Outcomes of the Hemi-Hamatum Arthroplasty

2019 ◽  
Vol 24 (03) ◽  
pp. 342-346
Author(s):  
Karlis Verdins ◽  
Vadims Nefjodovs

Background: Multi-fragmental intra-articular middle phalanx base fractures mostly occur in young adults during sports or work-related activities. If left untreated properly proximal interphalangeal joint (PIPJ) instability and pain persists, thus impairing the hand’s function and the patient’s quality of life. Joint surface reconstruction with hamate osteochondral graft can be used for multi-fragmental middle phalanx base reconstruction. Methods: A retrospective study was conducted. The technique was used for 17 patients. Follow-up was performed at least 6 months after the surgery. Patients were asked to fulfil multiple surveys: Disabilities of the Arm, Shoulder and Hand (DASH), Patient-Rated Wrist Evaluation (PRWE) and Modern Activity Subjective Survey 2007 (MASS07). Objective measurements included strength of the power and pinch grip, range of motions (ROM) in both proximal interphalangeal and distal interphalangeal (DIPJ) joints. All measurements were taken on both hands, on operated and contralateral fingers. Results: Out of 17 patients 5 were females and 12 males, mean age 40 (ranged 22-65 years) Eleven patients agreed to participate in the follow-up. All patients were right-handed, 8 patients had injured their right hand. The injuries’ aetiologies were sports (n = 3), fighting (n = 2) and work-related (n = 4). Six patients were treated with immobilisation before the surgery, which was performed on average 45 days after the injury (ranged 1–184 days). Two patients developed arthrosis post-operatively and received synthetic joints. Mean DASH score was 6.9, PRWE score was 5.2 and mean MASS07 score was 6.8. Patients achieved on average 90% of power grip and 100% of pinch grip with their injured hand compared to their healthy hand. Average ROM in PIPJ was 82.2° and in DIPJ 68.9°. No patients experienced joint instability or chronic pain. Conclusions: Hemi-hamate arthroplasty provides satisfactory results in patients with both acute and chronic dislocated intra-articular middle phalanx base fractures.

Hand Surgery ◽  
1997 ◽  
Vol 02 (01) ◽  
pp. 5-16 ◽  
Author(s):  
L. Nagy ◽  
U. Büchler ◽  
D. Birkbeck

Thirty-eight patients with comminuted and impacted fractures at the base of the middle phalanx of the finger involving, on average, 60% of the joint plateau were treated by open reduction, cancellous bone grafting as necessary and minimal internal and/or external fixation. The results were evaluated after a mean follow-up time of 14 months. All patients were satisfied with the outcome and returned to their previous occupations after nine weeks on average. Forty-two percent of patients achieved a good result (no pain, proximal interphalangeal joint flexion/extension better than 90°/–15°, full functional use and good radiographic appearance); 32% had an acceptable result and 13% an unsatisfactory global result. The quality of anatomical reconstruction was the most significant factor determining the final outcome.


2021 ◽  
Vol 53 (05) ◽  
pp. 462-466
Author(s):  
Jun-Ku Lee ◽  
Soonchul Lee ◽  
SeongJu Choi ◽  
Dong Hun Han ◽  
Jongbeom Oh ◽  
...  

Abstract Purpose To report the clinical and radiographic results of arthrodesis of relatively small-sized distal interphalangeal joints (DIPJs) using only K-wire fixation. Patients and methods Between January 2000 and December 2018 28 arthrodesis in 21 patients (9 males and 12 females with an average age of 52.1 years) with relatively small-sized DIPJs were performed using only K-wires. Data on patient’s characteristics, such as age, sex, affected finger, and the number and size of the used k-wires were collected from the medical database. The narrowest diameter of the cortex and medulla of the distal phalanx was measured on preoperative plain radiographs. The time to union and the arthrodesis angle was determined using serial X-ray radiography follow-up. Preoperatively and at the latest follow-up examination, pain using the visual analogue scale (VAS) and the quick DASH score was registered. In addition, complications were investigated. Results Average follow-up period was 11.4 months. The small finger was mostly affected (n = 12; 42.9 %). The narrowest diameters of the distal phalanx cortex and the medulla measured on preoperative X-ray images were 2.8 mm (SD 0.5) and 1.2 mm (SD 0.4), respectively. Seven fusions were done with use of 1 K-wire, 20 with 2 (71.4 %), and 1 with 3 K-wires. The most common K-wire sizes were 1.1-inch (24 K-wires = 48 %), and 0.9 inch (21 K-wires = 42 %) The preoperative VAS score and quick DASH score improved from 6.1 (range: 0–9) and 25.8 (range: 2–38) to 0.4 (range: 0–2) and 3.4 (range: 0–10.2), respectively. 25 (89.3 %) out of 28 fingers achieved bony union in an average of 96.1 days (range: 58–114) with three non-union. Conclusion Arthrodesis of small DIPJs with K-wire fixation has a high success rate. Therefore, we suggest K-wire fixation as an acceptable alternative for patients with a small phalanx which may be at risk of mismatch with bigger implants. However, concerns remain in terms of fusion delay with K-wire only fixation.


2021 ◽  
pp. 175319342110593
Author(s):  
Atsuhiko Murayama ◽  
Kentaro Watanabe ◽  
Hideyuki Ota ◽  
Shigeru Kurimoto ◽  
Hitoshi Hirata

We retrospectively compared the results of volar plating and dynamic external fixation for acute unstable dorsal fracture-dislocations of the proximal interphalangeal joint with a depressed fragment. We treated 31 patients (31 fingers), 12 with volar buttress plating and 19 with dynamic external fixation. Follow-up averaged 35 and 40 months in the two groups, with a minimal 6-month follow-up. Average active flexion of the proximal interphalangeal joint was 95° after plate fixation and 87° after external fixation, with an active extension lag of –6° and –9°, respectively. Active flexion at the distal interphalangeal joint averaged 67° in the plate group and 58° in the external fixation group, with active extension lags of 0° and –5°, respectively. We conclude that both methods can obtain a good range of motion at the proximal interphalangeal joint. A limitation of the extension of the distal interphalangeal joint occurred with dynamic external fixation but not with volar buttress plating. Level of evidence: IV


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Maxim Privalov ◽  
Finn Euler ◽  
Holger Keil ◽  
Benedict Swartman ◽  
Nils Beisemann ◽  
...  

Abstract Background The aim of the study was to evaluate the impact of reduction quality, using intraoperative 3D imaging, on quality of life and functional outcome in the operative treatment of tibial plafond fractures. Methods A group of patients with tibial plafond fractures was re-examined. The operative treatment was performed between September 2001 and October 2011. The follow-up examination was at least 2 years after the final surgical procedure. Final reduction result was assessed intraoperatively using a mobile 3D C-arm. A categorization with regard to descriptive parameters as well as type and size of joint surface irregularities was performed. Follow-up results were evaluated using: Olerud and Molander (O & M) score, Short-Form-36 (SF-36) score, movement deficit, Kellgren and Lawrence grade of osteoarthritis, and pain intensity. Results 34 patients with operatively treated tibial plafond fracture could be re-examined. Reduction quality had the greatest influence on functional result measured by the O & M score (p = 0.001) and the PCS domain of the SF-36 score (p = 0.018). Significant differences with regard to O & M score (p = 0.000), SF-36 score (p = 0.001 to p = 0.02; without MCS domain), movement deficit (p = 0.001), grade of osteoarthritis (p = 0.005) and pain (p = 0.001) could be verified under consideration of the reduction quality. The group with the anatomically more accurate reduction also showed a better result for clinical follow-up and quality of life. Furthermore, it is not the type of joint surface irregularity that is always decisive, but rather the size. Conclusions Despite other relevant factors, it appears that reduction quality –which can be analyzed with intraoperative 3D imaging– plays the most important role in postoperative quality of life and functional outcome. Corrections should therefore be performed on joint surface irregularities with a size above 2 mm.


1992 ◽  
Vol 17 (4) ◽  
pp. 422-428 ◽  
Author(s):  
G. DURHAM-SMITH ◽  
G. M. MCCARTEN

The anatomy and histology of the volar plate at the proximal interphalangeal joint and the mechanism of fracture/subluxation of the base of the middle phalanx in closed proximal interphalangeal joint injuries is reviewed. Our current technique of repair for these injuries and its evolution from Eaton’s original procedure is described. The results of 71 cases of volar plate arthroplasty performed over a five-year period for fracture/subluxations of the proximal interphalangeal joints are presented with follow-up ranging from six months to four years. 62 (87%) patients achieved a stable pain-free joint with a range of motion from 5° to 95° within two months. Complications were uncommon and correctable with an overall eventual patient satisfaction rate of 94%.


Hand Surgery ◽  
2001 ◽  
Vol 06 (01) ◽  
pp. 1-11 ◽  
Author(s):  
Bruce R. Johnstone

A consecutive series of 20 joints in 13 patients underwent arthroplasty with the RMS PIP joint surface replacement implant. Twelve joints were treated for painful osteoarthritis (all females). Two joints were implanted for rheumatoid arthritis, two for post-traumatic pain and stiffness, two for post-traumatic stiffness and one each for post-traumatic pain and pain-free post-traumatic instability. Excellent, often total long-term pain relief was obtained in 18 joints. The other two patients with (compensible work-related) post-traumatic pain and stiffness reported "50–70% pain reduction". No patients lost movement and 14 out of 20 joints were pain-free with a 73.1° average arc of motion. Six joints from the first half of the series had poor motion (average arc of 19.6°), even after open extensor tenolysis or manipulation under anaesthesia. As experience was gained, reliably better results were achieved with a more intensive regimen of hand therapy, particularly within the first post-operative week.


2016 ◽  
Vol 42 (2) ◽  
pp. 188-193 ◽  
Author(s):  
M. Burnier ◽  
T. Awada ◽  
F. Marin Braun ◽  
P. Rostoucher ◽  
M. Ninou ◽  
...  

The primary aim of this study was to assess the clinical and radiological results after hemi-hamate resurfacing arthroplasty in patients with acute or chronic unstable fractures of the base of the middle phalanx and to describe technical features that can facilitate the surgical procedure. Hemi-hamate arthroplasties were done in 19 patients (mean age 39 years) with an isolated fracture at the base of the middle phalanx that involved more than 40% of the articular surface. We assessed ten chronic cases (treated >6 weeks after fracture) and nine acute ones (<6 weeks) at a mean of 24 months. Pain scores, QuickDASH scores, grip strengths, range of motion and radiological findings were recorded at follow-up. At follow-up, the mean active flexion at the proximal interphalangeal joint was to 83° with a mean fixed flexion of 17° (active range of motion 66°). The mean active distal interphalangeal motion was 41°. The mean visual analogue scale score was 1.1. The mean QuickDASH score was 11. The mean pinch strength was 82% of the opposite side. Radiographs revealed one partial graft lysis. Level of evidence: IV


2009 ◽  
Vol 35 (3) ◽  
pp. 188-191 ◽  
Author(s):  
A. M. Afifi ◽  
A. Richards ◽  
A. Medoro ◽  
D. Mercer ◽  
M. Moneim

Current approaches to the proximal interphalangeal (PIP) joint have potential complications and limitations. We present a dorsal approach that involves splitting the extensor tendon in the midline, detaching the insertion of the central slip and repairing the extensor tendon without reinserting the tendon into the base of the middle phalanx. A retrospective review of 16 digits that had the approach for a PIP joint arthroplasty with a mean follow up of 23 months found a postoperative PIP active ROM of 61° (range 25–90°). Fourteen digits had no extensor lag, while two digits had an extensor lag of 20° and 25°. This modified approach is fast and simple and does not cause an extensor lag.


2021 ◽  
Vol 26 (3) ◽  
pp. 171-173
Author(s):  
Kyung Jin Lee ◽  
Jung Hyun Park ◽  
Sung Hoon Koh ◽  
Dong Chul Lee ◽  
Si Young Roh ◽  
...  

Kirschner wire (K-wire) has been widely used for treatment of fracture for its cost-effectiveness and reliability. This case presents the K-wire breakage in distal interphalangeal joint (DIPJ) fixation. A 55-year-old male patient was injured by a knife and showed rupture of extensor tendon at 1/2 of middle phalanx. A 0.9-mm K-wire was implemented for DIPJ extension, and tenorrhaphy was done. After 6 weeks, we detected breakage of K-wire in the follow-up X-ray. The broken K-wire in the distal phalanx was removed. We removed the remaining K-wire through an incision on volar side of middle phalanx under C-arm after 2 weeks for the patient’s personal reasons. Breakage during postoperative K-wire maintenance is exceedingly rare. This patient is presumed to have ruptured because he continued using his finger. Therefore, while K-wire is present, continued use of finger without protection may cause breakage, so protective measures such as splint are required.


2021 ◽  
Author(s):  
B Barone Gibbs ◽  
C E Kline ◽  
K A Huber ◽  
J L Paley ◽  
S Perera

Abstract Background Emerging cross-sectional reports find that the COVID-19 pandemic and related social restrictions negatively affect lifestyle behaviours and mental health in general populations. Aims To study the longitudinal impact of COVID-19 on work practices, lifestyle and well-being among desk workers during shelter-at-home restrictions. Methods We added follow-up after completion of a clinical trial among desk workers to longitudinally measure sedentary behaviour, physical activity, sleep, diet, mood, quality of life and work-related health using validated questionnaires and surveys. We compared outcomes assessed before and during COVID-19 shelter-at-home restrictions. We assessed whether changes in outcomes differed by remote working status (always, changed to or never remote) using analysis of covariance (ANCOVA). Results Participants (N = 112; 69% female; mean (SD) age = 45.4 (12.3) years; follow-up = 13.5 (6.8) months) had substantial changes to work practices, including 72% changing to remote work. Deleterious changes from before to during shelter-at-home included: 1.3 (3.5)-h increase in non-workday sedentary behaviour; 0.7 (2.8)-point worsening of sleep quality; 8.5 (21.2)-point increase in mood disturbance; reductions in five of eight quality of life subscales; 0.5 (1.1)-point decrease in work-related health (P &lt; 0.05). Other outcomes, including diet, physical activity and workday sedentary behaviour, remained stable (P ≥ 0.05). Workers who were remote before and during the pandemic had greater increases in non-workday sedentary behaviour and stress, with greater declines in physical functioning. Wake time was delayed overall by 41 (61) min, and more so in workers who changed to remote. Conclusions Employers should consider supporting healthy lifestyle and well-being among desk workers during pandemic-related social restrictions, regardless of remote working status.


Sign in / Sign up

Export Citation Format

Share Document