scholarly journals The Development of a New Inhibition Kinetic Spectrophotometric Method for the Determination of Phenylhydrazine Based on its Inhibitory Effect on Oxidation of Methyl Red by Bromate in Micellar Medium

2010 ◽  
Vol 7 (4) ◽  
pp. 1591-1597
Author(s):  
Mohsen Keyvanfard

A new, simple, sensitive and selective kinetic spectrophotometric method was developed for the determination of trace amounts of phenylhydrazine over the range of 0.02-0.30 μg/mL. The method is based on the inhibitory effect of phenylhydrazine on the oxidation of methyl red by bromate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of methyl red at 518 nm with a fixed-time 0.5–2.0 min from initiation of the reaction..The relative standard deviation of 0.08 and 0.2 μg/mL phenylhydrazine was 1.7 and 2.4%, respectively. The method was applied to the determination of phenylhydrazine in water samples.

2012 ◽  
Vol 602-604 ◽  
pp. 1289-1293 ◽  
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

A spectrophotometric method was developed for the determination of trace Ru (III) is described, based on its catalytic effect of Ru (III) on the oxidation of dibromo caboxy arsenazo (DBCAA) by bromate in acidic and micellar medium at 100 °C. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of the catalytic reaction of DBCAA at 530 nm with a fixed-time method. The calibration curve for the recommended method was linear in the concentration range over 0.037–1.0 µg/L and the detection limit of the method for Ru (III) was 0.011 µg/L. The method was applied to the determination of Ru (III) in some ores and metallurgy products. The results are in good agreement with the recommend values with the relative standard deviation of 2.6 %–3.8 % and the recovery of 97.2 %–104.3 %.


2010 ◽  
Vol 7 (4) ◽  
pp. 1612-1620 ◽  
Author(s):  
M. Keyvanfard ◽  
N. Abedi

A new, simple, sensitive and selective kinetic spectrophotometric method was developed for the determination of ultra trace amounts of vanadium(V). The method is based on the catalytic effect of vanadium(V) on the oxidation of malachite green oxalate (MG) by bromate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of malachite green oxalate (MG) at 625 nm with a fixed-time method. The decrease in the absorbance of MG is proportional to the concentration of vanadium(V) in the range of 1-100 ng/mL with a fixed time of 0.5-2 min from the initiation of the reaction. The limit of detection is 0.71 ng/mL of vanadium(V). The relative standard deviation for the determination of 5, 30, 50 ng/mL of vanadium(V) was2.5% 2.6%, 2.4% and respectively. The method was applied to the determination of vanadium(V) in water samples.


2013 ◽  
Vol 2013 ◽  
pp. 1-5
Author(s):  
Mohsen Keyvanfard ◽  
Khadijeh Alizad ◽  
Razieh Shakeri

A new kinetic spectrophotometric method is described for the determination of ultratrace amounts of sodium cromoglycate (SCG). The method based on catalytic action of SCG on the oxidation of amaranth with periodate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of the amaranth at 518 nm, for the first 4 min from initiation of the reaction. Calibration curve was linear in the range of 4.0−36.0 ng mL−1SCG. The limit of detection is 2.7 ng mL−1SCG. The relative standard deviation (RSD) for ten replicate analyses of 12, 20, and 28 ng mL−1SCG was 0.40%, 0.32%, and 0.53%, respectively. The proposed method was used for the determination of SCG in biological samples.


2012 ◽  
Vol 204-208 ◽  
pp. 4067-4070 ◽  
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

A simple kinetic spectrophotometric method was developed for the determination of trace amounts of Ru (III). The method is based on the reduction of spadns by sodium hypophosphite (NaH2PO2) in micellar media. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of spadns at 515 nm with a fixed-time method. The decrease in the absorbance of spadns is proportional to the concentration of Ru (III) in the range 0.40–10.0 μg/L with a fixed time of 2.5–7.0 min from the initiation of the reaction. The limit of detection is 0.12 μg/L Ru (III). The relative standard deviation for the determination of 0.10 and 0.20 μg/25mL Ru (III) was 2.3 % and 2.0 %, respectively. The method was applied to the determination of Ru (III) in some ores and metallurgy products.


2012 ◽  
Vol 554-556 ◽  
pp. 926-933
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

A simple and sensitive kinetic spectrophotometric method for the determination of trace selenium (IV) is described, based on its catalytic effect on the reduction arsenazo III (AsA III) with sodium hypophosphite (NaH2PO2) in a solution of 0.02 mol/L sulfuric acid and in the presence of cationic micellar media. The reaction rate is monitored spectrophotometrically by measuring the decrease in absorbance of AsA III at 550 nm with a fixed-time method. The decrease in the absorbance of AsA III is proportional to the concentration of Se(IV) in the range 0.16–1.0 µg/L after a fixed time of 4–10 min from the initiation of the reaction. The limit of detection is 0.049 µg/L Se(IV). The influence of th e factors such as acidity, concentration of reactants, type and concentration of surfactants, reactive time, temperature and co-existing ions on the reaction is discussed. The optimum reaction conditions of reaction are established and some kinetic parameters are determined; the apparent activation energy of catalytic reaction is 59.51 kJ/mol. The relative standard deviation for eleven replicate determination of 0.02, and 0.01µg/25mL Se(IV) was 2.0 % and 2.4 %, respectively. Combined with sulphydryl dextrane gel (SDG) separation and enriching, the method has been successfully applied to the determination of Se (IV) in foodstuff and human hair samples with the relative standard deviation of 2.1 %–5.8 % and the recovery of 97.0 %–103.3 %, the results are in good agreement with those provided by ICP-AES method.


2010 ◽  
Vol 7 (3) ◽  
pp. 727-732
Author(s):  
Mohsen Keyvanfard

A new, simple, inexpensive and fast kinetic spectrophotometric method was developed for the determination of trace amounts of resorcinol over the range of 0.02-0.80 μg/mL. The method is based on the inhibitory effect of resorcinol on the formaldehyde catalyzed oxidation reaction of of cresyl violet by bromate in acidic media is reported. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of cresyl violet at 596 nm with a fixed-time 0.5–2.5 min from initiation of the reaction.The detection limit is 0.017 μg/mL and relative standard deviation of 0.1 and 0.5 μg/mL resorcinol for six replicate measurements was 2.6 and 2.9 %, respectively. The method was applied to the determination of resorcinol in water samples.


2012 ◽  
Vol 610-613 ◽  
pp. 446-451
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

Based on the oxidation of neutral red by KIO4 in 3.2×10-4 mol/L sulfuric acid solution, a simple kinetic spectrophotometric method was developed for the determination of trace amounts of Se(IV).The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of neutral red at 530 nm with a fixed-time method. The decrease in the absorbance of neutral red is proportional to the concentration of Se(IV) in the range 0.0–8.0 µg/L with a fixed time of 4–6 min from the initiation of the reaction. The limit of detection is 0.36 µg/L Se(IV). The influence of the factors such as acidity, concentration of reactants, reaction time, temperature and co-existing ions on the reaction is discussed. The optimum conditions of reaction are established and some kinetic parameters are determined. The apparent activation energy of catalytic reaction is 81.60 kJ/mol. The relative standard deviation for the determination of 0.1 and 0.2 µg/mL Se(IV) was 2.1 and 1.9 %, respectively. The method has been successfully applied to the determination of Se (IV) in tea and human hair samples with the relative standard deviation of 0.33 %–1.5 % and the recovery of 97.5 %–103.5 %.


2012 ◽  
Vol 538-541 ◽  
pp. 2358-2363 ◽  
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

Based on the oxidation of acid chrome blue K (ACBK) by hydrogen peroxide in 0.002 mol/L sulfuric acid solution, while 1,10-phenanthroline (phen) acts as an activator, a simple kinetic spectrophotometric method was developed for the determination of trace amounts of Se(IV).The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of ACBK at 524 nm with a fixed-time method. The decrease in the absorbance of ACBK is proportional to the concentration of Se (IV) in the range 0.06–1.0 µg/L with a fixed time of 4–10 min from the initiation of the reaction. The limit of detection is 0.018 µg/L Se (IV). The influence of the factors such as acidity, concentration of reactants, reaction time, temperature and co-existing ions on the reaction is discussed. The optimum conditions of reaction are established and some kinetic parameters are determined. The apparent activation energy of catalytic reaction is 62.30 kJ/mol. The relative standard deviation for 11 replicate determination of 0.01 and 0.02 µg/25mL selenium (III) was calculated to be 2.3 % and 2.0 %, respectively. Combined with sulphydryl dextrane gel (SDG) separation and enriching, the method has been successfully applied to the determination of Se (IV) in foodstuff samples with the relative standard deviation of 1.1 %–3.7 % and the recovery of 99.0 %–104.0 %, the results are in good agreement with those provided by HG-AAS method.


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Masoud Reza Shishehbore ◽  
Ali Sheibani ◽  
Masoumeh Eslami

A simple, selective, and inexpensive kinetic method was developed for the determination of hydrazine based on its inhibitory effect on the thionine-bromate system in sulfuric acid media. The reaction was monitored spectrophotometrically at 601 nm by a fixed time method. The effect of different parameters such as concentration of reactants, ionic strength, temperature, and time on the rate of reaction was investigated, and the optimum conditions were obtained. Under optimum conditions, the calibration curve was linear in the concentration range from 0.8–23.0 μg mL−1of hydrazine, and the detection limit of the method was 0.22 μg mL−1. The relative standard deviation for five replicate determinations of 1.0 μg mL−1of hydrazine was 0.74%. The potential of interfering effect of foreign species on the hydrazine determination was studied. The proposed method was successfully applied for the determination of hydrazine in different water samples.


2012 ◽  
Vol 217-219 ◽  
pp. 2397-2401 ◽  
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

A simple catalytic kinetic spectrophotometric method was developed for the determination of trace Ru (III) in the range of 0.033–1.00 μg/L. The method is based on the catalytic effect of Ru (III) on the oxidation of rhodamine 6G (Rh 6G) by bromate in micellar media. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of Rh 6G at 520 nm with a fixed-time method. The limit of detection is 0.010 μg/L Ru (III). The relative standard deviation for the determination of 0.010 and 0.020 μg/25mL Ru (III) was 2.9 % and 2.5 %, respectively. The method was applied to the determination of Ru (III) in some ores and metallurgy products.


Sign in / Sign up

Export Citation Format

Share Document