scholarly journals Molecular Biologic Approach to the Diagnosis of Pancreatic Carcinoma Using Specimens Obtained by EUS-Guided Fine Needle Aspiration

2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
Kiyohito Kato ◽  
Hideki Kamada ◽  
Takayuki Fujimori ◽  
Yuuichi Aritomo ◽  
Masahiro Ono ◽  
...  

We review the utility of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA), a rapid, safe, cost-effective, and accurate diagnostic modality for evaluating pancreatic tumors. EUS-FNA is currently used for the diagnosis and staging of pancreatic tumors. The sensitivity of EUS-FNA for pancreatic malignancy ranges from 75% to 94%, and its specificity approaches 100% in most studies. However, EUS-FNA has some limitations in the diagnosis of well-differentiated or early-stage cancers. Recent evidence suggests that molecular biological analysis using specimens obtained by EUS-FNA improves diagnostic sensitivity and specificity, especially in borderline cytological cases. It was also reported that additional information regarding patient response to chemotherapy, surgical resectability, time to metastasis, and overall survival was acquired from the genetic analysis of specimens obtained by EUS-FNA. Other studies have revealed that the analysis of KRAS, MUC, p53, p16, S100P, SMAD4, and microRNAs is helpful in making the diagnosis of pancreatic carcinoma. In this paper, we describe the present state of genetic diagnostic techniques for use with EUS-FNA samples in pancreatic diseases. We also discuss the role of molecular biological analyses for the diagnosis of pancreatic carcinoma.

2021 ◽  
pp. 69-70
Author(s):  
Ragini Kumari ◽  
Vikash M. Harinandan ◽  
Kunal Shankar ◽  
Ajit Kumar Chaudhary ◽  
Debarshi Jana

Background: FNAC is considered an important procedure in the diagnosis of bone tumors because of its high accuracy. In our study FNA was performed in patients to study the role of FNAC in the diagnosis of bone tumors and to evaluate its usefulness as a diagnostic modality. Methods: Fine needle aspiration was performed on 54 patients whose age ranged between 5 – 75 years with a male to female ratio 1.84 :1 presented with various bone lesions. The bone lesions included 42 (78%) primary lesions, 5 (9.3%) metastatic deposits and 7 (12. 7%) malignancy of related structures involving the bone. Results: 47 biopsy specimens were available for cytohistological correlation and cytological ndings of 45 cases correlated with histopathology. The overall diagnostic accuracy was 95.92%, with 100% sensitivity and specicity. The predictive values of positive as well as negative test were 100%. Conclusions:Thus FNAwas found to be a safe and an extremely useful, rapid method in the preliminary diagnosis of bone lesions.


2017 ◽  
Vol 30 (6) ◽  
pp. 472
Author(s):  
Vera Fernandes ◽  
Tânia Pereira ◽  
Catarina Eloy

Introduction: The fine-needle aspiration has a significant role in assessing the malignancy risk of thyroid nodules. There is uncertainty regarding the value of repeat fine-needle aspiration in benign nodules. This study aims to evaluate the concordance of results in consecutive fine-needle aspiration and to study the relevance of repetition in benign results.Material and Methods: Retrospective study of the 4800 thyroid nodules fine-needle aspiration held in Instituto de Patologia e Imunologia Molecular da Universidade do Porto between January 1, 2014 and May 2, 2016. Of the initial sample, we selected the repeated fine-needle aspiration on the same nodule.Results: The first fine-needle aspiration result of the 309 nodules underwent revaluation was non-diagnostic in 103 (33.3%), benign in 120 (38.8%) and atypia/follicular lesion of undetermined significance in 86 (27.8%). The agreement between the first and second fine-needle aspiration was significantly higher in cases with an initial benign result (benign: 85.8%, non-diagnostic: 27.2% and atypia/ follicular lesion of undetermined significance: 17.4%, p < 0.005). The fine-needle aspiration repeating motifs in initially benign nodules (n = 78) were repetition suggestion in 58, nodule growth in 17 and suspicious ultrasonographic features in 3.Discussion: The fine-needle aspiration repetition in nodules with initial non-diagnostic and atypia/follicular lesion of undetermined significance result changed the initial diagnosis in a significant proportion of patients, modifying their therapeutic approach. The high concordance of results in initially benign nodules makes fine-needle aspiration repetition not cost-effective in most cases.Conclusion: The fine-needle aspiration should be repeated when the initial cytology result is non-diagnostic or atypia/follicular lesion of undetermined significance.


Author(s):  
Han-Yue Wang ◽  
◽  
Hao-Su Huang ◽  
Meng Wang ◽  
Jie Peng ◽  
...  

Background: Mass-Forming Chronic Pancreatitis (MFCP) is rare. Moreover, atypical MFCP is difficult to differentiate from Pancreatic Carcinoma (PC) in clinical manifestations, laboratory, and imaging examinations. Diagnosis could be supported by the pathological findings of focal inflammatory fibrosis without evidence of tumor in the pancreas. Case summary: A 52-year-old man had acute pancreatitis twice over 7 months. Amylase and lipase levels were three times higher than the normal range without any clinical symptoms. At the 6th month, the patient lost 15 kg of weight, and abdominal ultrasonography revealed pancreatic head space occupied. All the findings in multimodal imaging including computed tomography image, Magnetic Resonance (MR) imaging with MR cholangiopancreatography, and 18F-FDG positron emission tomography/computed tomography showed an irregular nodule with low density, low signal, and low echo in the head of the pancreas, which were lower than those in the normal pancreatic tissue. The proximal main pancreatic duct was truncated and stenosed, and the distal duct was dilated. Subsequently, he developed progressive painless jaundice, and the specific tumor marker levels were increased. Most of these manifestations were suggestive of the pancreatic malignant tumor; however, multiple specimen pathological findings obtained from laparotomy and endoscopic ultrasonography-guided fine-needle aspiration revealed focal chronic inflammation, fibrosis, and necrosis. Conclusion: This report describes a case of atypical MFCP mimicking PC at clinical presentation and laboratory findings, especially in multimodal imaging. However, the combination of atypical multimodal imaging features, which support MFCP rather than PC, and endoscopic ultrasonography-guided fine-needle aspiration are useful for improving the diagnostic rate of atypical MFCP and avoiding unnecessary surgery.


1998 ◽  
Vol 11 (2) ◽  
pp. 341-365 ◽  
Author(s):  
Celeste N. Powers

SUMMARY This review explores the role of the cytopathology laboratory in the detection and presumptive identification of microorganisms. Sample procurement by exfoliation, abrasion, and aspiration techniques, as well as a variety of cytopreparatory and staining methods, is reviewed. Emphasis is placed on the utility of fine-needle aspiration as a rapid, safe, and cost-effective diagnositic procedure. The role of rapid interpretation and specimen triage is also discussed. Cytomorphologic features and staining characteristics are presented for a spectrum of microorganisms potentially encountered in the cytopathology laboratory. Pitfalls in diagnosis and the usefulness of special stains and ancillary techniques are also evaluated. The importance of communication, collaboration, and clinical correlation is stressed.


Cancers ◽  
2019 ◽  
Vol 11 (4) ◽  
pp. 487 ◽  
Author(s):  
Jeongmin Lee ◽  
Hye Lim Park ◽  
Chan-Wook Jeong ◽  
Jeonghoon Ha ◽  
Kwanhoon Jo ◽  
...  

Fine needle aspiration cytology (FNAC) and washout thyroglobulin (Tg) measurements are the standard for evaluating a metastatic lymph node (LN) in thyroid cancer. However, patients rarely benefit from these procedures due to false results. This study aims to identify a reliable biomarker that significantly improves the diagnosis of metastatic LNs, in addition to FNAC and washout Tg. This study analyzed 130 LNs that were suspected to have metastases on thyroid ultrasonography, from June 2016 to December 2017. All subjects underwent FNAC, washout Tg measurements and a new biomarker, washout Cytokeratin fragment 21-1 (CYFRA 21-1) measurement. The final LN outcomes were confirmed by surgical histology, repeat FNAC, or follow-up image. The diagnostic values of the presence of washout CYFRA 21-1 for diagnosing metastatic LNs were evaluated according to final LN outcomes. Among the 130 LNs, 42 were metastatic lesions and 88 were benign. The washout CYFRA 21-1 levels were significantly higher in metastatic LNs than in benign LNs. In contrast to the findings of washout Tg, washout CYFRA 21-1 showed little overlap between benign and malignant LNs, and its diagnostic cutoff values were not affected by surgery. The combinations of FNAC and washout CYFRA 21-1 showed higher sensitivity (91.9%), specificity (96.5%), negative predictive value (98.8%), and diagnostic accuracy (94.2%) than FNAC with washout Tg. The combination of FNAC, washout Tg, and washout CYFRA 21-1 showed the best sensitivity (98.8%). When washout CYFRA 21-1 was applied to the discordant results that were observed between FNAC and washout Tg, 20 of 22 LNs were correctly diagnosed. Washout CYFRA 21-1 measurements in thyroid LNs provide a diagnostic modality.


2016 ◽  
Vol 60 (5) ◽  
pp. 465-474 ◽  
Author(s):  
Maral Mokhatri ◽  
Golsa Shekarkhar ◽  
Zahra Sarraf

Objective: In gynecology, fine-needle aspiration (FNA) has an overall accuracy of 94.5% in differentiation between benign and malignant tumors. The purpose of this study was to determine reliable cytological criteria for categorizing ovarian masses into benign and malignant categories, their subtypes, and also to evaluate FNA accuracy in the diagnosis of ovarian tumors in relation to histopathological findings. Study Design: A prospective study was performed on all patients with a preoperative diagnosis of ovarian tumor who were referred to our hospital between August 2013 and August 2015. During surgery, FNA was performed using an 18-gauge needle by a pathologist. Aspirated material was spread on clean glass slides and stained with Papanicolaou and Wright-Giemsa stains. The cytological findings and results were compared with the histological diagnosis. Results: Of the 81 cases in this study, there was a discrepancy between the cytological and histological diagnosis in 9 cases. The overall cytological diagnostic accuracy in our study was 88.9% with a sensitivity and specificity of 78.1 and 95.5%, respectively. Conclusion: FNA of an ovarian mass is a minimally invasive procedure with acceptable diagnostic accuracy, especially when differentiating between benign and malignant lesions, and can be considered as a useful diagnostic modality for choosing an appropriate management course.


Sign in / Sign up

Export Citation Format

Share Document