. There were no procedural ruptures. Overall complication rate was 2.0% (1 of 51, 95% CI 0.01–11.3%). Imaging follow-up was available in 55 of 59 aneurysms (93%). At 3 months, 41 of 57 aneurysms (72%) were completely occluded, 12 (21%) had a neck remnant and 4 (7%) were incompletely occluded. Conclusion WEB treatment is safe and effective in selected unruptured aneurysms suitable for the device, regardless of neck size or location. There was no need for supportive devices. Three-quarters of all unruptured small aneurysms could be treated with the WEB. In our opinion, the WEB is a valuable alternative to coils, especially in wide-necked aneurysms.


2015 ◽  
Vol 8 (4) ◽  
pp. 386-395 ◽  
Author(s):  
Friedhelm Brassel ◽  
Katharina Melber ◽  
Martin Schlunz-Hendann ◽  
Dan Meila

IntroductionY-configured stent assisted coiling is a promising therapeutic option to ensure safe coil embolization and preserve the affected arteries in complex wide necked aneurysms. We present our experience with self-expanding Acandis Acclino stents for the treatment of complex aneurysms using the kissing-Y technique.MethodsWe retrospectively reviewed seven patients with seven complex aneurysms (three anterior communicating artery (AcomA), two middle cerebral artery, one basilar artery/superior cerebellar artery, and one vertebral artery/posterior inferior cerebellar artery) who were treated with the kissing-Y technique by stent assisted coiling from June 2013 to July 2014, with follow-up until January 2015. DSA follow-up was up to 17 months, with a mean follow-up period of 10 months. Six patients were treated electively and one in the acute phase of a subarachnoid hemorrhage. In all cases, closed cell Acandis Acclino stents were used. We evaluated procedural complications, clinical outcomes, and mid term angiographic follow-up. Additionally, a literature review is provided.ResultsIn all patients, stents were successfully placed and implanted. One patient developed a periprocedural thromboembolic complication not directly related to the stents. No other periprocedural or postprocedural complications were encountered. Follow-up examinations showed stable and total occlusion of all coiled aneurysms.ConclusionsThe results of our study show that the kissing-Y technique using closed cell Acandis Acclino stents followed by coil embolization is a feasible treatment option for selected complex bifurcation aneurysms.


2018 ◽  
Vol 24 (5) ◽  
pp. 489-498 ◽  
Author(s):  
Pervinder Bhogal ◽  
Jorge Chudyk ◽  
Carlos Bleise ◽  
Ivan Lylyk ◽  
Hans Henkes ◽  
...  

Objective The objective of this study was to report our experience on the use of flow diverting stents placed within the posterior inferior cerebellar artery (PICA) as a treatment option for aneurysms of the PICA. Methods Three patients with aneurysms of the PICA, both ruptured and unruptured, underwent treatment of their aneurysms with placement of a single flow diverter in the PICA across the neck of the aneurysm. Adjunctive techniques such as coiling were not used. We present the angiographic and clinical follow-up data. Results The procedure was a technical success in all cases and there were no intraoperative complications. Follow-up data were available for two patients and this showed complete occlusion of the aneurysm with the PICA remaining patent. There was no evidence, either clinical or radiological, of medullary or pontine infarction. One patient died during the follow-up period from an unrelated medical illness (community acquired pneumonia). Conclusion Flow diverters can be successfully placed within the PICA to treat both ruptured and unruptured aneurysms, and they represent an alternative treatment option to endovascular coiling or microscopic neurosurgery.


2021 ◽  
Author(s):  
Daniel M Heiferman ◽  
Jeremy C Peterson ◽  
Kendrick D Johnson ◽  
Vincent N Nguyen ◽  
David Dornbos ◽  
...  

Abstract The Woven EndoBridge (WEB) device (MicroVention, Aliso Viejo, California) is an intrasaccular flow disruptor used for the treatment of both unruptured and ruptured intracranial aneurysms. WEB has been shown to have 54% complete and 85% adequate aneurysm occlusion rates at 1-yr follow-up.1 Residual and recurrent ruptured aneurysms have been shown to have a higher risk of re-rupture than completely occluded aneurysms.2 With increased utilization of WEB in the United States, optimizing treatment strategies of residual aneurysms previously treated with the WEB device is essential, including surgical clipping.3,4 Here, we present an operative video demonstrating the surgical clip occlusion of previously ruptured middle cerebral artery and anterior communicating artery aneurysms that had been treated with the WEB device and had sizable recurrence on follow-up angiography. Informed consent was obtained from both patients. Lessons learned include the following: (1) the WEB device is highly compressible, unlike coils; (2) proximal WEB marker may interfere with clip closure; (3) no evidence of WEB extrusion into the subarachnoid space; (4) no more scarring than expected in ruptured cases; and (5) clipping is a feasible option for treating WEB recurrent or residual aneurysms.


Neurosurgery ◽  
2014 ◽  
Vol 74 (5) ◽  
pp. 482-498 ◽  
Author(s):  
M. Yashar S. Kalani ◽  
Wyatt Ramey ◽  
Felipe C. Albuquerque ◽  
Cameron G. McDougall ◽  
Peter Nakaji ◽  
...  

Abstract BACKGROUND: Given advances in endovascular technique, the indications for revascularization in aneurysm surgery have declined. OBJECTIVE: We sought to define indications, outline technical strategies, and evaluate the outcomes of patients treated with bypass in the endovascular era. METHODS: We retrospectively reviewed all aneurysms treated between September 2006 and February 2013. RESULTS: We identified 54 consecutive patients (16 males and 39 females) with 56 aneurysms. Aneurysms were located along the cervical internal carotid artery (ICA) (n = 1), petrous/cavernous ICA (n = 1), cavernous ICA (n = 16), supraclinoid ICA (n = 7), posterior communicating artery (n = 2), anterior cerebral artery (n = 4), middle cerebral artery (MCA) (n = 13), posterior cerebral artery (PCA) (n = 3), posterior inferior cerebellar artery (n = 4), and vertebrobasilar arteries (n = 5). Revascularization was performed with superficial temporal artery (STA) to MCA bypass (n = 25), STA to superior cerebellar artery (SCA) (n = 3), STA to PCA (n = 1), STA-SCA/STA-PCA (n = 1), occipital artery (OA) to PCA (n = 2), external carotid artery/ICA to MCA (n = 15), OA to MCA (n = 1), OA to posterior inferior cerebellar artery (n = 1), and in situ bypasses (n = 8). At a mean clinical follow-up of 18.5 months, 45 patients (81.8%) had a good outcome (Glasgow Outcome Scale 4 or 5). There were 7 cases of mortality (12.7%) and an additional 9 cases of morbidity (15.8%). At a mean angiographic follow-up of 17.8 months, 14 bypasses were occluded. Excluding the 7 cases of mortality, the majority of aneurysms (n = 42) were obliterated. We identified 7 cases of residual aneurysm and recurrence in 6 patients at follow-up. CONCLUSION: Given current limitations with existing treatments, cerebral revascularization remains an essential technique for aneurysm surgery.


Neurosurgery ◽  
2020 ◽  
Vol 87 (1) ◽  
pp. E16-E22 ◽  
Author(s):  
Fadi Al Saiegh ◽  
David Hasan ◽  
Nikolaos Mouchtouris ◽  
Mario Zanaty ◽  
Ahmad Sweid ◽  
...  

Abstract BACKGROUND Coil embolization of ruptured bifurcation aneurysms is challenging and often necessitates adjunctive stenting, which requires antiplatelet therapy in the setting of subarachnoid hemorrhage (SAH). The Woven EndoBridge (WEB; Terumo) device is an alternative self-expanding 3D mesh that does not require antiplatelet agents. However, its use has been mostly reserved for unruptured aneurysms. OBJECTIVE To assess the safety and feasibility of ruptured aneurysm treatment with the WEB. METHODS Retrospective analysis of 9 SAH patients with 11 aneurysms that were treated with the WEB device at 2 institutions after FDA approval. RESULTS Hunt and Hess grades were III and IV in 4 (44%) each and V in 1 (11%). All patients were treated within 24 h of hospitalization, and a single WEB was used in all but one aneurysm. Aneurysms treated were 3 basilar tip, 2 anterior communicating artery, 2 posterior inferior cerebellarartery, 1 middle cerebral artery, 1 carotid-ophthalmic artery, 1 posterior communicating artery, and 1 vertebrobasilar junction. Mean aneurysm height and width were 6.2 ± 2.2 mm (range: 3-10) and 5.6 ± 3.0 mm (range: 3.3-14), respectively. Mean dome-to-neck ratio was 1.7 ± 0.8 (range: 1.0-3.8). There was one intraoperative rupture that occurred because of device dislodgement and was managed with embolization. There were no treatment-related mortalities and no re-rupture after securement of the aneurysms with the WEB. CONCLUSION Our preliminary experience indicates that the WEB device can be used safely for ruptured aneurysms of various sizes in the anterior and posterior circulation. Larger series with long-term follow-up are necessary to confirm our findings.


2020 ◽  
pp. neurintsurg-2020-016405 ◽  
Author(s):  
Patrick P Youssef ◽  
David Dornbos III ◽  
Jeremy Peterson ◽  
Ahmad Sweid ◽  
Amanda Zakeri ◽  
...  

BackgroundWide-necked bifurcation aneurysms (WNBAs) present unique challenges for endovascular treatment. The Woven EndoBridge (WEB) device is an intrasaccular braided device, recently approved by the FDA for treatment of WNBAs. While treatment of intracranial aneurysms with the WEB device has been shown to yield an adequate occlusion rate of 85% at 1 year, few data have been published for patients with ruptured aneurysms.ObjectiveTo present a multi-institutional series depicting the safety and efficacy of using the WEB device as the primary treatment modality in ruptured intracranial aneurysms.MethodsA multi-institutional retrospective analysis was conducted, assessing patients presenting with aneurysmal subarachnoid hemorrhage treated with the WEB between January 2014 and April 2020. Baseline demographics, aneurysm characteristics, adverse events, and long-term outcomes (occlusion, re-treatment, functional status) were collected. A descriptive analysis was performed, and variables potentially associated with aneurysm recurrence or re-treatment were assessed.ResultsForty-eight patients were included. Anterior communicating artery aneurysms were the most common (35.4%) location for treatment, followed by middle cerebral artery (20.8%) and basilar apex (16.7%). Procedural success was noted in 95.8% of patients, and clinically significant periprocedural adverse events occurred in 12.5%. After a median follow-up of 5.5 months, 54.2% of patients had follow-up angiographic imaging. Complete occlusion was seen in 61.5% of cases with adequate occlusion in 92.3%. Re-treatment was required in only 4.2% of patients during the study period. Tobacco use was significantly higher in patients with aneurysm recurrence (88.9% vs 35.7%; p=0.012). No other characteristics were associated with recurrence/re-treatment. At 30 days, 81.1% were functionally independent (modified Rankin Scale score ≤2).ConclusionTreatment of acutely ruptured aneurysms with the WEB device demonstrates both safety and efficacy on par with rates of conventional treatment strategies.


2020 ◽  
pp. 159101992096834
Author(s):  
Nicolas K Khattar ◽  
Andrew C White ◽  
Aurora S Cruz ◽  
Shawn W Adams ◽  
Kimberly S Meyer ◽  
...  

Ruptured vertebrobasilar dissecting aneurysms require urgent, often challenging treatment as they have with a high re-hemorrhage rate within the first 24 hours. The patient is a 57-year-old woman who presented with severe-sudden onset headache. Further work up showed a ruptured dissecting aneurysm of the caudal loop of the posterior inferior cerebellar artery (PICA) with associated narrowing distally, in the ascending limb. The aneurysm was immediately occluded with a Woven Endobridge (WEB) device (MicroVention, Tustin, CA, USA) while flow diversion treatment of the diseased ascending limb was postponed. Follow-up angiography three months later showed complete occlusion of the aneurysm, as well as healing of the diseased distal vessel, obviating the need for further intervention. WEB embolization of a ruptured dissecting posterior circulation aneurysm provided an excellent outcome for this patient.


2021 ◽  
pp. 1-7
Author(s):  
Nikolaos Mouchtouris ◽  
David Hasan ◽  
Edgar A. Samaniego ◽  
Fadi Al Saiegh ◽  
Ahmad Sweid ◽  
...  

OBJECTIVE Wide-neck bifurcation cerebral aneurysms have historically required either clip ligation or stent- or balloon-assisted coil embolization. This predicament led to the development of the Woven EndoBridge (WEB) aneurysm embolization system, a self-expanding mesh device that achieves intrasaccular flow disruption and does not require antithrombotic medications. The authors report their operative experience and 6-month follow-up occlusion outcomes with the first 115 aneurysms they treated via WEB embolization. METHODS The authors reviewed the first 115 cerebral aneurysms they treated by WEB embolization after FDA approval of the WEB embolization device (from February 2019 to January 2021). Data were collected on patient demographics and clinical presentation, aneurysm characteristics, procedural details, postembolization angiographic contrast stasis, and functional outcomes. RESULTS A total of 110 patients and 115 aneurysms were included in our study (34 ruptured and 81 unruptured aneurysms). WEB embolization was successful in 106 (92.2%) aneurysms, with a complication occurring in 6 (5.5%) patients. Contrast clearance was seen in the arterial phase in 14 (12.2%) aneurysms, in the capillary phase in 16 (13.9%), in the venous phase in 63 (54.8%), and no contrast was seen in 13 (11.3%) of the aneurysms studied. Follow-up angiography was performed on 60 (52.6%) of the aneurysms, with complete occlusion in 38 (63.3%), neck remnant in 14 (23.3%), and aneurysmal remnant in 8 (13.3%). Six (5.5%) patients required re-treatment for persistent aneurysmal residual on follow-up angiography. CONCLUSIONS The WEB device has been successfully used for the treatment of both unruptured and ruptured wide-neck bifurcation aneurysms by achieving intrasaccular flow diversion. Here, the authors have shared their experience with its unique technical considerations and device size selection, as well as critically reviewed complications and aneurysm occlusion rates.