Thermodynamic Evaluation of a Direct Expansion Ground-Sourced Heat Pump with Horizontal Ground Heat Exchangers Using Advanced Exergy Analysis

Author(s):  
Abdolazim Zarei ◽  
Mehran Ameri ◽  
Hossein Ghazizade-Ahsaee

This paper deals with the advanced exergetic analysis of a horizontal direct-expansion ground sourced CO2 heat pump operating in a transcritical cycle. The cycle is thermodynamically modeled in Engineering Equation Solver (EES) considering the pressure drops in both high and low temperature heat exchangers, and the system is to provide a fixed heating load. Conventional exergy analysis orderly suggests a compressor, expansion valve, gas cooler and ground heat exchanger to be considered for system improvement, while tracing exergy destruction of all components in detail demonstrates true improvement potential of each and all components and the system as a whole and offers a different order. Advanced exergy analysis points out that the compressor is directly and indirectly responsible for 56% of the overall exergy destruction generated in the cycle, confirming the detrimental role of this component in the system. The second influential component is recognized to be a ground heat exchanger accounting for 20% exergy destruction of the compressor as well as submitting 89% avoidability in its own exergy destruction, and expansion valve proves to be the last option for system improvement according to this analysis.

2014 ◽  
Vol 35 (1) ◽  
pp. 77-86 ◽  
Author(s):  
Robert Sekret ◽  
Anna Nitkiewicz

Abstract Exergy analysis of low temperature geothermal heat plant with compressor and absorption heat pump was carried out. In these two concepts heat pumps are using geothermal water at 19.5 oC with spontaneous outflow 24 m3/h as a heat source. The research compares exergy efficiency and exergy destruction of considered systems and its components as well. For the purpose of analysis, the heating system was divided into five components: geothermal heat exchanger, heat pump, heat distribution, heat exchanger and electricity production and transportation. For considered systems the primary exergy consumption from renewable and non-renewable sources was estimated. The analysis was carried out for heat network temperature at 50/40 oC, and the quality regulation was assumed. The results of exergy analysis of the system with electrical and absorption heat pump show that exergy destruction during the whole heating season is lower for the system with electrical heat pump. The exergy efficiencies of total system are 12.8% and 11.2% for the system with electrical heat pump and absorption heat pump, respectively.


2021 ◽  
pp. 311-311
Author(s):  
Fakhrodin Jovijari ◽  
Abbas Kosarineia ◽  
Mehdi Mehrpooya ◽  
Nader Nabhani

Energy quality in each country is one of the important indicators of economic development, Which affects the economic growth of that country. Exergy analysis, considering all flow properties including pressure, temperature, composition, is a powerful way to evaluate the energy consumption of equipment such as natural gas and liquefied gas plants. Inefficiency of a system can be defined by the conventional exergy analysis method, While, irreversible resources and real potentials for system improvement can only be identified by the advanced exergy analysis method. This analysis splits conventional exergy destruction into two exogenous and endogenous parts according to origin, and also unavoidable and avoidable parts according to the ability to remove and modifications. In this method, the exergy concept was separated by considering the ideal and avoidable condition assumptions. As a real case study, a natural gas liquid plant 800, from National Iranian South Oil Company located in southwest of Iran was considered to be investigated by conventional exergy analysis, advanced exergy analysis methods. The results of conventional exergy analysis illustrated that the highest amount of exergy destruction belonged to compressor and heat exchanger with 509.99 and 629.04 kW, respectively. However, in the case of heat exchanger, despite having the highest rate of exergy destruction, it is not considered in modification priorities due to its low avoidable exergy destruction value. Also, advanced exergy analysis suggested that the exergy destruction of the compressor and heat exchanger will be reduced by improving performance of these components.


Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1893
Author(s):  
Kwonye Kim ◽  
Jaemin Kim ◽  
Yujin Nam ◽  
Euyjoon Lee ◽  
Eunchul Kang ◽  
...  

A ground source heat pump system is a high-performance technology used for maintaining a stable underground temperature all year-round. However, the high costs for installation, such as for boring and drilling, is a drawback that prevents the system to be rapidly introduced into the market. This study proposes a modular ground heat exchanger (GHX) that can compensate for the disadvantages (such as high-boring/drilling costs) of the conventional vertical GHX. Through a real-scale experiment, a modular GHX was manufactured and buried at a depth of 4 m below ground level; the heat exchange rate and the change in underground temperatures during the GHX operation were tracked and calculated. The average heat exchanges rate was 78.98 W/m and 88.83 W/m during heating and cooling periods, respectively; the underground temperature decreased by 1.2 °C during heat extraction and increased by 4.4 °C during heat emission, with the heat pump (HP) working. The study showed that the modular GHX is a cost-effective alternative to the vertical GHX; further research is needed for application to actual small buildings.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3511
Author(s):  
Ali Khalid Shaker Al-Sayyab ◽  
Joaquín Navarro-Esbrí ◽  
Victor Manuel Soto-Francés ◽  
Adrián Mota-Babiloni

This work focused on a compound PV/T waste heat driven ejector-heat pump system for simultaneous data centre cooling and waste heat recovery for district heating. The system uses PV/T waste heat as the generator’s heat source, acting with the vapour generated in an evaporative condenser as the ejector drive force. Conventional and advanced exergy and advanced exergoeconomic analyses are used to determine the cause and avoidable degree of the components’ exergy destruction rate and cost rates. Regarding the conventional exergy analysis for the whole system, the compressor represents the largest exergy destruction source of 26%. On the other hand, the generator shows the lowest sources (2%). The advanced exergy analysis indicates that 59.4% of the whole system thermodynamical inefficiencies can be avoided by further design optimisation. The compressor has the highest contribution to the destruction in the avoidable exergy destruction rate (21%), followed by the ejector (18%) and condenser (8%). Moreover, the advanced exergoeconomic results prove that 51% of the system costs are unavoidable. In system components cost comparison, the highest cost comes from the condenser, 30%. In the same context, the ejector has the lowest exergoeconomic factor, and it should be getting more attention to reduce the irreversibility by design improving. On the contrary, the evaporator has the highest exergoeconomic factor (94%).


2013 ◽  
Vol 724-725 ◽  
pp. 909-915
Author(s):  
Ping Fang Hu ◽  
Zhong Yi Yu ◽  
Fei Lei ◽  
Na Zhu ◽  
Qi Ming Sun ◽  
...  

A vertical U-tube ground heat exchanger can be utilized to exchange heat with the soil in ground source heat pump systems. The outlet temperature of the working fluid through the U-tube not only accounts for heat transfer capacity of a ground heat exchanger, but also greatly affects the operational efficiency of heat pump units, which is an important characteristic parameter of heat transfer process. It is quantified by defining a thermal effectiveness coefficient. The performance evaluation is performed with a three dimensional numerical model using a finite volume technique. A dynamic simulation was conducted to analyze the thermal effectiveness as a function of soil thermal properties, backfill material properties, separation distance between the two tube legs, borehole depth and flow velocity of the working fluid. The influence of important characteristic parameters on the heat transfer performance of vertical U-tube ground heat exchangers is investigated, which may provide the references for the design of ground source heat pump systems in practice.