scholarly journals Development and Validation of a LC/MS/MS Method for the Determination of Duloxetine in Human Plasma and Its Application to Pharmacokinetic Study

2012 ◽  
Vol 9 (2) ◽  
pp. 899-911 ◽  
Author(s):  
D. Chandrapal Reddy ◽  
A. T. Bapuji ◽  
V. Surayanarayana Rao ◽  
V. Himabindu ◽  
D. Rama Raju ◽  
...  

A selective, high sensitive and high throughput liquid chromatography-tandem mass spectrometry (LC-ESI-MS/MS) method has been developed and validated for the chromatographic separation and quantitation of duloxetine in human EDTA plasma using fluoxetine (IS) as an internal standard. Analyte and IS were extracted from human plasma by liquid-liquid extraction using MTBE-n Hexane (80:20).The eluted samples were chromatographed on X-terra RP8 (50 mmx4.6 mm, 5 μm particle size) column by using mixture of 30 mM ammonium formate (pH-5.0±0.05) and acetonitrile as an isocratic mobile phase at a flow rate of 0.40 mL/min and analyzed by mass spectrometer in the multiple reaction monitoring (MRM) using the respective m/z 298.08→154.0 for duloxetine and 310.02→148.07 for IS. The linearity of the response/ concentration curve was established in human plasma over the concentration range 0.100-100.017 ng/mL. The lower detection limit (LOD,S/N>3) was 0.04 ng/mL and the lower limit of quantization (LOQ,S/N>10) was 0.100 ng/mL. This LC-MS/MS method was validated with Intra-batch and Inter-batch precision of 5.21-7.02. The Intra-batch and Inter-batch accuracy was 97.14-103.50 respectively. Recovery of duloxetine in human plasma is 80.31% and ISTD recovery is 81.09%. The main pharmacokinetic parameters were Tmax(hr) = (7.25±1.581), Cmax(ng/mL) (44.594±18.599), AUC0→t, = (984.702±526.502) and AUC0→∞, (1027.147±572.790) respectively.

INDIAN DRUGS ◽  
2020 ◽  
Vol 57 (06) ◽  
pp. 32-38
Author(s):  
H. Potluri ◽  

A specific and sensitive method of liquid chromatography–tandem mass spectrometry was demonstrated for the experimental determination of venetoclax in human plasma utilising venetoclax-D8 as an internal standard. The column Xbridge C18, 50 × 4.6mm, 5 µm was used for attaining chromatographic separation by utilising 10mM ammonium formate and methanol as isocratic mobile phase in the composition ratio of 20:80 (V/V). The flow-rate selected was 0.7ml/min. Venetoclax and venetoclax-D8 are identified in multiple reaction monitoring (MRM) positive mode with proton adducts at m/z 869.53 →553.21 and m/z 877.14 → 553.23, respectively. For the successful extraction of drug as well as internal standard, liquid-liquid extraction technique was efficiently utilised. The developed technique was established in a linear concentration range of 5.0-5000.0 pg/ml along with correlation coefficient (r2) of 0.9994. Intra and inter-day precisions were found to be 0.7 to 1.90% and 0.7 to 2.0 % for venetoclax and venetoclax-D8, respectively. Accuracy was found to be within 98.6 to 101.99% and 99.17 to 101.14 % for venetoclax and venetoclax-D8, respectively. It was observed that throughout the bench top studies, post-operative stability studies and freeze-thawing cycles, venetoclax retained stability.


Author(s):  
Revathi Naga Lakshmi Ponnuri ◽  
Prahlad Pragallapati ◽  
Ravindra N ◽  
Venkata Basaveswara Rao Mandava

  Objective: The main objective of the work was to develop a straightforward, fast and selective liquid chromatography/tandem mass spectrometry (LC-MS/MS) assay for determination of pioglitazone (PG), keto pioglitazone (KPG), and hydroxy pioglitazone (HPG) in human plasma and to validate as per recent guidelines.Methods: Analyte and the internal standard (IS) were extracted from plasma through liquid-liquid extraction and chromatographed on a Xterra RP18, 100×4.6, 5 μ column using methanol: acetonitrile mixture and 10 mM Ammonium formate buffer (70:30, v/v) as the mobile phase at a flow rate of 0.7 mL/min. The API-3200 Q Trap LC-MS/MS instrument in multiple reaction monitoring mode was used for detection. Diphenhydramine was utilized as IS.Results: The linearity was established in the concentration range of 20.15-1007.58 ng/mL for PG, 20.35-1017.58 ng/mL for KPG, and 19.68-491.22 ng/mL for HPG in human plasma. All the validation parameters were well within the acceptance limits.Conclusion: A new simple LC-MS/MS method was developed for the determination of PG, KPG, and HPG in human plasma. This method can be easily applied for the estimation of pharmacokinetic parameters of PG, KPG, and HPG.


2019 ◽  
Vol 57 (8) ◽  
pp. 751-757
Author(s):  
Jiake He ◽  
Ning Li ◽  
Jiaqiu Xu ◽  
Jing Zhu ◽  
Yang Yu ◽  
...  

Abstract A simple, sensitive, specific, accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for determination of chlorzoxazone in human plasma was developed and validated to evaluate the pharmacokinetic characteristics of chlorzoxazone test or reference formulation. Sample preparation was achieved by one step protein precipitation and dilution with acetontrile. The chromatographic separation was performed at 40°C with a gradient mobile phase (0.3 mL/min) and a Shimadzu VP-ODS C18 analytical column (column size: 150 × 2.0 mm). TSQ quantum access triple-quadrapole MS/MS detection was operated in a negative mode by multiple reaction monitoring. Ion transitions at m/z 168.0→132.1 for chlorzoxazone and m/z 451.3→379.3 for repaglinide (internal standard) were used for the LC-MS/MS analysis. The calibration was linear (r ≥ 0.995) over the tested concentration range of 0.2–20 μg/mL for chlorzoxazone in plasma. Precision, accuracy, recovery, matrix effect and stability for chlorzoxazone were evaluated and were excellent within the range of tested concentrations. This method was successfully applied to a bioequivalence study in 20 healthy Chinese volunteers. This method could also contribute to the personalized medication and therapeutic drug monitoring of chlorzoxazone.


Bioanalysis ◽  
2019 ◽  
Vol 11 (19) ◽  
pp. 1767-1776
Author(s):  
Kiran R Patil ◽  
Ravindra D Yeole ◽  
Marcel de Zwart ◽  
Peter Pruim

Aim: A sensitive method to quantify nafithromycin and its N-desmethyl metabolite in human plasma was necessary for Phase I pharmacokinetic studies. Methodology: A precise and accurate LC–MS/MS bioanalytical method has been developed and validated for the simultaneous quantification of nafithromycin (NFT, WCK 4873) and N-desmethyl metabolite (M1, WCK 4978) in human plasma. Clarithromycin was used as an internal standard. Protein precipitation technique was used as sample preparation approach. The calibration curve was linear (r ≥ 0.99) over the concentration range of 10–5000 ng/ml for NFT and M1. Method was validated as per US FDA guideline. Conclusion: The proposed method was successfully applied for determination of plasma levels of the NFT and M1 during Phase I clinical studies.


Author(s):  
Xiaorong Wu ◽  
Yankai Wang ◽  
Binbin Liang ◽  
Honghai Wu ◽  
Liying Wu ◽  
...  

AbstractAn ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC–MS/MS) method was developed to determine the fenofibric acid (FA) in human plasma and applied to a pharmacokinetic study of fenofibrate tablet (Lipanthyl® supra, 160 mg) on Chinese subjects which had not been reported. Bezafibrate was used as an internal standard (IS), and the plasma samples were precipitated by methanol. Multiple reaction monitoring (MRM) mode was used to quantitatively analyzed FA m/z 317.2 → 230.7 and the IS m/z 360.0 → 274.0 in the electrospray ionization (ESI) negative interface. The calibration curves were linear over the range of 50–30,000  ng/mL (r2  ≥  0.996). The intra-day and inter-day precision (coefficient of variation, CV%) was less than 2.7 and 2.5%, respectively. The accuracy (relative error, RE%) ranged from −4.5 to 6.9%. The average recovery was higher than 86.2%, and the matrix effect was between 95.32 and 110.55%. The simple, rapid, and selectivity method was successfully applied to the pharmacokinetic study of fenofibrate tablets on Chinese subjects.


Sign in / Sign up

Export Citation Format