Weak Irradiation Effect on the Inversion-Recovery Process of a13C-1H Spin System. I. Selective Inversion

1993 ◽  
Vol 62 (11) ◽  
pp. 4093-4103 ◽  
Author(s):  
Mitsumasa Ishiwata
2012 ◽  
Vol 14 (S1) ◽  
Author(s):  
Lukas Havla ◽  
Tamer A Basha ◽  
Hussein Rayatzadeh ◽  
Jaime L Shaw ◽  
Warren J Manning ◽  
...  

2020 ◽  
Vol 68 ◽  
pp. 66-74 ◽  
Author(s):  
Matthew J. Cronin ◽  
Junzhong Xu ◽  
Francesca Bagnato ◽  
Daniel F. Gochberg ◽  
John C. Gore ◽  
...  

1992 ◽  
Vol 23 (1) ◽  
pp. 109-121 ◽  
Author(s):  
Samuel J. Wang ◽  
Dwight G. Nishimura ◽  
Albert Macovski

1991 ◽  
Vol 17 (1) ◽  
pp. 244-251 ◽  
Author(s):  
Samuel J. Wang ◽  
Dwight G. Nishimura ◽  
Albert Macovski

2009 ◽  
Vol 62 (2) ◽  
pp. 314-324 ◽  
Author(s):  
Evert-jan Vonken ◽  
Grigorios Korosoglou ◽  
Jing Yu ◽  
Michael Schär ◽  
Ralph Weissleder ◽  
...  

2015 ◽  
Vol 4 (5) ◽  
pp. 205846011558411 ◽  
Author(s):  
Tsuyoshi Ohno ◽  
Hiroyoshi Isoda ◽  
Akihiro Furuta ◽  
Kaori Togashi

Background A 3 Tesla (3 T) magnetic resonance (MR) scanner is a promising tool for upper abdominal MR angiography. However, there is no report focused on the image quality of non-contrast-enhanced MR portography and hepatic venography at 3 T. Purpose To compare and evaluate images of non-contrast-enhanced MR portography and hepatic venography with time-spatial labeling inversion pulses (Time-SLIP) at 1.5 Tesla (1.5 T) and 3 T. Material and Methods Twenty-five healthy volunteers were examined using respiratory-triggered three-dimensional balanced steady-state free-precession (bSSFP) with Time-SLIP. For portography, we used one tagging pulse (selective inversion recovery) and one non-selective inversion recovery pulse; for venography, two tagging pulses were used. The relative signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were quantified, and the quality of visualization was evaluated. Results The CNRs of the main portal vein, right portal vein, and left portal vein at 3 T were better than at 1.5 T. The image quality scores for the portal branches of segment 4, 5, and 8 were significantly higher at 3 T than at 1.5 T. The CNR of the right hepatic vein (RHV) at 3 T was significantly lower than at 1.5 T. The image quality scores of RHV and the middle hepatic vein were higher at 1.5 T than at 3 T. For RHV visualization, the difference was statistically significant. Conclusion Non-contrast-enhanced MR portography with Time-SLIP at 3 T significantly improved visualization of the peripheral branch in healthy volunteers compared with1.5 T. Non-contrast-enhanced MR hepatic venography at 1.5 T was better than at 3 T.


Sign in / Sign up

Export Citation Format

Share Document