Effect of high-frequency oscillation on lung lymph flow

1983 ◽  
Vol 55 (5) ◽  
pp. 1373-1378 ◽  
Author(s):  
A. L. Jefferies ◽  
P. Hamilton ◽  
H. M. O'Brodovich

We investigated the effect of high-frequency oscillation (HFO) on lung lymphatic function under normal conditions and when lung lymph flow was increased by air microembolization. In six experiments, sheep and goats with chronic lung lymph fistulas and vascular catheters were anesthetized, paralyzed, intubated, and ventilated according to the following protocol: 1) intermittent positive-pressure ventilation (IPPV) for 1 h, 2) HFO with a frequency of 15 Hz and an estimated tidal volume of 1-2 ml/kg for 1-2 h, and 3) IPPV for 0.5 h. Ventilator settings were adjusted to maintain arterial Po2 above 100 Torr and a normal arterial Pco2. Vascular, esophageal, and mean airway pressures were monitored continuously. Lymph flow and cardiac output were recorded every 15 min. With this protocol, there were no changes in pulmonary vascular or esophageal pressures, and lymph flow remained stable throughout the experiment. In an additional five experiments, air microemboli were infused for approximately 30 min during HFO. Left atrial pressure was unchanged and lymph flow tripled. This response was qualitatively and quantitatively similar to that previously reported for unanesthetized spontaneously breathing sheep. We conclude that HFO does not impair lymphatic function under resting conditions and that lymphatics retain their ability to increase water and protein clearance during HFO.

1992 ◽  
Vol 2 (3) ◽  
pp. 277-280 ◽  
Author(s):  
Daniel J. Penny ◽  
Zamir Hayek ◽  
Peter Rawle ◽  
Michael L. Rigby ◽  
Andrew N. Redington

AbstractIn this prospective study, pulmonary blood flow was measured using transesophageal Doppler echocardiography to assess whether ventilation by means of external high frequency oscillation around a negative pressure baseline can increase pulmonary blood flow, compared to intermittent positive pressure ventilation, in five patients after the Fontan operation. Pulmonary blood flow was measured when patients were ventilated by means of intermittent positive pressure ventilation and again during equivalent negative pressure ventilation using the external oscillatory technique. When compared to that with intermittent positive pressure ventilation, ventilation using external high frequency oscillation increased pulmonary blood flow by 116 ±61.5% (p=0.013). These results show that ventilation using an external oscillatory device with a mean negative chamber pressure may provide hemodynamic advantages in patients requiring assisted ventilation after the Fontan operation.


1978 ◽  
Vol 42 (4) ◽  
pp. 550-557 ◽  
Author(s):  
W C Woolverton ◽  
K L Brigham ◽  
N C Staub

1982 ◽  
Vol 52 (3) ◽  
pp. 543-548 ◽  
Author(s):  
W. K. Thompson ◽  
B. E. Marchak ◽  
A. B. Froese ◽  
A. C. Bryan

Hemorrhagic pulmonary edema was induced by intra-atrial infusion of 0.04--0.1 ml/kg of oleic acid into six anesthetized dogs. Gas exchange and cardiac outputs were then compared at identical mean airway pressures during randomized ventilation with either a volume-cycled ventilator with positive end-expiratory pressure (conventional positive-pressure ventilation, tidal volume 16--21 ml/kg, frequency 15--20 cycles/min) or a variable volume piston pump operating at 15 Hz (high-frequency oscillation). The fractional inspired oxygen concentration was maintained at 0.5 throughout. During 17 data sets matched for intratracheal mean airway pressures over a range of 7.5--27 cmH2O, measurements of systemic arterial pressure, arterial blood gas tensions, thermodilution cardiac outputs, and pulmonary arterial and capillary wedge pressures were identical (P less than 0.05) during ventilation with conventional positive-pressure ventilation and high-frequency oscillation. With both forms of ventilation, arterial oxygen tension progressively improved as mean airway pressure increased. In a shunt model of acute lung injury we were unable to show significant differences in oxygenation or cardiac output when high-frequency oscillation was compared with conventional positive-pressure ventilation with positive end-expiratory pressure at equivalent mean airway pressures.


1986 ◽  
Vol 60 (1) ◽  
pp. 38-44 ◽  
Author(s):  
H. O'Brodovich ◽  
G. Coates

Experiments were performed to determine whether different methods of increasing cardiac output would have similar effects on lung lymph flow, and to assess the contribution of the microvasculature (fluid-exchanging vessels) to the total calculated pulmonary vascular resistance. Yearling unanesthetized sheep with chronic vascular catheters and lung lymph fistulas underwent intravenous infusions of isoproterenol at 0.2 micrograms X kg-1. min-1 (n = 8) or were exercised on a treadmill (n = 16). Both isoproterenol and exercise increased cardiac output, lowered calculated total pulmonary and systemic vascular resistances, and had no effect on the calculated pulmonary microvascular pressure. Isoproterenol infusions did not affect lung lymph flow, whereas exercise increased lung lymph flow in proportion to the increase in cardiac output. We conclude that 1) the sheep has a different pulmonary hemodynamic response to exercise than dogs and man, 2) the microvasculature is recruited during exercise-induced but not isoproterenol-induced increases in cardiac output, and 3) the microvasculature represents only a small proportion of the total calculated pulmonary vascular resistance.


PEDIATRICS ◽  
2001 ◽  
Vol 108 (1) ◽  
pp. 212-214
Author(s):  
J. P. Shenai; ◽  
P. Rimensberger; ◽  
U. Thome ◽  
F. Pohlandt; ◽  
P. Rimensberger

IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Mohammad Habibullah ◽  
Nadarajah Mithulananthan ◽  
Krischonme Bhumkittipich ◽  
Mohammad Amin

Sign in / Sign up

Export Citation Format

Share Document