scholarly journals Development of Sensitive and Specific Analysis of Vildagliptin in Pharmaceutical Formulation by Gas Chromatography-Mass Spectrometry

2015 ◽  
Vol 2015 ◽  
pp. 1-7
Author(s):  
Ebru Uçaktürk

A sensitive and selective gas chromatography-mass spectrometry (GC-MS) method was developed and fully validated for the determination of vildagliptin (VIL) in pharmaceutical formulation. Prior to GC-MS analysis, VIL was efficiently derivatized with MSTFA/NH4I/β-mercaptoethanol at 60°C for 30 min. The obtained O-TMS derivative of VIL was detected by selected ion monitoring mode using the diagnostic ionsm/z223 and 252. Nandrolone was chosen as internal standard. The GC-MS method was fully validated by the following validation parameters: limit of detection (LOD) and quantitation (LOQ), linearity, precision, accuracy, specificity, stability, robustness, and ruggedness. LOD and LOQ were found to be 1.5 and 3.5 ng mL−1, respectively. The GC-MS method is linear in the range of 3.5–300 ng mL−1. The intra- and interday precision values were less than ≤3.62%. The intra- and interday accuracy values were found in the range of-0.26–2.06%. Finally, the GC-MS method was successfully applied to determine VIL in pharmaceutical formulation.

1989 ◽  
Vol 72 (2) ◽  
pp. 349-354 ◽  
Author(s):  
Lee Q Huang

Abstract A multiresidue method was developed for the simultaneous determination of low parts per billion (ppb) concentrations of the herbicides alachlor, metolachlor, atrazine, and simazine in water and soil using isotope dilution gas chromatography/mass spectrometry (GC/MS). Known amounts of 15N,13C-alachlor and 2H5-atrazine were added to each sample as internal standards. The samples were then prepared by a solid phase extraction with no further cleanup. A high resolution GC/low resolution MS system with data acquisition in selected ion monitoring mode was used to quantitate herbicides in the extract. The limit of detection was 0.05 ppb for water and 0.5 ppb for soil. Accuracy greater than 80% and precision better than 4% was demonstrated with spiked samples.


Author(s):  
Rosanna Mancini ◽  
Lucia Fernadez-Lopez ◽  
Maria Falcon ◽  
Manuela Pellegrini ◽  
Aurelio Luna ◽  
...  

Abstract A procedure based on gas chromatography-mass spectrometry was developed for the analysis of benzodiazepines (nordiazepam, oxazepam, lormetazepam, lorazepam, clonazepam, bromazepam and alprazolam) in postmortem human ribs. Powdered bone samples, including marrow remains inside, with the internal standard diazepam-d5 were subjected to enzymatic hydrolysis with 100 μL of β-glucoronidase and were incubated in sodium hydroxide for 1 h in a 70°C oven. Samples underwent liquid phase extraction and ethyl acetate was used as eluent. Chromatography was performed on a fused silica capillary column and the selected-ion-monitoring mode was used for analytes determination. The method was validated in the range 0.1–0.5 ng/mg (depending on the benzodiazepine) to 100 ng/mg with average values of recovery, matrix effect and process efficiency ranged from 83.2 to 94.3%, from 97.3 to 102.1% and from 80.5 to 91.2%, respectively. The intra- and inter-day accuracy was <15%. The procedure was tested in rib specimens obtained during routine autopsies from 20 cases where these benzodiazepines were found in blood. Benzodiazepines were detected in the combined bone and marrow samples in 60% of cases. Lorazepam was detected in bone in the range of 0.3–0.7 ng/mg, nordiazepam at 1.3–4.2 ng/mg and oxazepam at 1.1–1.2 ng/mg. To our knowledge, this protocol for the simultaneous analysis of these benzodiazepines is the first performed and validated using human ribs.


1994 ◽  
Vol 77 (4) ◽  
pp. 917-924 ◽  
Author(s):  
Roger T Wilson ◽  
Joseph M Groneck ◽  
Kathleen P Holland ◽  
A Carolyn Henry

Abstract A gas chromatographic/mass spectrometric procedure is described for the quantitation and confirmation of clenbuterol residues from cattle, sheep, and swine tissues. After liquid–liquid extraction and derivatization with phosgene in an aqueous pH 10.1 buffer, the cyclic oxazolidone derivative is quantitated with a clenbuterol analogue as internal standard (NAB-760 CI). Confirmation is accomplished by comparison of ion ratios with those of a pure synthesized standard of clenbuterol oxazolidin-3-one obtained by selected ion monitoring, electron ionization gas chromatography/mass spectrometry on a benchtop instrument. Statistical information based on a series of standard curves for fortified tissues is included to describe method performance. Ion ratio variations were under 15%, and coefficients of variation for spiked tissue standard curves were above 0.997. Recoveries averaged 87.1 ± 6.6% for liver tissues across all 3 species and 67.1 ± 3.8% for muscle tissue across all 3 species.


2019 ◽  
Vol 17 (1) ◽  
pp. 902-911
Author(s):  
Abdulsallam Bakdash

AbstractA gas chromatography-mass spectrometry (GC-MS) method for simultaneous quantification of 3-fluoromethcathinone (3-FMC), (±)-3-fluorophenmetrazine (3-FPM), 4-chloroethcathinone (4-CEC) and 4-Bromomethcathinone (4-BMC) in human blood with (±)-methcathinone-D3 as internal standard has been developed and validated. Whole blood samples were treated with 10% trichloroacetic acid for protein precipitation before solid phase extraction. The method was selective, the calibration curves showed linearity for all substances with R2 ranging from 0.991 to 0.998 in the range 5-1.000 ng/mL. Analysis of blank samples showed no-sign of carryover. Precision and accuracy were acceptable with values less than 20% (RSD) and ± 20% (Bias). The limit of quantification (LOQ) for all substances was 5ng/mL. Intra-day and inter-day precision were 2.111.7% and 1.3 -10.2% respectively and accuracy biases were between -10.6-19.6% % (intra-day) and 11-12.1% (inter-day). The extraction efficiencies were 85.4, 82.8, 79.1 and 74.9% for 3-FMC, 3-FPM, 4-CEC and 4-BMC respectively.A robust and reliable simultaneous quantification method using gas chromatography-mass spectrometry in selected ion monitoring mode (GC-MS-SIM) is reported.


1988 ◽  
Vol 34 (8) ◽  
pp. 1597-1599 ◽  
Author(s):  
D A Herold ◽  
P K Anonick ◽  
M Kinter ◽  
F G Hayden

Abstract Rimantadine is a synthetic antiviral agent used in prophylaxis and in treating the early stages of uncomplicated influenza A illness. We describe a stable isotope-dilution assay involving capillary gas chromatography/mass spectrometry. We used 200 ng of d3-rimantadine, added to 1 mL of plasma, as the internal standard. The rimantadine was extracted from the plasma with a Bond-Elut CN column, the column was washed with water, and the rimantadine was eluted with methanol, dried, and treated to form the t-butyldimethylsilyl derivative. The mass spectrometer was operated in the selected ion monitoring mode. Ions at m/z 236 and m/z 239 were monitored, corresponding to the loss of C4H9 from the rimantadine derivative and d3-rimantadine, respectively. Within-run precision (CVs) ranged from 8.9% at 29 micrograms/L to 3.2% at 1666 micrograms/L. Corresponding data for between-run precision were 5.4% and 1.7%. Treated volunteers (n = 86) provided plasma samples with a concentration range of 153 to 1127 micrograms/L. This simplified method allows rapid, precise assay of rimantadine in plasma.


2016 ◽  
Vol 13 (4) ◽  
pp. 341-347
Author(s):  
Wei Gao ◽  
Naiying Wu ◽  
Wenliang Sun

Purpose This paper aims to present a robust method for the determination of α- and ß-2, 7, 11-cembratriene-4, 6-diols (α, ß-CBT-diol) in tobacco samples which was developed and validated by using the self-made α, ß-CBT-diol with higher purity as the standard. Design/methodology/approach After the ultrasonic extraction and clean-up procedures, samples were analyzed by gas chromatography/mass spectrometry in selected ion monitoring mode and full scan mode at the same time. A 1-heptadecanol was used as an internal standard. The important parameters, such as extraction conditions and derivation conditions, were optimized. Findings Under the optimal conditions, good results in terms of linearity (R2 > 0.999) and recoveries (93.2-107 per cent) were achieved. The limits of detection were 0.120 and 0.180 μg/ml for α- and ß-CBT-diol, respectively. α, ß-CBT-diol level of analyzed tobacco was found in the range of 34.2-1.26 × 103 μg/g with relative standard deviations below 6 per cent. Originality/value Such a strategy opens a new door towards the development of a simple, robust and sensitive method for the determination of α, ß-CBT-diol in real samples.


Author(s):  
Leland B Baskin ◽  
Rodger W Anderson ◽  
Joel R Charlson ◽  
Richard D Hurt ◽  
George M Lawson

A rapid method for measuring nicotine concentration in serum and urine is described. Deuterated nicotine is used as an internal standard. Nicotine and deuterated nicotine are extracted using a copolymeric-bonded phase silica column. The extract is analysed by gas chromatography coupled with mass spectrometry (GC/MS) operating in selected ion monitoring mode. The method has a lower limit of detection of approximately 2 μg/L and is linear to at least 2000 μg/L. Within-run percentage coefficients of variation (% CV) are < 4 in both assays over a nicotine concentration range of 10–2000 μg/L. Between-run %CV in the serum assay are 5.4, 5.2, 4.8 and 5.9, respectively, at nicotine concentrations of 10, 15, 25, and 50 μg/L. Between-run %CV in the urine assay are 5.9, 4.5, 2.7 and 5.2, respectively, at nicotine concentrations of 100, 250, 500, and 2000 μg/L. The absolute recovery of nicotine is 61±+6% (mean±SD) over the range of 10–250 μg/L. The assay has been used to measure serum nicotine concentrations and 24-h urinary excretion of nicotine to monitor the extent of replacement in subjects receiving transdermal nicotine therapy for smoking cessation.


1995 ◽  
Vol 307 (2) ◽  
pp. 331-333 ◽  
Author(s):  
T Kumazawa ◽  
K Sato ◽  
H Seno ◽  
A Ishii ◽  
O Suzuki

The levels of free pyrroloquinoline quinone (PQQ) in various foods were examined by the use of gas chromatography-mass spectrometry. PQQ was extracted from the samples, after addition of [U-13C]PQQ as internal standard, with n-butanol and Sep-Pak C18 cartridges. After derivatization of PQQ with phenyltrimethylammonium hydroxide, molecular peaks at m/z 448 and 462 were used for detection of PQQ and [U-13C]PQQ respectively, by selected ion monitoring. Free PQQ could be detected in every sample in the range 3.7-61 ng/g or ng/ml. Since its levels in human tissues and body fluids are 5-10 times lower than those found in foods, it is probable that PQQ existing in human tissues is derived, at least partly, from the diet.


Sign in / Sign up

Export Citation Format

Share Document