scholarly journals Review of Physical Based Monitoring Techniques for Condition Assessment of Corrosion in Reinforced Concrete

2013 ◽  
Vol 2013 ◽  
pp. 1-14 ◽  
Author(s):  
Ying Lei ◽  
Zhu-Peng Zheng

Monitoring the condition of steel corrosion in reinforced concrete (RC) is imperative for structural durability. In the past decades, many electrochemistry based techniques have been developed for monitoring steel corrosion. However, these electrochemistry techniques can only assess steel corrosion through monitoring the surrounding concrete medium. As alternative tools, some physical based techniques have been proposed for accurate condition assessment of steel corrosion through direct measurements on embedded steels. In this paper, some physical based monitoring techniques developed in the last decade for condition assessment of steel corrosion in RC are reviewed. In particular, techniques based on ultrasonic guided wave (UGW) and Fiber Bragg grating (FBG) are emphasized. UGW based technique is first reviewed, including important characters of UGW, corrosion monitoring mechanism and feature extraction, monitoring corrosion induced deboning, pitting, interface roughness, and influence factors. Subsequently, FBG for monitoring corrosion in RC is reviewed. The studies and application of the FBG based corrosion sensor developed by the authors are presented. Other physical techniques for monitoring corrosion in RC are also introduced. Finally, the challenges and future trends in the development of physical based monitoring techniques for condition assessment of steel corrosion in RC are put forward.

2014 ◽  
Vol 525 ◽  
pp. 499-503
Author(s):  
Zhu Peng Zheng

Monitoring the condition of steel corrosion in reinforced concrete (RC) is imperative for ensuring structural serviceability and durability of RC structures. The techniques based on ultrasonic guided wave (UGW) gain more and more popularities as they have many advantages for monitoring corrosion in reinforced concrete. In this paper, UGW based monitoring techniques in the past decade are reviewed, including corrosion monitoring mechanism and feature extraction, monitoring corrosion induced deboning, monitoring pitting corrosion, monitoring corrosion induced interface roughness. Finally, the challenges and future trends in the development of UGW based monitoring techniques for condition assessment of corrosion inreinforced concrete are put forward in this paper.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Zhupeng Zheng ◽  
Ying Lei ◽  
Xin Xue

Numerical simulation based on finite element method is conducted to predict the location of pitting corrosion in reinforced concrete. Simulation results show that it is feasible to predict corrosion monitoring based on ultrasonic guided wave in reinforced concrete, and wavelet analysis can be used for the extremely weak signal of guided waves due to energy leaking into concrete. The characteristic of time-frequency localization of wavelet transform is adopted in the corrosion monitoring of reinforced concrete. Guided waves can be successfully used to identify corrosion defects in reinforced concrete with the analysis of suitable wavelet-based function and its scale.


2014 ◽  
Vol 501-504 ◽  
pp. 881-884
Author(s):  
Zhu Peng Zheng ◽  
Yu Song

It is imperative to develop effective techniques to monitor the condition of steel corrosion in reinforced concrete (RC) for ensuring structural serviceability and durability. In the past decade, some physical based techniques have been proposed as alternative tools for monitoring corrosion. These physical based monitoring techniques can conduct accurate condition assessment of steel corrosion through direct measurements on embedded steels. In this paper, some primary physical based monitoring techniques for condition assessment of steel corrosion in reinforced concrete in the recent years are presented and the challenges and future trends in the development of physical based monitoring techniques for condition assessment of corrosion in reinforced concrete are also put forward.


2015 ◽  
Vol 1124 ◽  
pp. 267-272
Author(s):  
Michal Matysík ◽  
Kristýna Timcakova

The corrosion of steel elements in reinforced concrete can cause considerable damage to civil engineering structures. Early detection of corrosion is therefore very important. Steel in concrete is protected if the concrete pH is higher than 9.6. Carbonated concrete, unfortunately, has a lower pH and this causes that the unprotected steel reinforcement begins to corrode. Nonlinear ultrasonic spectroscopy (NUS) methods shows potential to be very reliable to identify the structure defects in a wide range of materials. These methods are based on the fact that crack-induced nonlinearity makes a sensitive material impairment indicator. This paper describes the ability of one of NUS methods for monitoring steel corrosion in reinforced concrete. It studies nonlinear interaction between elastic waves and structural defects caused by corrosion of steel in concrete. For research we used concrete beams with ten millimetres thick steel rods. These beams were exposed to accelerated degradation by chlorides. The paper presents the initial results of our research.


2008 ◽  
Author(s):  
Jaya Prakash Koduru ◽  
Luke Breon ◽  
Roger Royer ◽  
Joseph L. Rose

2012 ◽  
Vol 12 (1) ◽  
pp. 35-47 ◽  
Author(s):  
Tri H Miller ◽  
Tribikram Kundu ◽  
Jiaqiang Huang ◽  
Julian Y Grill

Sign in / Sign up

Export Citation Format

Share Document