Single-center experience with the Tigertriever device for the recanalization of large vessel occlusions in acute ischemic stroke

2018 ◽  
Vol 11 (5) ◽  
pp. 455-459 ◽  
Author(s):  
Batuhan Kara ◽  
Hatem Hakan Selcuk ◽  
Aysun Erbahceci Salik ◽  
Hasanagha Zalov ◽  
Omer Yildiz ◽  
...  

BackgroundTigertriever (Rapid Medical, Yoqneam, Israel) is a new design of stent retriever.PurposeTo evaluate the feasibility, safety, and efficacy of the Tigertriever in patients with acute ischemic stroke who have undergone mechanical thrombectomy.Materials and methodsTwo different techniques—namely, standard unsheathing (SUT) and repetitive inflation-deflation (RID) techniques, were used. Modified Thrombolysis in Cerebral Infarction (mTICI) scores of 2b and 3 were considered as successful recanalization.ResultsA total of 61 thrombectomy procedures with Tigertriever were retrospectively evaluated. The mean age of patients was 60.7 years and their National Institutes of Health Stroke Scale score was 14.7. Overall, the percentage of patients with a mTICI score of 0, 2b, and 3 was 24.6, 26.2, and 49.2, respectively. Successful recanalization and first-pass success rates were 75.4% and 37.7%, respectively. There were no statistical differences between the results of the SUT and RID techniques. No vessel rupture, dissection, or device detachment was observed. The number of patients with a good clinical outcome (modified Rankin Scale score 0–2) was 17 (27.9%).ConclusionOur results showed that the Tigertriever device is safe and efficient for mechanical thrombectomy.

BMC Neurology ◽  
2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Amre Nouh ◽  
Tapan Mehta ◽  
Mohamed Hussain ◽  
Xianyuan Song ◽  
Martin Ollenschleger

Abstract Background A number of emerging studies have evaluated clot composition in acute ischemic stroke. Studies of clot composition of embolic strokes of undetermined strokes are lacking. Objectives We sought to analyze the RBC to platelet ratios in clots and correlated our findings with stroke etiology. Methods This was a prospective study analyzing clots retrieved by mechanical thrombectomy in acute ischemic stroke patients at our institution. All clots were stained and scanned at 200x magnification by using a Scanscope XT digital scanner (Apergio, Vista, California). Image-J software (National Institutes of Health, Bethesda, Maryland) was used for semi quantitative analysis of percentage RBC’s and platelets. Unpaired t-test was used to compare means of RBC to Platelet ratios. Correlation of RBC to Platelet ratios with stroke etiology was performed. Results A total of 33 clots from 33 patients were analyzed. Stroke etiology was undetermined in 6 patients, cardioembolic in 14, large vessel atherosclerosis (LVA) in 9, and carotid dissection in 4. The mean RBC to platelet ratio was 0.78:1 (+/− 0.65) in cardioembolic clots, 1.73:1 (+/− 2.38) in LVA and 1.4:1(+/− 0.70) in carotid dissections. Although patients with undetermined etiology had a similar clot composition to cardioembolic stroke (0.36:1+/− 0.33), (p = 0.19), it differed significantly from LVA and dissections respectively (p = 0.037, p = 0.01). Conclusion In our study, a low RBC to Platelet ratio was found among patients with embolic strokes of undetermined source, however shared similar characteristics with cardioembolic thrombi. Ongoing collection and analysis is needed to confirm these findings and its significance in evaluating stroke etiology.


2016 ◽  
Vol 9 (6) ◽  
pp. 541-546 ◽  
Author(s):  
Anna Luisa Kühn ◽  
Ajay K Wakhloo ◽  
J Diego Lozano ◽  
Francesco Massari ◽  
Katyucia De Macedo Rodrigues ◽  
...  

ObjectiveTo evaluate the safety and efficacy of the ‘Baby Trevo’ (Trevo XP ProVue 3×20 mm Retriever) stent retriever for large vessel occlusions (LVOs) in acute ischemic stroke (AIS).Materials and methodsWe retrospectively analyzed our stroke database and included all patients treated with the Baby Trevo for distal LVOs in AIS. Patient gender, mean age, vascular risk factors, National Institutes of Health Stroke Scale (NIHSS) score at presentation, and modified Rankin Scale (mRS) score at baseline and 90-day follow-up were documented. Reperfusion rates for the vessels treated were recorded using the Thrombolysis in Cerebral Infarction (TICI) classification. Occurrence of vasospasm and new or evolving infarcts in the treated vascular territory was documented.ResultsThirty-five subjects with a mean NIHSS score of 18 were included. The Baby Trevo device was used in 38 branches of the anterior and posterior circulations. TICI 2b/3 blood flow was restored after one single pass in 20/38 (52.6%) and after two or three passes in 11 vessels. The remaining vessels required either more than three passes, showed less than a TICI 2b/3 reperfusion (n=3), or demonstrated failure to retrieve the clot (n=4). TICI 2b/3 reperfusion was achieved in 30 patients (85.7%). No vessel injuries, rupture, or significant vasospasm were seen. Overall, a mRS score of ≤2 was seen in 56.5% of the subjects successfully treated with the Baby Trevo at 90 days and in 81.3% of surviving patients; seven patients died (20%).ConclusionsOur preliminary data suggest that the ‘Baby Trevo’ achieves a high recanalization rate without any significant risk. Larger cohort studies are needed to validate the clinical benefit.


2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
Sascha Prothmann ◽  
Hannah Lockau ◽  
Franziska Dorn ◽  
Holger Poppert ◽  
Annette Förschler ◽  
...  

Purpose. We analyzed our experience with the phenox clot retriever as part of a multimodal mechanical thrombectomy (MTE) approach in acute ischemic stroke.Methods. 56 patients were treated by MTE with the phenox clot retriever alone or in combination with other modalities.Results. Overall we achieved TICI 2b/3 reperfusion rates of 61,9%. In multimodally treated patients we achieved reperfusion rates of 72,8%. There were 3 (5,5%) severe adverse events, all symptomatic intracranial hemorrhages. The mean angio to reperfusion times (ART) were 74 minutes for phenox-only procedures and 51 minutes for multimodal procedures. A chronological analysis showed a reduction of ART from 70,5 to 49,4 minutes and an increase of TICI 2b/3 recanalizations from 53,8% to 81,8%. Throughout the observation period there was a significant shift towards multimodal procedures with simultaneous increase of TICI 2b/3 reperfusions. Both effects are partially attributable to our institutional learning curve. NIHSS improvement could be seen in 54% () overall and in 73% () of MCA recanalizations.Conclusions. The phenox clot retriever is a safe and effective tool for MTE in acute stroke patients, with faster and better reperfusion results when used as part of a multimodal strategy. Clinical improvement is more frequent in MCA recanalizations.


2019 ◽  
Vol 23 (3) ◽  
pp. 363-368 ◽  
Author(s):  
Bing Zhou ◽  
Xiao-Chuan Wang ◽  
Jun-Yi Xiang ◽  
Ming-Zhao Zhang ◽  
Bo Li ◽  
...  

OBJECTIVEMechanical thrombectomy using a Solitaire stent retriever has been widely applied as a safe and effective method in adult acute ischemic stroke (AIS). However, due to the lack of data, the safety and effectiveness of mechanical thrombectomy using a Solitaire stent in pediatric AIS has not yet been verified. The purpose of this study was to explore the safety and effectiveness of mechanical thrombectomy using a Solitaire stent retriever for pediatric AIS.METHODSBetween January 2012 and December 2017, 7 cases of pediatric AIS were treated via mechanical thrombectomy using a Solitaire stent retriever. The clinical practice, imaging, and follow-up results were reviewed, and the data were summarized and analyzed.RESULTSThe ages of the 7 patients ranged from 7 to 14 years with an average age of 11.1 years. The preoperative National Institutes of Health Stroke Scale (NIHSS) scores ranged from 9 to 22 with an average of 15.4 points. A Solitaire stent retriever was used in all patients, averaging 1.7 applications of thrombectomy and combined balloon dilation in 2 cases. Grade 3 on the modified Thrombolysis In Cerebral Infarction scale of recanalization was achieved in 5 cases and grade 2b in 2 cases. Six patients improved and 1 patient died after thrombectomy. The average NIHSS score of the 6 cases was 3.67 at discharge. The average modified Rankin Scale score was 1 at the 3-month follow-up. Subarachnoid hemorrhage after thrombectomy occurred in 1 case and that patient died 3 days postoperatively.CONCLUSIONSThis study shows that mechanical thrombectomy using a Solitaire stent retriever has a high recanalization rate and excellent clinical prognosis in pediatric AIS. The safety of mechanical thrombectomy in pediatric AIS requires more clinical trials for confirmation.


Neurosurgery ◽  
2004 ◽  
Vol 54 (1) ◽  
pp. 218-223 ◽  
Author(s):  
Mark R. Harrigan ◽  
Elad I. Levy ◽  
Bernard R. Bendok ◽  
L. Nelson Hopkins

Abstract OBJECTIVE AND IMPORTANCE Intra-arterial thrombolysis has been demonstrated to improve recanalization and outcomes among patients with acute ischemic stroke. However, thrombolytic agents have limited effectiveness and are associated with a significant risk of bleeding. Bivalirudin is a direct thrombin inhibitor that has been demonstrated in the cardiology literature to have a more favorable efficacy and bleeding profile than other antithrombotic medications. We report the use of bivalirudin during endovascular treatment of acute stroke, when hemorrhagic complications are not uncommon. CLINICAL PRESENTATION A 71-year-old woman with atrial fibrillation presented with right hemiparesis and aphasia and was found to have a National Institutes of Health Stroke Scale score of 10. Computed tomographic scans revealed no evidence of intracranial hemorrhage, aneurysm, or ischemic stroke. Cerebral angiography revealed thromboembolic occlusion of the superior division of the left middle cerebral artery. INTERVENTION For anticoagulation, a loading dose of bivalirudin was intravenously administered before the interventional procedure, followed by continuous infusion. Attempts to remove the clot with an endovascular snare failed to induce recanalization of the vessel. Bivalirudin was then administered intra-arterially. Immediate postprocedural angiography demonstrated restoration of flow in the left middle cerebral artery. Repeat computed tomographic scans demonstrated no intracranial hemorrhage. The patient's hemiparesis and aphasia were nearly resolved and her National Institutes of Health Stroke Scale score was 2 at the time of her discharge 5 days later. CONCLUSION To our knowledge, this is the first report of the use of bivalirudin for treatment of acute ischemic stroke. Bivalirudin may be a useful agent for intravenous anticoagulation and intra-arterial thrombolysis in this setting.


Stroke ◽  
2017 ◽  
Vol 48 (suppl_1) ◽  
Author(s):  
Ganesh Asaithambi ◽  
Amy L Castle ◽  
Lana J Stein ◽  
Sandra K Hanson ◽  
Jeffrey P Lassig

Background: Recent endovascular stroke studies utilizing primarily stent retrievers have proven clinical benefit among eligible patients. It remains unclear if this benefit is exclusive to stent retrievers. We present the results of a single-center experience for patients undergoing primary aspiration thrombectomy for acute ischemic stroke (AIS). Methods: A retrospective analysis of all AIS patients receiving primary aspiration thrombectomy from January 2014 to March 2016 was performed. We assessed stroke severity at admission and discharge as defined by the National Institutes of Health Stroke Scale score (NIHSSS), median onset to puncture and onset to recanalization times, location of target vessel treated, rate of concurrent intravenous (IV) alteplase use, and rate of TICI 2b/3 reperfusion. Outcomes adjudicated included rates of symptomatic intracerebral hemorrhage (sICH), favorable discharge disposition to home, and 90-day modified Rankin Scale (mRS) score ≤2. Results: During the study period, 121 patients (mean age 68.7±16.5 years, 53.7% women) received primary aspiration thrombectomy for 124 occlusions (26% terminal internal carotid artery, 45% M1, 15% M2, 11% basilar artery, 3% other). Median admission NIHSSS was 19 [11, 22] and improved to 6 [1, 15] upon discharge. Median onset to puncture and onset to recanalization times were 258 [148, 371] and 300 [180, 409] minutes, respectively. The rate of TICI 2b/3 reperfusion was 84.7%, and 52% received adjunctive IV alteplase. Rates of favorable discharge to home was 28.9% and 90-day mRS ≤2 was 39.8%. Only one patient developed sICH. Conclusion: Our single-center experience shows that primary aspiration thrombectomy can yield both favorable angiographic and clinical outcomes with minimal adverse effect.


2012 ◽  
Vol 60 (4) ◽  
pp. 406
Author(s):  
Manish Shrivastava ◽  
Darshana Sanghvi ◽  
Shirish Hastak ◽  
Sourabh Lahoti ◽  
Annu Aggarwal

Narra J ◽  
2021 ◽  
Vol 1 (3) ◽  
Author(s):  
Rizky Sarengat ◽  
Mohammad S. Islam ◽  
Mohammad S. Ardhi

The coronavirus disease 2019 (COVID-19) pandemic has caused millions of deaths worldwide. Acute ischemic stroke is a life-threatening risk factor for COVID-19 infection. Neutrophil-to-lymphocyte ratio (NLR) is one of the predictors of poor prognosis in acute ischemic stroke. The aim of this study was to assess the correlation between NLR values and the clinical outcome of acute thrombotic stroke patients with COVID-19 that was measured using the National Institutes of Health Stroke Scale (NIHSS). A cross-sectional hospital-based study was conducted in Dr. Soetomo General Hospital Surabaya, Indonesia. Patients with acute thrombotic stroke and COVID-19 admitted between 1 March 2020 and 31 May 2021 were recruited. The NLR values and the NIHSS scores were assessed during the admission and the correlation between NLR and NIHSS scores was calculated. This study included 21 patients with acute thrombotic stroke and COVID-19, consisting of 12 males and 9 females. The mean age was 57.6 years old. The mean NLR values was 8.33±6.7 and the NIHSS scores ranging from 1 to 33. Our data suggested a positive correlation between NLR values and NIHSS scores, r=0.45 with p=0.041. In conclusion, the NLR value is potentially to be used as a predictor of the clinical outcome in acute thrombotic stroke patients with COVID-19. However, further study is warranted to validate this finding.


Sign in / Sign up

Export Citation Format

Share Document