Plethysmographic estimation of thoracic gas volume in apneic mice

2006 ◽  
Vol 101 (2) ◽  
pp. 454-459 ◽  
Author(s):  
Tibor Z. Jánosi ◽  
Ágnes Adamicza ◽  
Graeme R. Zosky ◽  
Tibor Asztalos ◽  
Peter D. Sly ◽  
...  

Electrical stimulation of intercostal muscles was employed to measure thoracic gas volume (TGV) during airway occlusion in the absence of respiratory effort at different levels of lung inflation. In 15 tracheostomized and mechanically ventilated CBA/Ca mice, the value of TGV obtained from the spontaneous breathing effort available in the early phase of the experiments (TGVsp) was compared with those resulting from muscle stimulation (TGVst) at transrespiratory pressures of 0, 10, and 20 cmH2O. A very strong correlation ( r2 = 0.97) was found, although with a systematically (∼16%) higher estimation of TGVst relative to TGVsp, attributable to the different durations of the stimulated (∼50 ms) and spontaneous (∼200 ms) contractions. Measurements of TGVst before and after injections of 0.2, 0.4, and 0.6 ml of nitrogen into the lungs in six mice resulted in good agreement between the change in TGVst and the injected volume ( r2 = 0.98). In four mice, TGVsp and TGVst were compared at end expiration with air or a helium-oxygen mixture to confirm the validity of isothermal compression in the alveolar gas. The TGVst values measured at zero transrespiratory pressure in all CBA/Ca mice [0.29 ± 0.05 (SD) ml] and in C57BL/6 ( N = 6; 0.34 ± 0.08 ml) and BALB/c ( N = 6; 0.28 ± 0.06 ml) mice were in agreement with functional residual capacity values from previous studies in which different techniques were used. This method is particularly useful when TGV is to be determined in the absence of breathing activity, when it must be known at any level of lung inflation or under non-steady-state conditions, such as during pharmaceutical interventions.

1985 ◽  
Vol 58 (6) ◽  
pp. 1783-1787 ◽  
Author(s):  
L. J. Folinsbee ◽  
J. F. Bedi ◽  
S. M. Horvath

We exposed 22 healthy adult nonsmoking male subjects for 2 h to filtered air, 1.0 ppm sulfur dioxide (SO2), 0.3 ppm ozone (O3), or the combination of 1.0 ppm SO2 + 0.3 ppm O3. We hypothesized that exposure to near-threshold concentrations of these pollutants would allow us to observe any interaction between the two pollutants that might have been masked by the more obvious response to the higher concentrations of O3 used in previous studies. Each subject alternated 30-min treadmill exercise with 10-min rest periods for the 2 h. The average exercise ventilation measured during the last 5 min of exercise was 38 1/min (BTPS). Forced expiratory maneuvers were performed before exposure and 5 min after each of the three exercise periods. Maximum voluntary ventilation, He dilution functional residual capacity, thoracic gas volume, and airway resistance were measured before and after the exposure. After O3 exposure alone, forced expiratory measurements (FVC, FEV1.0, and FEF25–75%) were significantly decreased. The combined exposure to SO2 + O3 produced similar but smaller decreases in these measures. There were small but significant differences between the O3 and the O3 + SO2 exposure for FVC, FEV1.0, FEV2.0, FEV3.0, and FEF25–75% at the end of the 2-h exposure. We conclude that, with these pollutant concentrations, there is no additive or synergistic effect of the two pollutants on pulmonary function.


1982 ◽  
Vol 52 (4) ◽  
pp. 995-999 ◽  
Author(s):  
C. S. Beardsmore ◽  
J. Stocks ◽  
M. Silverman

Thoracic gas volume (TGV) was measured with a whole-body plethysmograph in 20 infants at functional residual capacity (FRC) and at a series of higher lung volumes achieved by artificial inflation of the lungs with known volumes of air after airway occlusion. There was a discrepancy between the corrected values of TGV measured at high and low lung volumes in nine infants; in six cases TGV measured at high lung volumes exceeded that measured at FRC, and in three cases it was reduced when compared with the measurement made at FRC. These changes were not related to age, size, or clinical status and could be explained by airway closure at FRC, combined with an uneven distribution of pleural pressure.


2008 ◽  
Vol 105 (2) ◽  
pp. 685-692 ◽  
Author(s):  
Graeme R. Zosky ◽  
Tibor Z. Janosi ◽  
Ágnes Adamicza ◽  
Elizabeth M. Bozanich ◽  
Vincenzo Cannizzaro ◽  
...  

The double sigmoidal nature of the mouse pressure-volume (PV) curve is well recognized but largely ignored. This study systematically examined the effect of inflating the mouse lung to 40 cm H2O transrespiratory pressure (Prs) in vivo. Adult BALB/c mice were anesthetized, tracheostomized, and mechanically ventilated. Thoracic gas volume was calculated using plethysmography and electrical stimulation of the intercostal muscles. Lung mechanics were tracked during inflation-deflation maneuvers using a modification of the forced oscillation technique. Inflation beyond 20 cm H2O caused a shift in subsequent PV curves with an increase in slope of the inflation limb and an increase in lung volume at 20 cm H2O. There was an overall decrease in tissue elastance and a fundamental change in its volume dependence. This apparent “softening” of the lung could be recovered by partial degassing of the lung or applying a negative transrespiratory pressure such that lung volume decreased below functional residual capacity. Allowing the lung to spontaneously recover revealed that the lung required ∼1 h of mechanical ventilation to return to the original state. We propose a number of possible mechanisms for these observations and suggest that they are most likely explained by the unfolding of alveolar septa and the subsequent redistribution of the fluid lining the alveoli at high transrespiratory pressure.


1961 ◽  
Vol 16 (4) ◽  
pp. 717-719 ◽  
Author(s):  
Jay A. Nadel ◽  
Donald F. Tierney

We measured airway resistance and thoracic gas volume by the body plethysmograph technique, and transpulmonary pressure in seven healthy, adult subjects, before and after induction of bronchoconstriction. A deep inspiration never altered airway resistance, measured at functional residual capacity in the control state, but always reduced it for 1—2 min when bronchoconstriction was present. Discrepancies in data published on airway resistance may be due to use of methods which require a deep inspiration, or to occurrence of a spontaneous deep inspiration shortly before the test. Submitted on January 13, 1961


2008 ◽  
Vol 105 (6) ◽  
pp. 1864-1872 ◽  
Author(s):  
Z. Hantos ◽  
Á. Adamicza ◽  
T. Z. Jánosi ◽  
M. V. Szabari ◽  
J. Tolnai ◽  
...  

Absolute lung volumes such as functional residual capacity, residual volume (RV), and total lung capacity (TLC) are used to characterize emphysema in patients, whereas in animal models of emphysema, the mechanical parameters are invariably obtained as a function of transrespiratory pressure (Prs). The aim of the present study was to establish a link between the mechanical parameters including tissue elastance (H) and airway resistance (Raw), and thoracic gas volume (TGV) in addition to Prs in a mouse model of emphysema. Using low-frequency forced oscillations during slow deep inflation, we tracked H and Raw as functions of TGV and Prs in normal mice and mice treated with porcine pancreatic elastase. The presence of emphysema was confirmed by morphometric analysis of histological slices. The treatment resulted in an increase in TGV by 51 and 44% and a decrease in H by 57 and 27%, respectively, at 0 and 20 cmH2O of Prs. The Raw did not differ between the groups at any value of Prs, but it was significantly higher in the treated mice at comparable TGV values. In further groups of mice, tracheal sounds were recorded during inflations from RV to TLC. All lung volumes but RV were significantly elevated in the treated mice, whereas the numbers and size distributions of inspiratory crackles were not different, suggesting that the airways were not affected by the elastase treatment. These findings emphasize the importance of absolute lung volumes and indicate that tissue destruction was not associated with airway dysfunction in this mouse model of emphysema.


1982 ◽  
Vol 53 (5) ◽  
pp. 1220-1227 ◽  
Author(s):  
L. M. Taussig ◽  
L. I. Landau ◽  
S. Godfrey ◽  
I. Arad

Maximal flows at functional residual capacity (VmaxFRC) from partial expiratory flow-volume (PEFV) curves (achieved with rapid compression of the chest) were obtained on 11 healthy newborn babies. Mean VmaxFRC, size corrected by dividing absolute values by measured thoracic gas volume, was 1.90 TGV's/s. Specific upstream conductances were high, and the cross-sectional area of the flow-limiting segment was estimated to be approximately 0.30 cm2 in the three infants on whom recoil pressures at FRC were also measured. The cross-sectional area of the major bronchi in the neonate is approximately 0.26–0.30 cm2. PEFV curves were convex to the volume axis. Many of the neonates increased their flows while breathing a helium-oxygen gas mixture. These results suggest 1) size-corrected flows are higher in the neonate than in older children or adults; 2) the site of the flow-limiting segment at FRC during maximal expiratory maneuvers is in large proximal airways, similar to the adult; and 3) the relationship of airway size to parenchymal size may be similar in neonates and adults or, in fact, airways may be larger, relative to parenchyma, in neonates. These physiological data do not support the hypothesis, based on pathological studies, that peripheral airways are disproportionately smaller (when compared with central airways) in infants than in adults.


1987 ◽  
Vol 63 (1) ◽  
pp. 277-284 ◽  
Author(s):  
Y. Kikuchi ◽  
W. Hida ◽  
C. Shindoh ◽  
T. Chonan ◽  
H. Miki ◽  
...  

We examined the effect of digitalis on diaphragmatic contractility and fatigability in 19 anesthetized mechanically ventilated dogs. The diaphragmatic force was assessed from transdiaphragmatic pressure (Pdi) developed at functional residual capacity against an occluded airway during cervical phrenic nerve stimulation. In a first group of five dogs, Pdi-stimulus frequency relationships were compared before and after administration of ouabain in doses of 0.01, 0.02, and 0.04 mg/kg. In a second group, diaphragmatic fatigue was produced by bilateral phrenic nerve stimulation at 30 Hz. Ten seconds of stimulation and 15 s of mechanical ventilation were repeated for 30 min. The rates of decrease in Pdi were compared between two groups, one of 0.05 mg/kg deslanoside-treated dogs (n = 7) and one of nontreated dogs (n = 7). After ouabain administration Pdi was significantly greater at each frequency in a dose-dependent manner. On the other hand, the rate of decrease in Pdi in the deslanoside group was significantly smaller than that in the nontreated group, whereas deslanoside did not greatly change the Pdi-frequency curves in fresh diaphragm. We conclude that ouabain improves contractility of the fresh diaphragm and that deslanoside has a protective effect against fatigability.


1998 ◽  
Vol 84 (2) ◽  
pp. 553-561 ◽  
Author(s):  
R. Peslin ◽  
C. Duvivier

Peslin, R., and C. Duvivier. Partitioning of airway and respiratory tissue mechanical impedances by body plethysmography. J. Appl. Physiol. 84(2): 553–561, 1998.—We have tested the feasibility of separating the airway (Zaw) and tissue (Zti) components of total respiratory input impedance (Zrs,in) in healthy subjects by measuring alveolar gas compression by body plethysmography (Vpl) during pressure oscillations at the airway opening. The forced oscillation setup was placed inside a body plethysmograph, and the subjects rebreathedbtps gas. Zrs,in and the relationship between Vpl and airway flow (Hpl) were measured from 4 to 29 Hz. Zaw and Zti were computed from Zrs,in and Hpl by using the monoalveolar T-network model and alveolar gas compliance derived from thoracic gas volume. The data were in good agreement with previous observations: airway and tissue resistance exhibited some positive and negative frequency dependences, respectively; airway reactance was consistent with an inertance of 0.015 ± 0.003 hPa ⋅ s2 ⋅ l−1and tissue reactance with an elastance of 36 ± 8 hPa/l. The changes seen with varying lung volume, during elastic loading of the chest and during bronchoconstriction, were mostly in agreement with the expected effects. The data, as well as computer simulation, suggest that the partitioning is unaffected by mechanical inhomogeneity and only moderately affected by airway wall shunting.


1994 ◽  
Vol 77 (3) ◽  
pp. 1562-1564 ◽  
Author(s):  
Y. Sivan ◽  
J. Hammer ◽  
C. J. Newth

Studies on human infants suggested that thoracic gas volume (TGV) measured at end exhalation may not depict the true TGV and may differ from TGV measured from a series of higher lung volumes and corrected for the volume added. This was explained by gas trapping. If true, we should expect the discrepancy to be more pronounced when functional residual capacity (FRC) and higher lung volumes are measured by gas dilution techniques. We studied lung volumes above FRC by the nitrogen washout technique in 12 spontaneously breathing rhesus monkeys (5.0–11.3 kg wt; 42 compared measurements). Lung volumes directly measured were compared with preset lung volumes achieved by artificial inflation of the lungs above FRC with known volumes of air (100–260 ml). Measured lung volume strongly correlated with and was not significantly different from present lung volume (P = 0.05; r = 0.996). The difference between measured and preset lung volume was 0–5% in 41 of 42 cases [1 +/- 0.4% (SE)]. The direction of the difference was unpredictable; in 22 of 42 cases the measured volume was larger than the preset volume, but in 17 of 42 cases it was smaller. The difference was not affected by the volume of gas artificially inflated into the lungs. We conclude that, overall, lung volumes above FRC can be reliably measured by the nitrogen washout technique and that FRC measurements by this method reasonably reflect true FRC.


Sign in / Sign up

Export Citation Format

Share Document