scholarly journals A Validated RP-HPLC Method for the Determination of Recombinant Human Insulin in Bulk and Pharmaceutical Dosage Form

2010 ◽  
Vol 7 (s1) ◽  
pp. S449-S457 ◽  
Author(s):  
B. A. Moussa ◽  
F. Farouk ◽  
H. M. E. Azzazy

A modified RP-HPLC method was developed for the quantitative determination of recombinant human insulin in bulk and pharmaceutical dosage form with reduced retention time. Study of the effects of the column temperature, pH of the mobile phase and presence of vial additives (phenol andm-cresol), or impurities (A-21 Disamido) on the accuracy of the assay were assessed. Separation was achieved using a Hypersil BDS C-18 column and the mobile phase was composed of solution A (aqueous solution of 28.3 anhydrous Na2SO4g/L, pH 2.3) and solution B (28.5 g anhydrous Na2SO4g/L in 50:50 mixture of water and acetonitrile, pH 2.3) in a ratio 48:52 (v/v) at 45–50°C. The column temperature was 40°C, the flow rate was 1 mL/min and detection was performed at 216 nm. The procedures were validated according to international conference on harmonization (ICH) guidelines. Recovery study was done applying standard addition technique for further validation of the procedure. The retention time of recombinant human insulin was 19.7 min as compared to 29 min obtained by the reference method. Analytical conditions fluctuations or presence of vial additives or impurities did not show any significant effect on the accuracy of the method. The prepared standard insulin solution in 0.01 N HCl was found to be stable for 5 days. Statistical comparison showed no significant difference between the described method and reference method regarding the accuracy and precision. The modified method can be applied for routine quality control applications for determination of recombinant human insulin.

INDIAN DRUGS ◽  
2014 ◽  
Vol 51 (12) ◽  
pp. 32-36
Author(s):  
T. Vishalakhi ◽  
◽  
S. K Kumar ◽  
K Sujana ◽  
P Rani

A simple validated RP HPLC method for the estimation of rizatriptan benzoate in pharmaceutical dosage form and bulk was developed for routine analysis. This method was developed by selecting Agilent TC C18 (250 x 4.6 mm, 5 μ) column as stationary phase and acrylonibrile:water (45:55), pH adjusted to 3, as mobile phase. Flow rate of mobile phase was maintained at 4: 1 mL/min at ambient temperature throughout the experiment. Quantification was achieved with ultraviolet (DAD) detection at 220 nm. The retention time obtained for rizatriptan was 2.8 min. The detector response was linear in the concentration range of 2-25μg/mL. This method was validated and shown to be specific, sensitive, precise, linear, accurate, rugged and robust. Hence, this method can be applied for routine quality control of rizatriptan benzoate in dosage forms as well as in bulk drug.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (01) ◽  
pp. 35-40
Author(s):  
Rajesh Sharma ◽  
◽  
Mukesh C. Sharma ◽  
Gaurav Vijaywargiya

Chromatographic separation of paracetamol, aceclofenac and tramadol hydrochloride was performed on a Chromatopak C-18 column (25 cm x 4.6mm i.d. x 5µm) as stationary phase with a mobile phase composed of phosphate buffer pH 7.0: acetonitrile (65:35 V/V), pH 7.0 (adjusted with triethylamine) at flow rate of 1mL/min. Detection was carried out at 265 nm. The retention times of paracetamol, aceclofenac and Tramadol hydrochloride were found to be 2.7, 4.5 and 6.0 min, respectively. The proposed method was validated for linearity, accuracy, precision, LOD and LOQ. The method was found to be accurate, precise, specific, robust, and linear for the determination of paracetamol, aceclofenac and tramadol hydrochloride in pharmaceutical dosage form.


2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
M. V. Basaveswara Rao ◽  
A. V. D Nagendrakumar ◽  
Sushanta Maiti ◽  
N. Chandrasekhar

A simple, selective, linear, precise, and accurate RP-HPLC method was developed and validated for rapid assay of Pizotifen in pharmaceutical dosage form. Isocratic elution at a flow rate of 1.0 mL/min was employed on Chromosil C18 (250 mm × 4.6 mm, 5 μm) column at ambient temperature. The mobile phase consists of methanol : acetonitrile in the ratio of 10 : 90 v/v. The UV detection wavelength was 230 nm, and 20 μL sample was injected. The retention time for Pizotifen was 2.019 min. The percent RSD for accuracy of the method was found to be 0.2603%. The method was validated as per the ICH guidelines. The method can be successfully applied for routine analysis of Pizotifen in the rapid and reliable determination of Pizotifen in pharmaceutical dosage form.


Author(s):  
Sushil D. Patil ◽  
Pravin B. Shelke ◽  
Priti Aher ◽  
Maswood Ahmed Hafizur Rahman

A simple, rapid, economic, sensitive and precise HPLC method has been developed for the simultaneous determination of Sulphadoxine and Pyrimethamine in pharmaceutical dosage form by taking Tolterodine as an internal standard. The method was carried out using Phenomenex C18 (4.6ID × 250mm; 5µm) column and mobile phase comprised of methanol and Phosphate Buffer in proportion of ratio 60:40 v/v. The flow rate was 1.0mL/min and detection was carried out at 276nm. The retention time of Sulphadoxine, Pyrimethamine and Tolterodine were found to be 2.967, 4.058 and 6.908 respectively. Linearity of Sulphadoxine and Pyrimethamine in the range of 2 to 12μg/mL and 4 to 24μg/mL respectively. The % recoveries of Sulphadoxine and Pyrimethamine were found to be in between 99.93% to 99. 96 % respectively. The proposed method is suitable for the routine quality control analysis for simultaneous determination of Sulphadoxine and Pyrimethamine was in bulk and pharmaceutical dosage form.


2013 ◽  
Vol 19 (3) ◽  
pp. 333-337 ◽  
Author(s):  
A.C. Arvadiya ◽  
P.P. Dahivelker

A simple, precise, accurate, sensitive and repeatable RP-UPLC method was developed for quantitative determination of atropine sulphate in pharmaceutical dosage form. The method was developed by using C18 column Hiber HR Purospher Star (100mm?2.1mm id, 2?m particle size) as stationary phase with Phosphate Buffer: Acetonitrile (87:13, %v/v) as a mobile phase, pH was adjusted to 3.5 by ortho-phosphoric acid at a flow rate of 0.5 mL/min and column temperature maintained at 30?C. Quantification of eluted compound was achieved with PDA detector at 210 nm. Atropine sulphate followed linearity in concentration range of 2.5-17.5 ?g/mL with r2=0.9998 (n=6). Limit of detection (LOD) and limit of quantification (LOQ) values were 0.0033 and 0.0102 ?g/mL for atropine sulphate. The validation study is carried out as per International Conference on Harmonization (ICH) guidelines. This method was successfully applied for estimation of atropine sulphate in pharmaceutical formulation.


Author(s):  
Sonalika Patro ◽  
S. Harshith Kumar ◽  
M. Barath kumar ◽  
E. Masthaniah ◽  
K. Sairam ◽  
...  

A Simple, accurate and precise method was developed and validated for the determination of flucloxacillin sodium in its tablet dosage form. The separation was eluted on xterra c18 column (4.6x150mm, 5micron) using a mixture of octane buffer and methanol as mobile phase in a ratio of (30:70) which was pumped through column at a flow rate of  1ml/min. Optimised wavelength for flucloxacillin was 237nm, the retention time was 2.305minutes and the percentage purity was found to be 98.14%. System suitability parameters such as theoretical plate and tailing factor for flucloxacillin sodium was found to be 2991.64 and 1.90 respectively, the proposed method was validated as per ICH guidelines (ICH, Q2 AND (R1)) the method was found to be linear at the concentration range of 20-100µg/ml and the correlation coefficient (r2) value was found to be 0.9994 percentage RSD for precision was 0.9% and percentage RSD for ruggedness was 0.5%. The precision study was precise, robust and repeatable. The LOD and LOQ values are 2.98 and 9.98 respectively. Hence the suggested RP-HPLC method can be used for routine analysis for flucloxacillin sodium in tablet dosage form.


Sign in / Sign up

Export Citation Format

Share Document