scholarly journals Effects of the Insertion Type and Depth on the Pedicle Screw Pullout Strength: A Finite Element Study

2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
K. Jendoubi ◽  
Y. Khadri ◽  
M. Bendjaballah ◽  
N. Slimane

Purpose. The pedicle screw is a surgical device that has become widely used in spinal fixation and stabilization. Postsurgical complications such as screw loosening due to fatigue loading and screw breakage still need investigations. Clinical parameters such as the screw insertion type and depth, the bone density, and the patient degree of mobility greatly affect the mechanisms of the implant’s failure/success. Methods. The current finite element study focused on the prediction of the pedicle screw pullout strength under various conditions such as insertion type, insertion depth, bone quality, and loading mode. Results. As depicted in this study, the preservation of the pedicle cortex as in the N1 insertion technique greatly enhances the pullout resistance. In addition, the higher the screw-anchoring depth, permitting to gear a maximum number of threads, the better the protection against premature breakouts of pedicle screws. Conclusions. In agreement with experimental data, the type of insertion in which the first screw thread is placed immediately after the preserved pedicle cortex showed the best pullout resistance for both normal and osteoporotic bone.

2020 ◽  
Vol 25 (1) ◽  
pp. 66-72 ◽  
Author(s):  
Shota Takenaka ◽  
Takashi Kaito ◽  
Ken Ishii ◽  
Kota Watanabe ◽  
Kei Watanabe ◽  
...  

2015 ◽  
Vol 2015 ◽  
pp. 1-11 ◽  
Author(s):  
Thomas M. Shea ◽  
James J. Doulgeris ◽  
Sabrina A. Gonzalez-Blohm ◽  
William E. Lee ◽  
Kamran Aghayev ◽  
...  

Many successful attempts to increase pullout strength of pedicle screws in osteoporotic bone have been accompanied with an increased risk of catastrophic damage to the patient. To avoid this, a single-armed expansive pedicle screw was designed to increase fixation strength while controlling postfailure damage away from the nerves surrounding the pedicle. The screw was then subsequently tested in two severely osteoporotic models: one representing trabecular bone (with and without the presence of polymethylmethacrylate) and the other representing a combination of trabecular and cortical bone. Maximum pullout strength, stiffness, energy to failure, energy to removal, and size of the resulting block damage were statistically compared among conditions. While expandable pedicle screws produced maximum pullout forces less than or comparable to standard screws, they required a higher amount of energy to be fully removed from both models. Furthermore, damage to the cortical layer in the composite test blocks was smaller in all measured directions for tests involving expandable pedicle screws than those involving standard pedicle screws. This indicates that while initial fixation may not differ in the presence of cortical bone, the expandable pedicle screw offers an increased level of postfailure stability and safety to patients awaiting revision surgery.


Sign in / Sign up

Export Citation Format

Share Document