THz Spectroscopic Imaging of Chemicals Using IS-TPG

2016 ◽  
Vol 25 (03n04) ◽  
pp. 1640016
Author(s):  
Kosuke Murate ◽  
Mikiya Kato ◽  
Kodo Kawase

In 2003, we demonstrated a non-destructive terahertz spectroscopic imaging of illicit drugs hidden in envelopes using a widely tunable THz-wave parametric source, though its dynamic range at that time was less than four orders. Recently, we have realized more than nine orders of dynamic range with an evolved injection seeded THz-wave spectrometer. Now we can detect drugs under much thicker obstacles than before. In this report, we introduce the result of THz spectroscopic imaging of chemicals under thick envelopes and related topics; Enhanced tuning range of is-TPG up to 5 THz and >90 dB dynamic range THz spectroscopic system.

Author(s):  
Rieko Mizuuchi ◽  
Yuji Hisazato ◽  
Hiroaki Cho ◽  
Yusuke Nakamura ◽  
Yuichi Sumimoto ◽  
...  

Micromachines ◽  
2021 ◽  
Vol 12 (6) ◽  
pp. 635
Author(s):  
Chih-Hsuan Lin ◽  
Chao-Hung Song ◽  
Kuei-Ann Wen

In this study, a multi-function microelectromechanical system (MEMS) was integrated with a MEMS oscillator, using the resonant frequency oscillation characteristics of the oscillator to provide the Lorentz current of the magnetometer to enhance a large dynamic range of reading, which eliminates the off-chip clock and current generator. The resonant frequency can be adjusted by adjusting the bias voltage of the oscillator to further adjust the sensitivity of the magnetometer. With the mechanical Q value characteristic, a great dynamic range can be achieved. In addition, using the readout circuit of the nested chopper and correlated double-sampling (CDS) to reduce the noise and achieve a smaller resolution, the calibration circuit compensates for errors caused by the manufacturing process. The frequency of the tuning range of the proposed structure is 17,720–19,924 Hz, and the tuning range of the measurement result is 110,620.36 ppm. The sensitivities of the x-, y-, and z-axes of the magnetometer with driving current of 2 mA are 218.3, 74.33, and 7.5 μV/μT for ambient pressure of 760 torr. The resolutions of the x-, y-, and z-axes of the magnetometer with driving current of 2 mA are 3.302, 9.69, and 96 nT/√Hz for ambient pressure of 760 torr.


2016 ◽  
Vol 82 (3) ◽  
pp. 217-220
Author(s):  
Ryo YAMAZAKI ◽  
Mikiya KATO ◽  
Kosuke MURATE ◽  
Kazuki IMAYAMA ◽  
Kodo KAWASE

2003 ◽  
Vol 11 (20) ◽  
pp. 2549 ◽  
Author(s):  
Kodo Kawase ◽  
Yuichi Ogawa ◽  
Yuuki Watanabe ◽  
Hiroyuki Inoue

Sign in / Sign up

Export Citation Format

Share Document