A Simple and Sensitive Spectrophotometric Method for the Determination of Trace Ruthenium with its Catalytic Effect on the Oxidation of Rhodamine 6G by KBrO3 in Micellar Media

2012 ◽  
Vol 217-219 ◽  
pp. 2397-2401 ◽  
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

A simple catalytic kinetic spectrophotometric method was developed for the determination of trace Ru (III) in the range of 0.033–1.00 μg/L. The method is based on the catalytic effect of Ru (III) on the oxidation of rhodamine 6G (Rh 6G) by bromate in micellar media. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of Rh 6G at 520 nm with a fixed-time method. The limit of detection is 0.010 μg/L Ru (III). The relative standard deviation for the determination of 0.010 and 0.020 μg/25mL Ru (III) was 2.9 % and 2.5 %, respectively. The method was applied to the determination of Ru (III) in some ores and metallurgy products.

2012 ◽  
Vol 204-208 ◽  
pp. 4067-4070 ◽  
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

A simple kinetic spectrophotometric method was developed for the determination of trace amounts of Ru (III). The method is based on the reduction of spadns by sodium hypophosphite (NaH2PO2) in micellar media. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of spadns at 515 nm with a fixed-time method. The decrease in the absorbance of spadns is proportional to the concentration of Ru (III) in the range 0.40–10.0 μg/L with a fixed time of 2.5–7.0 min from the initiation of the reaction. The limit of detection is 0.12 μg/L Ru (III). The relative standard deviation for the determination of 0.10 and 0.20 μg/25mL Ru (III) was 2.3 % and 2.0 %, respectively. The method was applied to the determination of Ru (III) in some ores and metallurgy products.


2010 ◽  
Vol 7 (4) ◽  
pp. 1612-1620 ◽  
Author(s):  
M. Keyvanfard ◽  
N. Abedi

A new, simple, sensitive and selective kinetic spectrophotometric method was developed for the determination of ultra trace amounts of vanadium(V). The method is based on the catalytic effect of vanadium(V) on the oxidation of malachite green oxalate (MG) by bromate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of malachite green oxalate (MG) at 625 nm with a fixed-time method. The decrease in the absorbance of MG is proportional to the concentration of vanadium(V) in the range of 1-100 ng/mL with a fixed time of 0.5-2 min from the initiation of the reaction. The limit of detection is 0.71 ng/mL of vanadium(V). The relative standard deviation for the determination of 5, 30, 50 ng/mL of vanadium(V) was2.5% 2.6%, 2.4% and respectively. The method was applied to the determination of vanadium(V) in water samples.


2012 ◽  
Vol 554-556 ◽  
pp. 926-933
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

A simple and sensitive kinetic spectrophotometric method for the determination of trace selenium (IV) is described, based on its catalytic effect on the reduction arsenazo III (AsA III) with sodium hypophosphite (NaH2PO2) in a solution of 0.02 mol/L sulfuric acid and in the presence of cationic micellar media. The reaction rate is monitored spectrophotometrically by measuring the decrease in absorbance of AsA III at 550 nm with a fixed-time method. The decrease in the absorbance of AsA III is proportional to the concentration of Se(IV) in the range 0.16–1.0 µg/L after a fixed time of 4–10 min from the initiation of the reaction. The limit of detection is 0.049 µg/L Se(IV). The influence of th e factors such as acidity, concentration of reactants, type and concentration of surfactants, reactive time, temperature and co-existing ions on the reaction is discussed. The optimum reaction conditions of reaction are established and some kinetic parameters are determined; the apparent activation energy of catalytic reaction is 59.51 kJ/mol. The relative standard deviation for eleven replicate determination of 0.02, and 0.01µg/25mL Se(IV) was 2.0 % and 2.4 %, respectively. Combined with sulphydryl dextrane gel (SDG) separation and enriching, the method has been successfully applied to the determination of Se (IV) in foodstuff and human hair samples with the relative standard deviation of 2.1 %–5.8 % and the recovery of 97.0 %–103.3 %, the results are in good agreement with those provided by ICP-AES method.


2012 ◽  
Vol 602-604 ◽  
pp. 1289-1293 ◽  
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

A spectrophotometric method was developed for the determination of trace Ru (III) is described, based on its catalytic effect of Ru (III) on the oxidation of dibromo caboxy arsenazo (DBCAA) by bromate in acidic and micellar medium at 100 °C. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of the catalytic reaction of DBCAA at 530 nm with a fixed-time method. The calibration curve for the recommended method was linear in the concentration range over 0.037–1.0 µg/L and the detection limit of the method for Ru (III) was 0.011 µg/L. The method was applied to the determination of Ru (III) in some ores and metallurgy products. The results are in good agreement with the recommend values with the relative standard deviation of 2.6 %–3.8 % and the recovery of 97.2 %–104.3 %.


2013 ◽  
Vol 2013 ◽  
pp. 1-5
Author(s):  
Mohsen Keyvanfard ◽  
Khadijeh Alizad ◽  
Razieh Shakeri

A new kinetic spectrophotometric method is described for the determination of ultratrace amounts of sodium cromoglycate (SCG). The method based on catalytic action of SCG on the oxidation of amaranth with periodate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of the amaranth at 518 nm, for the first 4 min from initiation of the reaction. Calibration curve was linear in the range of 4.0−36.0 ng mL−1SCG. The limit of detection is 2.7 ng mL−1SCG. The relative standard deviation (RSD) for ten replicate analyses of 12, 20, and 28 ng mL−1SCG was 0.40%, 0.32%, and 0.53%, respectively. The proposed method was used for the determination of SCG in biological samples.


2014 ◽  
Vol 2014 ◽  
pp. 1-12 ◽  
Author(s):  
Mohammed G. Abdel Wahed ◽  
Ragaa El Sheikh ◽  
Ayman A. Gouda ◽  
Sayed Abou Taleb

Simple, sensitive, and accurate kinetic spectrophotometric method was proposed for the determination of gemifloxacin mesylate (GMF) and moxifloxacin hydrochloride (MOX) in pure forms and pharmaceutical preparations (tablets). The method is based on coupling the studied drugs with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl) in the presence of alkaline borate buffer. Spectrophotometric measurement was achieved by recording the absorbance at 466 and 464 nm for GMF and MOX, respectively, after a fixed time of 20 and 15 min on a water bath adjusted at 70 ± 5°C for both drugs. The different experimental parameters affecting the development and stability of the color were carefully studied and optimized. The absorbance-concentration plots were linear over the ranges 0.5–8.0 and 2.0–12 μg mL−1for GMF and MOX, respectively. The limit of detection of the kinetic method was about 0.12 (2.47 × 10−7 M) and 0.36 (8.22 × 10−7 M) μg mL−1for GMF and MOX, respectively. The proposed methods have been applied and validated successfully with percentage relative standard deviation (RSD% ≤ 0.52) as precision and percentage relative error (RE% ≤ 1.33) as accuracy. The robustness of the proposed method was examined with recovery values that were 97.5–100.5 ± 1.3–1.9%. Statistical comparison of the results with the reference spectrophotometric methods shows excellent agreement and indicates no significant difference in accuracy or precision.


2019 ◽  
Vol 16 (3) ◽  
pp. 0595
Author(s):  
ALmashhadani Et al.

          Simple, cheap, sensitive, and accurate kinetic- spectrophotometric method has been developed for the determination of naringenin in pure and supplements formulations. The method is based on the formation of Prussian blue. The product dye exhibits a maximum absorbance at 707 nm. The calibration graph of naringenin was linear over the range 0.3 to 10 µg ml-1 for the fixed time method (at 15 min) with a correlation coefficient (r) and percentage linearity (r2%) were of 0.9995 and 99.90 %, respectively, while the limit of detection LOD was 0.041 µg ml-1. The method was successfully applied for the determination of naringenin in supplements with satisfactory results.


2012 ◽  
Vol 610-613 ◽  
pp. 446-451
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

Based on the oxidation of neutral red by KIO4 in 3.2×10-4 mol/L sulfuric acid solution, a simple kinetic spectrophotometric method was developed for the determination of trace amounts of Se(IV).The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of neutral red at 530 nm with a fixed-time method. The decrease in the absorbance of neutral red is proportional to the concentration of Se(IV) in the range 0.0–8.0 µg/L with a fixed time of 4–6 min from the initiation of the reaction. The limit of detection is 0.36 µg/L Se(IV). The influence of the factors such as acidity, concentration of reactants, reaction time, temperature and co-existing ions on the reaction is discussed. The optimum conditions of reaction are established and some kinetic parameters are determined. The apparent activation energy of catalytic reaction is 81.60 kJ/mol. The relative standard deviation for the determination of 0.1 and 0.2 µg/mL Se(IV) was 2.1 and 1.9 %, respectively. The method has been successfully applied to the determination of Se (IV) in tea and human hair samples with the relative standard deviation of 0.33 %–1.5 % and the recovery of 97.5 %–103.5 %.


2012 ◽  
Vol 538-541 ◽  
pp. 2358-2363 ◽  
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

Based on the oxidation of acid chrome blue K (ACBK) by hydrogen peroxide in 0.002 mol/L sulfuric acid solution, while 1,10-phenanthroline (phen) acts as an activator, a simple kinetic spectrophotometric method was developed for the determination of trace amounts of Se(IV).The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of ACBK at 524 nm with a fixed-time method. The decrease in the absorbance of ACBK is proportional to the concentration of Se (IV) in the range 0.06–1.0 µg/L with a fixed time of 4–10 min from the initiation of the reaction. The limit of detection is 0.018 µg/L Se (IV). The influence of the factors such as acidity, concentration of reactants, reaction time, temperature and co-existing ions on the reaction is discussed. The optimum conditions of reaction are established and some kinetic parameters are determined. The apparent activation energy of catalytic reaction is 62.30 kJ/mol. The relative standard deviation for 11 replicate determination of 0.01 and 0.02 µg/25mL selenium (III) was calculated to be 2.3 % and 2.0 %, respectively. Combined with sulphydryl dextrane gel (SDG) separation and enriching, the method has been successfully applied to the determination of Se (IV) in foodstuff samples with the relative standard deviation of 1.1 %–3.7 % and the recovery of 99.0 %–104.0 %, the results are in good agreement with those provided by HG-AAS method.


Sign in / Sign up

Export Citation Format

Share Document