scholarly journals Development of Simple Designs of Multitip Probe Diagnostic Systems for RF Plasma Characterization

2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
M. Y. Naz ◽  
S. Shukrullah ◽  
A. Ghaffar ◽  
N. U. Rehman

Multitip probes are very useful diagnostics for analyzing and controlling the physical phenomena occurring in low temperature discharge plasmas. However, DC biased probes often fail to perform well in processing plasmas. The objective of the work was to deduce simple designs of DC biased multitip probes for parametric study of radio frequency plasmas. For this purpose, symmetric double probe, asymmetric double probe, and symmetric triple probe diagnostic systems and their driving circuits were designed and tested in an inductively coupled plasma (ICP) generated by a 13.56 MHz radio frequency (RF) source. UsingI-Vcharacteristics of these probes, electron temperature, electron number density, and ion saturation current was measured as a function of input power and filling gas pressure. An increasing trend was noticed in electron temperature and electron number density for increasing input RF power whilst a decreasing trend was evident in these parameters when measured against filling gas pressure. In addition, the electron energy probability function (EEPF) was also studied by using an asymmetric double probe. These studies confirmed the non-Maxwellian nature of the EEPF and the presence of two groups of the energetic electrons at low filling gas pressures.

2014 ◽  
Vol 21 (04) ◽  
pp. 1450056 ◽  
Author(s):  
MUHAMMAD YASIN NAZ ◽  
SHAZIA SHUKRULLAH ◽  
ABDUL GHAFFAR ◽  
IMRAN SHAKIR ◽  
SAMI ULLAH ◽  
...  

The electrostatic probes are considered to be the most powerful and experimentally simplest technique for plasma characterization. The objective of the work was to test the nickel-chrome alloy as probe tip material for characterization of RF discharge plasmas. In order to meet the objective, a triple Langmuir probe diagnostic system and associated driving circuit was designed and tested in inductively coupled plasma (ICP) generated by a 13.56 MHz radio frequency (RF) source. Using this probe diagnostic, the electron temperature, electron number density and ion saturation current were measured as a function of input RF power and filling gas pressure. An increasing trend was noticed in electron temperature and electron number density with input power whilst a decreasing trend was evident in these parameters for increasing nitrogen gas pressure. The overall variations in electron temperature and electron number density after repeated measurements were ranging from 5% to 12% and 3% to 13%, respectively.


2021 ◽  
pp. 4694-4701
Author(s):  
Qusay Adnan Abbas

      The present work investigated the effect of distance from target surface on the parameters of lead plasma excited by 1064nm Q-switched Nd:YAG laser. The excitation was conducted in air, at atmospheric pressure, with pulse length of 5 ns, and at different pulse laser energies. Electron temperature was calculated by Boltzmann plot method based on the PbI emission spectral lines (369.03 nm, 416.98 nm, 523.48, and 561.94 nm). The PbI lines were recorded at different distances from the target surface at laser pulse energies of 260 and 280 mJ. The emission intensity of plasma increased with increasing the lens-to-target distance. The results also detected an increase in electron temperature with increasing the distance between the focal lens and the surface of the target in all laser energies under study. In addition, the electron number density was determined by using the Stark broadening method. The data illustrated that the electron number density was increased with increasing the distance from target surface, reaching the maximum at a distance of 11 cm for all pulse laser energy levels under study.


2019 ◽  
Vol 26 (8) ◽  
pp. 083506
Author(s):  
E. C. Dutra ◽  
J. A. Koch ◽  
R. Presura ◽  
P. Wiewior ◽  
A. M. Covington

Sign in / Sign up

Export Citation Format

Share Document