scholarly journals A Validated RP-HPLC Method for the Estimation of Pizotifen in Pharmaceutical Dosage Form

2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
M. V. Basaveswara Rao ◽  
A. V. D Nagendrakumar ◽  
Sushanta Maiti ◽  
N. Chandrasekhar

A simple, selective, linear, precise, and accurate RP-HPLC method was developed and validated for rapid assay of Pizotifen in pharmaceutical dosage form. Isocratic elution at a flow rate of 1.0 mL/min was employed on Chromosil C18 (250 mm × 4.6 mm, 5 μm) column at ambient temperature. The mobile phase consists of methanol : acetonitrile in the ratio of 10 : 90 v/v. The UV detection wavelength was 230 nm, and 20 μL sample was injected. The retention time for Pizotifen was 2.019 min. The percent RSD for accuracy of the method was found to be 0.2603%. The method was validated as per the ICH guidelines. The method can be successfully applied for routine analysis of Pizotifen in the rapid and reliable determination of Pizotifen in pharmaceutical dosage form.

INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (01) ◽  
pp. 35-40
Author(s):  
Rajesh Sharma ◽  
◽  
Mukesh C. Sharma ◽  
Gaurav Vijaywargiya

Chromatographic separation of paracetamol, aceclofenac and tramadol hydrochloride was performed on a Chromatopak C-18 column (25 cm x 4.6mm i.d. x 5µm) as stationary phase with a mobile phase composed of phosphate buffer pH 7.0: acetonitrile (65:35 V/V), pH 7.0 (adjusted with triethylamine) at flow rate of 1mL/min. Detection was carried out at 265 nm. The retention times of paracetamol, aceclofenac and Tramadol hydrochloride were found to be 2.7, 4.5 and 6.0 min, respectively. The proposed method was validated for linearity, accuracy, precision, LOD and LOQ. The method was found to be accurate, precise, specific, robust, and linear for the determination of paracetamol, aceclofenac and tramadol hydrochloride in pharmaceutical dosage form.


Author(s):  
V. N. V. KISHORE ◽  
G. V. RAMANA

Objective: Stability representing the RP-HPLC method was established for synchronized quantification of Tigecycline and its impurities. This method was confirmed for its applicability to both tablet dosage and bulk drug forms. Methods: Intended for an isocratic elution, a mobile phase containing methanol: 10 mmol Triethylamine Buffer mixture (75:25 v/v, pH 6.1) was used at 1 ml/min flow rate and Agilent ZORBAX Eclipse XDB C18 (250 mm × 4.6 mm, 5 μm) column. Results: At 231 nm as wavelength, high-pitched peaks of Tigecycline (Tig) and its impurities (1and2) were detected at 6.55, 8.73 and 4.87 min correspondingly. The linearity of tigecycline and its impurities (impurity-1 and 2 and) were estimated with ranging from 75–450 µg/ml for Tigecycline and 1–6 µg/ml for both impurity 1 and 2. The corresponding recognition limits (LOD and LOQ) of the tigecycline and its impurities were originated to be (1.37,0.047 and 0.071 µg/ml) and (4.15, 0.143 and 0.126 µg/ml). Conclusion: The technique was effectively stretched for stability signifying studies under different stress conditions. Justification of the method was done as per the current ICH guidelines.


2019 ◽  
Vol 9 (1) ◽  
pp. 170-174
Author(s):  
Anjali Bakshi ◽  
K Monika ◽  
Shweta Bhutada ◽  
M. Bhagvan Raju

A simple, selective, linear, precise, and accurate RP-HPLC method was developed and validated for the simultaneous estimation of Gabapentin & Methylcobalamin from bulk and formulation. Chromatographic separation was achieved Isocratically on an Inertsil C18 column (150x4.6, 5µ particle size) using a mobile phase Buffer: Acetonitrile in the ratio of 60:40 v/v. The flow rate was 1.0 ml/min, effluents were detected at 264 nm and 10µl of sample was injected. Retention time of Gabapentin & Methylcobalamin was found to be 2.7 and 4.13 min respectively. Linearity of the method was in the concentration range of 25-150 µg for Gabapentin & 0.125-0.750 µg for Methylcobalamin. Percent recoveries obtained for both the drugs were 100.00%. The percentage RSD for precision of the method was found to be less than 2%. The method was validated according to the ICH guidelines. The method developed was successfully applied for the analysis of simultaneous estimation of Gabapentin & Methylcobalamin tablets and was fairly good in comparison with other methods. Keywords: Gabapentin, Methylcobalamin, HPLC.


2011 ◽  
Vol 2011 ◽  
pp. 1-3 ◽  
Author(s):  
M. V. Basaveswara Rao ◽  
A. V. D. Nagendrakumar ◽  
Sushanta Maiti ◽  
Guttikonda Raja

A simple, selective, linear, precise, and accurate RP-HPLC method was developed and validated for the rapid assay of the Buspirone in tablet dosage form. Isocratic elution at a flow rate of 1.0 mL/min was employed on a symmetry C18 (250×4.6 mm, 5 μm in particle size) at ambient temperature. The mobile phase consisted of water : acetonitrile : methanol 45 : 35 : 20(V/V). The UV detection wavelength was 210 nm, and 20 μL sample was injected. The retention time for the Buspirone was 7.057 min. The percentage RSD for precision and accuracy of the method was found to be less than 2%. The method was validated as per the ICH guidelines. The method can be successfully applied for the routine analysis of Buspirone in tablet dosage form.


Author(s):  
Krishna Kishore Adireddy ◽  
Srinivasa Rao Baratam ◽  
Nagarjuna Hari Pratap S.

A simple, rapid, accurate and precise RP-HPLC method was developed and validated for the determination of Etelcalcetide in bulk and parentral dosage form. Quantification of the drug was achieved on Shimadzu HPLC comprising of LC- 20 AD binary gradient pump, a variable wavelength programmable SPD-20A detector and SCL system controller. C18G column (250 mm x 4.6 mm, 5 μ) as stationary phase with mobile phase consisting of acetonitrile: methanol :water in the ratio of 25: 45 :30 v/v. The method showed a good linear response in the concentration range of 3.75-22.5 μg/ml with correlation coefficient of 0.9999. The flow rate was maintained at 1.0 ml/min and effluents were monitored at 238 nm. The retention time of etelcalcetide was 6.201 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, solution stability, selectivity and sensitivity. The results obtained in the study were within the limits of ICH guidelines and hence this method can be used for the determination of etelcalcetide in bulk and parentral dosage form.


INDIAN DRUGS ◽  
2014 ◽  
Vol 51 (12) ◽  
pp. 32-36
Author(s):  
T. Vishalakhi ◽  
◽  
S. K Kumar ◽  
K Sujana ◽  
P Rani

A simple validated RP HPLC method for the estimation of rizatriptan benzoate in pharmaceutical dosage form and bulk was developed for routine analysis. This method was developed by selecting Agilent TC C18 (250 x 4.6 mm, 5 μ) column as stationary phase and acrylonibrile:water (45:55), pH adjusted to 3, as mobile phase. Flow rate of mobile phase was maintained at 4: 1 mL/min at ambient temperature throughout the experiment. Quantification was achieved with ultraviolet (DAD) detection at 220 nm. The retention time obtained for rizatriptan was 2.8 min. The detector response was linear in the concentration range of 2-25μg/mL. This method was validated and shown to be specific, sensitive, precise, linear, accurate, rugged and robust. Hence, this method can be applied for routine quality control of rizatriptan benzoate in dosage forms as well as in bulk drug.


Author(s):  
Sonalika Patro ◽  
S. Harshith Kumar ◽  
M. Barath kumar ◽  
E. Masthaniah ◽  
K. Sairam ◽  
...  

A Simple, accurate and precise method was developed and validated for the determination of flucloxacillin sodium in its tablet dosage form. The separation was eluted on xterra c18 column (4.6x150mm, 5micron) using a mixture of octane buffer and methanol as mobile phase in a ratio of (30:70) which was pumped through column at a flow rate of  1ml/min. Optimised wavelength for flucloxacillin was 237nm, the retention time was 2.305minutes and the percentage purity was found to be 98.14%. System suitability parameters such as theoretical plate and tailing factor for flucloxacillin sodium was found to be 2991.64 and 1.90 respectively, the proposed method was validated as per ICH guidelines (ICH, Q2 AND (R1)) the method was found to be linear at the concentration range of 20-100µg/ml and the correlation coefficient (r2) value was found to be 0.9994 percentage RSD for precision was 0.9% and percentage RSD for ruggedness was 0.5%. The precision study was precise, robust and repeatable. The LOD and LOQ values are 2.98 and 9.98 respectively. Hence the suggested RP-HPLC method can be used for routine analysis for flucloxacillin sodium in tablet dosage form.


Author(s):  
Abhishek Agrawal ◽  
Prem Kumar Bichala ◽  
Swapna Singh

RP-HPLC method was developed for the determination for the validation of Nitazoxanide and Ofloxacin in pharmaceutical dosage form. Chromatographic separation was performed on Develosil ODS HG-5 RP C18, 15x4.6mm, 5µm column, with mobile phase comprising of mixture of ACN: Methanol: Citric acid in the ratio of 50:45:5 v/v, at the flow rate 1.0ml/min and the detection was carried out at 296nm. The comprehensive forced stress testing has been carried out as per USP guidelines. The drug Nitazoxanide is subjected to synthetic Benzamide, and the drug Ofloxacin is subject to synthetic Fluoroquinolone. RP- HPLC method was developed to separate analyte from all other degradation peaks. The method was successfully validated as per ICH guidelines for the purpose of conducting studies of the analyte in quality control laboratory. The drug was subjected to different degradation conditions; it was found to be stable in all degradation conditions. The purposed HPLC method was found to be precise, specific, accurate, rapid and economical for the determination of Nitazoxanide and Ofloxacin in pharmaceutical dosage form. The sample recoveries in all formulations were in good agreement with their respective label claims and this method can be used for routine analysis. The linearity range was found to be 0-50 (µg/ml) for Nitazoxanide and 0-50 (µg/ml) for Ofloxacin. Calibration curve was plotted and correlation co-efficient for the drugs found to be 0.999 and 0.997. Hence the results obtained were within the limits.


2011 ◽  
Vol 8 (3) ◽  
pp. 1238-1245 ◽  
Author(s):  
G. Tulja Rani ◽  
D. Gowri Sankar ◽  
P. Kadgapathi ◽  
B. Satyanarayana

A simple, fast, precise, selective and accurate RP-HPLC method was developed and validated for the simultaneous determination of atenolol and indapamide from bulk and formulations. Chromatographic separation was achieved isocratically on a Waters C18 column (250×4.6 mm, 5 µ particle size) using a mobile phase, methanol and water (adjusted to pH 2.7 with 1% orthophosphoric acid) in the ratio of 80:20. The flow rate was 1 mL/min and effluent was detected at 230 nm. The retention time of atenolol and indapamide were 1.766 min and 3.407 min. respectively. Linearity was observed in the concentration range of 12.5-150 µg/mL for atenolol and 0.625-7.5 µg/mL for indapamide. Percent recoveries obtained for both the drugs were 99.74-100.06% and 98.65-99.98% respectively. The method was validated according to the ICH guidelines with respect to specificity, linearity, accuracy, precision and robustness. The method developed can be used for the routine analysis of atenolol and indapamide from their combined dosage form.


2018 ◽  
Vol 31 (1) ◽  
pp. 39-43 ◽  
Author(s):  
Thiyagarajan Deepan ◽  
Magharla Dasaratha Dhanaraju

AbstractA simple, fast, and highly selective RP-HPLC method was developed for the determination of Dapagliflozin (DAP) and Saxagliptin (SAX) in API and tablet dosage form. The separation was done using a Xterra RP18 (4.6×150 mm, 5 μm particle size) column with Acetonitrile: water (60:40). The isocratic elution mode at a flow rate of 1 mL/min, and the analytes were measured at 248 nm. The retention time for DAP and SAX were about 2.091 and 3.249 min, respectively. Calibration curves were found to be linear in the ranges of 100-500 μg/ml for DAP and 50-250 μg/ml for SAX, with correlation coefficients of 0.9998. The detection and quantification values for DAP was 3.0 and 9.98 μg/ml and SAX was 3.02 and 10 μg/ml respectively.


Sign in / Sign up

Export Citation Format

Share Document