Design and Evaluation of Two Dimensional Metrological Atomic Force Microscope using a Planar Nanoscanner

2006 ◽  
Vol 45 (3B) ◽  
pp. 2124-2127 ◽  
Author(s):  
Dong-Yeon Lee ◽  
Dong-Min Kim ◽  
Dae-Gab Gweon
2017 ◽  
Vol 5 (4) ◽  
Author(s):  
E. B. Brousseau ◽  
S. Thiery ◽  
B. Arnal ◽  
E. Nyiri ◽  
O. Gibaru ◽  
...  

This paper reports a feasibility study that demonstrates the implementation of a computer-aided design and manufacturing (CAD/CAM) approach for producing two-dimensional (2D) patterns on the nanoscale using the atomic force microscope (AFM) tip-based nanomachining process. To achieve this, simple software tools and neutral file formats were used. A G-code postprocessor was also developed to ensure that the controller of the AFM equipment utilized could interpret the G-code representation of tip path trajectories generated using the computer-aided manufacturing (CAM) software. In addition, the error between a machined pattern and its theoretical geometry was also evaluated. The analyzed pattern covered an area of 20 μm × 20 μm. The average machined error in this case was estimated to be 66 nm. This value corresponds to 15% of the average width of machined grooves. Such machining errors are most likely due to the flexible nature of AFM probe cantilevers. Overall, it is anticipated that such a CAD/CAM approach could contribute to the development of a more flexible and portable solution for a range of tip-based nanofabrication tasks, which would not be restricted to particular customised software or AFM instruments. In the case of nanomachining operations, however, further work is required first to generate trajectories, which can compensate for the observed machining errors.


Author(s):  
C. Miyasaka ◽  
B. R. Tittmann ◽  
T. Adachi ◽  
A. Yamaji

When the Ultrasonic-Atomic Force Microscope (U-AFM) is used to form an image of a surface of a specimen having discontinuities, contrast of the specimen in the image is usually stronger than that of an image formed by a conventional Atomic Force Microscope (AFM). In this article, the mechanism of the contrast of the image obtained by the U-AFM was explained by theoretical analysis. A ceramic and metal jointed bar (Steel/Cu/Si3N4) was selected as a specimen for this study. The specimen was located on the surface of a disc transducer generating ultrasonic waves up to 500 KHz, and was vibrated, wherein its first resonant frequency was 133.43 kHz. Both stress and displacement of the specimen were analyzed by classical beam theory and the two-dimensional elasto-dynamic theory. Experimental U-AFM imaging analyses were also carried out to compare the results.


Author(s):  
Deman Tang ◽  
Earl H. Dowell

Dynamic analysis and numerical simulation of a protein-ligand chain structure connected to a moving atomic force microscope (AFM) has been conducted. The elements of the chain are free to extend and rotate relative to each other in a two-dimensional plane. Sinusoidal base excitation of the cantilevered beam of the AFM is considered in some detail. Reduced order (dynamic) models are constructed using global modes for both linear and nonlinear dynamic systems with and without the “nearest neighbor assumption”. The agreement between the original and reduced order models (ROM) is very good even when only one global mode is included in the ROM for either the linear case or for the nonlinear case, provided the excitation frequency is lower than the fundamental natural frequency of the linear system. For higher excitation frequencies, more global modes are required. The computational advantage of the reduced order model is clear from the results presented.


2005 ◽  
Author(s):  
Jong-Ahn Kim ◽  
Jae Wan Kim ◽  
Byong Chon Park ◽  
Tae Bong Eom ◽  
Chu-Shik Kang

2007 ◽  
Vol 46 (9B) ◽  
pp. 6458-6462 ◽  
Author(s):  
Terunobu Akiyama ◽  
Laure Aeschimann ◽  
Laura Chantada ◽  
Nico. F. de Rooij ◽  
Harry Heinzelmann ◽  
...  

2019 ◽  
Vol 89 (11) ◽  
pp. 1807
Author(s):  
А.Г. Темирязев ◽  
М.П. Темирязева ◽  
А.В. Здоровейщев ◽  
О.В. Вихрова ◽  
Ю.В. Никулин ◽  
...  

The paper presents examples of the use of pulse force nanolithography, performed with a probe of an atomic force microscope, to form magnetic nanowires, nanocontacts, one- and two-dimensional arrays with characteristic dimensions of about 50-100 nm.


Sign in / Sign up

Export Citation Format

Share Document