A transmission line model is used to design corporate-fed multilayered bow-tie antennas arrays; the simulated antennas arrays are designed to resonate at the frequencies 2.4 GHz, 5 GHz, and 8 GHz corresponding to RFID, WIFI, and radars applications. The contribution of this paper consists of modeling multilayer bow-tie antenna array fed through an aperture using transmission line model. The transmission line model is simple and precise and allows taking into account the whole geometrical, electrical, and technological characteristics of the antennas arrays. The proposed transmission line model showed its interest in the design of different multilayered bow-tie antennas and predicted the correct resonance frequency for different applications in telecommunications. To validate the proposed transmission line model, the simulation results obtained are compared with those obtained by the method of moments. The results of simulations are presented and discussed. Using this transmission line approach, the resonant frequency, input impedance, and return loss can be determined simultaneously. The paper reports several simulation results that confirm the validity of the developed model. The obtained results are then presented and discussed.

Author(s):  
Seyyed Sajjad Sajjadi ◽  
Saeed Reza Ostadzadeh

Purpose The purpose of this paper is to investigate the ionization and dispersion effects in combination with the inhomogeneity of soil simultaneously on the effective lengths of counterpoise wires. Design/methodology/approach Improved multi-conductor transmission line model is used for computing effective length of counterpoise wires considering all aspects of soils. Findings The simulation results show that the ionization and dispersion effects simultaneously results in placing the effective length between situations where only one effect is considered. Also, predicting formulae for effective length of counterpoise wires considering all effects are proposed. Originality/value A sensitivity analysis on the effective lengths of counterpoise wires considering all aspects of soils is carried out.


2014 ◽  
Vol 672-674 ◽  
pp. 799-802
Author(s):  
Xiao Gang Li ◽  
Li Xue Li ◽  
Yi Hui Zheng ◽  
Xin Wang ◽  
Jian You Yu ◽  
...  

Lightning overvoltage often leads to transmission lines trip, which is the weak link of power system. In this paper, 110-kV transmission line model is studied on the basis of the EMTP software. Several simulation models are established for back flashover lightning, induced lightning, shield failure. The transient process of lightning stroke is studied. According to the contrast of simulation results of three kinds of lightning, a set of discriminant basis to distinguish lightning on transmission line is put forward.


Transmission Line model are an important role in the electrical power supply. Modeling of such system remains a challenge for simulations are necessary for designing and controlling modern power systems.In order to analyze the numerical approach for a benchmark collection Comprehensive of some needful real-world examples, which can be utilized to evaluate and compare mathematical approaches for model reduction. The approach is based on retaining the dominant modes of the system and truncation comparatively the less significant once.as the reduced order model has been derived from retaining the dominate modes of the large-scale stable system, the reduction preserves the stability. The strong demerit of the many MOR methods is that, the steady state values of the reduced order model does not match with the higher order systems. This drawback has been try to eliminated through the Different MOR method using sssMOR tools. This makes it possible for a new assessment of the error system Offered that the Observability Gramian of the original system has as soon as been thought about, an H∞ and H2 error bound can be calculated with minimal numerical effort for any minimized model attributable to The reduced order model (ROM) of a large-scale dynamical system is essential to effortlessness the study of the system utilizing approximation Algorithms. The response evaluation is considered in terms of response constraints and graphical assessments. the application of Approximation methods is offered for arising ROM of the large-scale LTI systems which consist of benchmark problems. The time response of approximated system, assessed by the proposed method, is also shown which is excellent matching of the response of original system when compared to the response of other existing approaches .


1990 ◽  
Vol 26 (2) ◽  
pp. 148 ◽  
Author(s):  
D. Kinowski ◽  
C. Seguinot ◽  
P. Pribetich ◽  
P. Kennis

Sign in / Sign up

Export Citation Format

Share Document