scholarly journals Reliability of the Footscan® Platform System in Healthy Subjects: A Comparison of without Top-Layer and with Top-Layer Protocols

2017 ◽  
Vol 2017 ◽  
pp. 1-9 ◽  
Author(s):  
Chao Xu ◽  
Xin-Xin Wen ◽  
Lu-Yu Huang ◽  
Lei Shang ◽  
Zhao Yang ◽  
...  

The Footscan platform is a useful tool for plantar pressure measurement. However, there is still controversy over whether or not the platform should be covered by top-layer during the test. This study was designed to compare the reliability of the Footscan platform and identify the differences of the foot loading parameters between without top-layer (WOT) and with top-layer (WT) protocols. Measurements were taken from thirty-two healthy subjects. Participants were tested with a Footscan platform using the WOT and WT protocols. Three trials were performed during two separate testing sessions with a 7-day interval. Peak pressure, contact time, contact area, and pressure-time integral at ten foot zones were recorded and calculated for intra- and intersession reliability using intraclass correlation coefficients (ICCs) and coefficients of variation (CVs). The reliability and values of the analyzed parameters for the two protocols were compared. Both protocols produced a moderate to good level of intra- and intersession reliability. Compared with the WT protocol, the WOT protocol showed higher ICCs, lower CVs, and higher values in most of the parameters analyzed. The results suggest that the WOT protocol showed better reliability than the WT protocol. We recommend not using the top-layer when performing the plantar pressure test.

2011 ◽  
Vol 101 (5) ◽  
pp. 424-429
Author(s):  
Keith Rome ◽  
David George Survepalli ◽  
Maria Lobo ◽  
Nicola Dalbeth ◽  
Fiona McQueen ◽  
...  

Background: Plantar pressure measurements are commonly used to evaluate foot function in chronic musculoskeletal conditions. However, manually identifying anatomical landmarks is a source of measurement error and can produce unreliable data. The aim of this study was to evaluate intratester reliability associated with manual masking of plantar pressure measurements in patients with gout. Methods: Twenty-five patients with chronic gout (mean disease duration, 22 years) were recruited from rheumatology outpatient clinics. Patients were excluded if they were experiencing an acute gout flare at the time of assessment, had lower-limb amputation, or had diabetes mellitus. Manual masking of peak plantar pressures and pressure-time integrals under ten regions of the foot were undertaken on two occasions on the same day using an in-shoe pressure measurement system. Test-retest reliability was assessed by using intraclass correlation coefficients, SEM, 95% limits of agreement, and minimal detectable change. Results: Mean peak pressure intraclass correlation coefficients ranged from 0.92 to 0.97, with SEM of 8% to 14%. The 95% limits of agreement ranged from−150.3 to 133.5 kPa, and the minimal detectable change ranged from 30.8 to 80.6 kPa. For pressure-time integrals, intraclass correlation coefficients were 0.86 to 0.94, and SEM were 5% to 29%, with the greater errors observed under the toes. The 95% limits of agreement ranged from −48.5 to 48.8 kPa/sec, and the minimal detectable change ranged from 6.8 to 21.0 kPa/sec. Conclusions: These findings provide clinicians with information confirming the errors associated with manual masking of plantar pressure measurements in patients with gout. (J Am Podiatr Med Assoc 101(5): 424–429, 2011)


2012 ◽  
Vol 36 (2) ◽  
pp. 159-164 ◽  
Author(s):  
Yoon Tae Kim ◽  
Jung Soo Lee

Background: Each plantar pressure measurement system has a different accuracy and reliability, which is required to establish a range of normal values and determine the reliability. Objectives: To determine normal pressures with the Gaitview® system and assess its reliability. Study Design: Single-group repeated measures. Methods: Dynamic barefoot plantar pressure data were obtained in 30 healthy young participants. In each session, three trials were recorded by one examiner for each foot using the two-step gait initiation method, which was repeated by another examiner the same day. One week later, all of the procedures were repeated. Time-integral mean pressures were measured for each of eight anatomical foot regions. The foot contact time (CT) and the time-integral mean angle of the center of pressure (COP) were also measured. Results: The greatest time-integral mean pressures were seen under the medial and lateral heel. The mean CT was 0.9 sec for both feet, and the time-integral mean angle of the COP was 9.3° for the right foot and 6.6° for the left. The intraclass correlation coefficients (ICCs) ranged from 0.69 to 0.97, and the coefficient of variation (CoV) from 9.9 to 59.97% for all parameters. Conclusions: These findings indicate that the Gaitview® system demonstrates good to moderate reliability. Clinical relevance The Gaitview® AFA-50 system (alFOOTs, Seoul, Republic of Korea) has been used by clinicians in Korea, but has not been investigated in an independent study. Therefore, this study established a range of normal values and determined the reliability of the Gaitview® AFA-50 system.


2019 ◽  
Vol 90 (12) ◽  
pp. 1000-1008
Author(s):  
Caleb D. Johnson ◽  
Alice D. LaGoy ◽  
Gert-Jan Pepping ◽  
Shawn R. Eagle ◽  
Anne Z. Beethe ◽  
...  

INTRODUCTION: Designed as a more ecological measure of reaction times, the Perception-Action Coupling Task (PACT) has shown good reliability and within-subject stability. However, a lengthy testing period was required. Perceptual-motor judgments are known to be affected by proximity of the stimulus to the action boundary. The current study sought to determine the effects of action boundary proximity on PACT performance, and whether redundant levels of stimuli, eliciting similar responses, can be eliminated to shorten the PACT.METHODS: There were 9 men and 7 women who completed 4 testing sessions, consisting of 3 familiarization cycles and 6 testing cycles of the PACT. For the PACT, subjects made judgments on whether a series of balls presented on a tablet afford “posting” (can fit) through a series of apertures. There were 8 ratios of ball to aperture size (B-AR) presented, ranging from 0.2 to 1.8, with each ratio appearing 12 times (12 trials) per cycle. Reaction times and judgment accuracy were calculated, and averaged across all B-ARs. Ratios and individual trials within each B-AR were systematically eliminated. Variables were re-averaged, and intraclass correlation coefficients (ICC) and coefficients of variation (CVTE) were calculated in an iterative manner.RESULTS: With elimination of the 0.2 and 1.8 B-ARs, the PACT showed good reliability (ICC = 0.81–0.99) and consistent within-subject stability (CVTE = 2.2–14.7%). Reliability (ICC = 0.81–0.97) and stability (CVTE = 2.6–15.6%) were unaffected with elimination of up to 8 trials from each B-AR.DISCUSSION: The shortened PACT resulted in an almost 50% reduction in total familiarization/testing time required, significantly increasing usability.Johnson CD, LaGoy AD, Pepping G-J, Eagle SR, Beethe AZ, Bower JL, Alfano CA, Simpson RJ, Connaboy C. Action boundary proximity effects on perceptual-motor judgments. Aerosp Med Hum Perform. 2019; 90(12):1000–1008.


1996 ◽  
Vol 80 (1) ◽  
pp. 133-139 ◽  
Author(s):  
M. D. White ◽  
G. Bouchard ◽  
B. Buemann ◽  
N. Almeras ◽  
J. P. Despres ◽  
...  

The maintenance of weight and adipose tissue mass in humans appears to be related to a balance between the rates of oxidation and consumption of macronutrients; yet, little evidence is available on the reproducibility of 24-h macronutrient oxidation rates and how this relates to diet in the days preceding a chamber session. This study examined the reproducibility of 24-h macronutrient oxidation rates, 24-h energy expenditure (EE), and respiratory quotient (RQ) in 30 adults who ate their habitual diets before two 24-h whole body indirect calorimeter sessions. Results showed that the within-subject coefficients of variation (CVws) for 24-h EE and RQ were 2.8 and 2.6%, respectively. CVws for macronutrient oxidations ranged from approximately 15 to 25%. Means comparisons of 24-h EE, RQ, and macronutrient oxidation rates between sessions showed no significant differences, and all variables had significant positive intraclass correlation coefficients (P < 0.05). In conclusion, macronutrient oxidations all showed significant reproducibility for the group and a significant but lower reproducibility for individuals when habitual diet and activity preceded the experimental sessions.


2007 ◽  
Vol 21 (4) ◽  
pp. 474-477 ◽  
Author(s):  
Roberto Castano ◽  
Gilles Thériault ◽  
Denyse Gautrin ◽  
Heberto Ghezzo ◽  
Carole Trudeau ◽  
...  

Background To diagnose occupational rhinitis, it is mandatory to conduct an objective assessment of changes in nasal patency during specific inhalation challenge (SIC). The reproducibility of acoustic rhinometry measurements in the setting of occupational challenges has never been examined. This study assessed the reproducibility of acoustic rhinometry during SIC investigation of occupational rhinitis. Methods Twenty-four subjects underwent acoustic rhinometry measurements during SIC investigation of occupational rhinitis. Subjects attended 3–6 days of SIC within a week by means of a realistic or closed-circuit apparatus methodology Results All of the within-day intraclass correlation coefficients (ICCs) for nasal volume (2–5 cm) and minimum cross-sectional area (MCA) based on a different number of measurements (2–7) were above 0.85; all of the coefficients of variation (CVs) for the same parameters were low (below 10%). The between-day CVs based on different numbers of SIC sessions ranged from 8.0 to 8.8% and from 6.8 to 8.8% for nasal volume and MCA, respectively. The between-day ICCs ranged from 0.80 to 0.88 and from 0.83 to 0.94 for nasal volume and MCA, respectively. Conclusion Acoustic rhinometry showed good within- and between-day reproducibility and can be recommended for the objective monitoring of nasal patency during SIC investigating occupational rhinitis.


2003 ◽  
Vol 93 (5) ◽  
pp. 380-387 ◽  
Author(s):  
Hylton B. Menz ◽  
Anne Tiedemann ◽  
Marcella Mun-San Kwan ◽  
Mark Dominic Latt ◽  
Catherine Sherrington ◽  
...  

Lower-extremity problems are common in older people; however, the reliability of clinical tools used to assess foot and ankle characteristics has not been rigorously evaluated. This study evaluated the test–retest reliability of a battery of simple clinical tests of foot and ankle characteristics (tactile sensitivity of the first metatarsophalangeal joint, navicular height, foot length and width, hallux valgus severity, an overall foot problem score, ankle flexibility, ankle dorsiflexion strength, and foot pain) in 31 individuals (13 men and 18 women) aged 76 to 87 years recruited from the community. Three examiners performed the tests on two occasions approximately 2 weeks apart. Intraclass correlation coefficients and coefficients of variation were calculated for continuously scored tests, and the kappa statistic (κ) was used to determine the reliability of hallux valgus severity grading. All of the continuously scored tests had acceptable reliability (intraclass correlation coefficients of 0.64 to 0.98; coefficients of variation of 0.6% to 15.0%), as did hallux valgus severity grading (κ = 0.77; absolute percentage agreement, 84%). These simple clinical tests can now be used with confidence in clinical and research settings to provide reliable and functionally important information regarding foot and ankle characteristics in older people. (J Am Podiatr Med Assoc 93(5): 380-387, 2003)


2019 ◽  
Author(s):  
Nathan E. Hall ◽  
Jared Mamrot ◽  
Christopher M.A. Frampton ◽  
Prue Read ◽  
Edward J. Steele ◽  
...  

AbstractBackgroundDeaminases play an important role in shaping inherited and somatic variants. Disease related SNVs are associated with deaminase mutagenesis and genome instability. Here, we investigate the reproducibility and variance of whole exome SNV calls in blood and saliva of healthy subjects and analyze variants associated with AID, ADAR, APOBEC3G and APOBEC3B deaminase sequence motifs.MethodsSamples from twenty-four healthy Caucasian volunteers, allocated into two groups, underwent whole exome sequencing. Group 1 (n=12) analysis involved one blood and four saliva replicates. A single saliva sample was sequenced for Group 2 subjects (n=12). Overall, a total of 72 whole exome datasets were analyzed. Biological (Group 1 & 2) and technical (Group 1) variance of SNV calls and deaminase metrics were calculated and analyzed using intraclass correlation coefficients. Candidate somatic SNVs were identified and evaluated.ResultsWe report high blood-saliva concordance in germline SNVs from whole exome sequencing. Concordant SNVs, found in all subject replicates, accounted for 97% of SNVs located within the protein coding sequence of genes. Discordant SNVs have a 30% overlap with variants that fail gnomAD quality filters and are less likely to be found in dbSNP. SNV calls and deaminase-associated metrics were found to be reproducible and robust (intraclass correlation coefficients >0.95). No somatic SNVs were conclusively identified when comparing blood and saliva samples.ConclusionsSaliva and blood both provide high quality sources of DNA for whole exome sequencing, with no difference in ability to resolve SNVs and deaminase-associated metrics. We did not identify somatic SNVs when comparing blood and saliva of healthy individuals, and we conclude that more specialized investigative methods are required to comprehensively assess the impact of deaminase activity on genome stability in healthy individuals.


Author(s):  
Megan Sax van der Weyden ◽  
Christopher D. Black ◽  
Daniel Larson ◽  
Brian Rollberg ◽  
Jason A. Campbell

This investigation examined relationships between a Special Weapons and Tactics-specific fitness test (SORT) and an obstacle course (OC) used for qualification in fourteen male SWAT members from three local, regional police departments. The SORT included: squat, pushup, and lunge in 60 s; pullup hold; sled drag; and Yo-Yo Intermittent Recovery Test L1. The obstacle course included: 25 m sprint (repeated); window ascent; scale under a wall; 25 m serpentine run (repeated), body drag (20 m, repeated). Pearson coefficients examined SORT and OC relationships (p ≤ 0.05); intraclass correlation coefficients (ICC2,1) assessed agreement of SORT trials. Repeated measures ANOVA evaluated differences in SORT metrics across time. Coefficients of variation (COV) examined SORT scoring consistency. The YoYo test was related to all SORT assessments (r = −0.803–0.894), except sled drag. The remaining SORT metrics were related to ≥two tests. SORT COVs ranged from 0.77–13.26% for trials 1–2 but decreased between trials 2–3 (0.95–8.97%). The OC was associated with YoYo, lunges, squats and sled drag (r = −0.790, −0.730, −0.766, and 0.802, respectively). No differences (p > 0.05) existed across SORT trials for event scores. The SORT battery appears to be a valid and reliable testing measure to assess SWAT occupational specific fitness.


Author(s):  
Omolbanin Abaspour ◽  
Mohammad Akbari ◽  
Asghar Rezasoltani

Introduction: In Cervicogenic Headache (CGH), motor control of muscles is impaired and deep upper neck muscles (extensor and flexor muscles) become atrophied. In this research, thickness measurement of Longus Capitis (LCap), Rectus Capitis Posterior Major (RCPM), and Obliquus Capitis Superior (OCS) muscles were conducted and intra-rater reliability of the thickness measurement of these muscles was assessed in CGH and healthy subjects. Materials and Methods: Twenty subjects, including 10 healthy subjects (19-32 years old) and 10 CGH patients (20-35 years old) participated in this study. LCap thickness was measured at the level of C3-C4 in the supine position and posterior muscles (RCPM and OCS) thickness at the C1-C2 level in the sitting position. All ultrasound images were captured by a linear probe with a 50-mm footprint in B mode option and frequency range of 9-12 Hz. Intraclass Correlation Coefficients (ICC), Standard Error Of Measurement (SEM), and the Smallest Detectable Difference (SDD) were calculated for data analysis. Results: The ICC for thickness measurement of LCap was from 0.70 to 0.91 (good to excellent), for RCPM thickness was from 0.69 to 0.94 and for OCS muscle thickness was from 0.87 to 0.98. SEM values for LCap were between 0.08 and 0.25 and the SDD values between 0.22 and 0.71. SEM values for RCPM were between 0.22 and 0.43 and these values were reported for OCS muscle between 0.19 and 0.45. Conclusion: The results indicated that the presented position and the level of ultrasonography in this study are appropriate and ultrasound is a reliable tool to measure the deep upper neck muscle thickness in CGH and healthy subjects.


2020 ◽  
Vol 33 (6) ◽  
pp. 783-791
Author(s):  
Yusuke Yokota ◽  
Tomohisa Okada ◽  
Yasutaka Fushimi ◽  
Akira Yamamoto ◽  
Satoshi Nakajima ◽  
...  

Abstract Objective To compare the absolute values and repeatability of magnetic resonance fingerprinting (MRF) with 3000 and 1500 echoes/slice acquired in 41 s and 20 s (MRF3k and MRF1.5k, respectively). Materials and methods MRF3k and MRF1.5k scans based on fast imaging with steady precession (FISP) were conducted using a 3 T scanner. Inter-scan agreement and intra-scan repeatability were investigated in 41 and 28 subjects, respectively. Region-of-interest (ROI) analysis was conducted on T1 values of MRF3k by two raters, and their agreement was evaluated using intraclass correlation coefficients (ICCs). Between MRF3k and MRF1.5k, differences in T1 and T2 values and inter-measurement correlation coefficients (CCs) were investigated. Intra-measurement repeatability was evaluated using coefficients of variation (CVs). A p value < 0.05 was considered statistically significant. Results The ICCs of ROI measurements were 0.77–0.96. Differences were observed between the two MRF scans, but the CCs of the overall ROIs were 0.99 and 0.97 for the T1 and T2 values, respectively. The mean and median CVs of repeatability were equal to or less than 1.58% and 3.13% in each of the ROIs for T1 and T2, respectively; there were some significant differences between MRF3k and MRF1.5k, but they were small, measuring less than 1%. Discussion Both MRF3k and MRF1.5k had high repeatability, and a strong to very strong correlation was observed, with a trend toward slightly higher values in MRF1.5k.