scholarly journals Femtosecond Laser-Assisted In Situ Keratomileusis Treatment of Residual Refractive Error following Femtosecond Laser-Enabled Keratoplasty

2019 ◽  
Vol 2019 ◽  
pp. 1-6
Author(s):  
Elizabeth Shen ◽  
Lester Tsai ◽  
Hannah Muniz Castro ◽  
Matthew Wade ◽  
Marjan Farid

Purpose. To evaluate the safety and effectiveness of femtosecond laser-assisted in situ keratomileusis (LASIK) in the treatment of residual myopia and astigmatism following femtosecond laser-enabled keratoplasty (FLEK). Design. Retrospective case review. Methods. Chart review of all patients with prior FLEK who subsequently underwent femto-LASIK surgery after full suture removal was performed at the Gavin Herbert Eye Institute at the University of California, Irvine. A total of 14 eyes in 13 patients met this criterion, and their comprehensive examinations performed at standard intervals were reviewed. Main outcome measures include uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) expressed as the logarithm of the minimum angle of resolution (logMAR), manifest refractive astigmatism, and spherical equivalent. Results. From the preoperative visit to the 3 month visit, all 14 eyes significantly improved in UDVA (logMAR, 0.93 ± 0.23 to 0.44 ± 0.32, P=0.002) with no loss of CDVA (logMAR, 0.26 ± 0.19 to 0.18 ± 0.23, P=0.50). All 14 eyes showed significant improvement in manifest refractive astigmatism (4.71 ± 1.77 to 2.18 ± 1.45 diopters (D), P=0.003) and spherical equivalent (−2.57 ± 2.45 to −0.48 ± 0.83 D, P=0.0007). There were no flap or graft complications as a result of femto-LASIK. Conclusions. Our findings suggest that femto-LASIK on eyes with prior FLEK is safe and effective in improving visual acuity and reducing residual astigmatism.

2019 ◽  
Vol 30 (6) ◽  
pp. 1246-1255 ◽  
Author(s):  
Tiago Monteiro ◽  
José F Alfonso ◽  
Nuno Franqueira ◽  
Fernando Faria-Correira ◽  
Renato Ambrósio ◽  
...  

Purpose: The purpose was to compare the visual, refractive and aberrometric results of intrastromal corneal ring segments implantation with manual dissection and femtosecond laser–assisted surgery. Methods: This is a multicentre study, which included consecutive patients with paracentral keratoconus, in which the difference between the axes of the topographic flattest and the coma aberration was <60°, who had Ferrara-type intrastromal corneal ring segment implantation using manual dissection or femtosecond laser technique. LogMAR uncorrected (uncorrected distance visual acuity) and corrected (corrected distance visual acuity) distance visual acuity, refractive errors and the root mean square for corneal coma-like aberration were recorded before and at 6 months after surgery. Results: The study included 84 and 110 eyes in the manual group and in the femtosecond group, respectively. After surgery, there was a statistically significant improvement in uncorrected distance visual acuity and corrected distance visual acuity for both groups ( p < 0.0001), and there were no statistically significant differences between groups ( p > 0.3). For both groups, there was a reduction in spherical equivalent after intrastromal corneal ring segment implantation ( p < 0.0001). There were no statistically significant differences between groups in the magnitude of spherical equivalent reduction ( p = 0.34) The magnitude of the root mean square coma-like reduction was 0.93 ± 0.76 and 0.83 ± 0.80 μm in the manual and femtosecond group, respectively ( p = 0.2). While in the femtosecond laser group no complications were reported, in the manual group, the intraoperative or postoperative complications rate was 13.09%. Conclusion: Although both surgical techniques provide comparable visual, refractive and aberrometric outcomes, it should be noted that the femtosecond laser is a safer surgical procedure, with no complications reported.


2018 ◽  
Vol 30 (1) ◽  
pp. 139-146 ◽  
Author(s):  
Guilherme Andrade do Nascimento Rocha ◽  
Paulo Ferrara de Almeida Cunha ◽  
Leonardo Torquetti Costa ◽  
Luciene Barbosa de Sousa

Importance: This study shows that a newer long-arc length intrastromal corneal ring segment is efficient and safe for keratoconus treatment. Background: To evaluate visual, tomographic results and complications of a 320-degree intrastromal corneal ring segment implantation with the femtosecond laser for keratoconus treatment. Design: A prospective, nonrandomized, and interventional study. Participants: A total of 34 eyes of 31 patients diagnosed with keratoconus were enrolled. Methods: Patients were divided into two groups based on the strategy used for 320-degree intrastromal corneal ring segment thickness selection. In one group, this selection was based on spherical equivalent (SE group) and in the other on the mean asphericity (Q group). The uncorrected and corrected distance visual acuities, spherical equivalent, K1, K2, Km, Kmax, and mean asphericity ( Q) on corneal tomography were evaluated preoperatively and at 3 and 6 months postoperatively. For astigmatism improvement, we analyzed the corneal tomographic vectorial astigmatism change preoperatively and at 6 months postoperatively. The mean follow-up period was 6.63 ± 0.96 months. Results: The mean uncorrected distance visual acuity and corrected distance visual acuity improved with a significant spherical equivalent improvement ( p < 0.05), with no differences between the 320-degree intrastromal corneal ring segment groups. All corneal tomographic parameters improved significantly ( p < 0.05) between the preoperative and postoperative intervals, with a significant better performance when we used spherical equivalent for the 320-degree intrastromal corneal ring segment thickness selection. Finally, the mean vectorial corneal tomographic astigmatism significantly improved after 6 months, again with no differences between groups. Conclusion: This study suggests that implanting a 320-degree intrastromal corneal ring segment is a safe and effective procedure for treating patients with keratoconus. It also suggests that for thickness selection spherical equivalent is the better strategy.


2019 ◽  
Vol 30 (6) ◽  
pp. 1278-1286 ◽  
Author(s):  
Suphi Taneri ◽  
Saskia Kießler ◽  
Anika Rost ◽  
Tim Schultz ◽  
H Burkhard Dick

Purpose: To compare the visual and refractive outcomes of small incision lenticule extraction and advanced surface ablation for low myopia or myopic astigmatism. Methods: Retrospective, observational case series of our first 50 consecutive small incision lenticule extraction patients compared to refraction-matched 50 advanced surface ablation treatments with attempted spherical equivalent correction ⩽−3.5 D, astigmatism ⩽−1.5 D, and corrected distance visual acuity of 1.0 (decimal scale) or better. Only one eye per patient was included. Results: Small incision lenticule extraction: mean attempted spherical equivalent correction was −2.80 ± 0.63 D. Uncorrected distance visual acuity was 0.85 and 1.0 at days 1 and 5, respectively. At 3 months, mean spherical equivalent refraction was 0.02 ± 0.32 D (range: −0.5 to +0.75 D), mean cylinder was −0.24 ± 0.21 D (range: 0 to −0.75 D), mean uncorrected distance visual acuity was 1.27, mean efficacy index was 0.96, and mean safety index was 1.05. Uncorrected distance visual acuity was same or better than corrected distance visual acuity in 96%, astigmatism ⩽0.5 D in 98% and ⩽1 D in 100% of eyes, respectively. Advanced surface ablation: mean attempted spherical equivalent correction was −2.75 ± 0.5 D. Uncorrected distance visual acuity was 0.72 and 0.61 at days 1 and 5, respectively. At 3 months, mean spherical equivalent refraction was 0.22 ± 0.32 D, mean cylinder was −0.27 ± 0.27 D, mean uncorrected distance visual acuity was 1.21, mean efficacy index was 1.03, and mean safety index was 1.08. Conclusion: Small incision lenticule extraction for low myopia was found to be safe and effective with outcomes at 3 months similar to those obtained with advanced surface ablation while offering a quicker visual recovery.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Jaeryung Kim ◽  
Sung-Ho Choi ◽  
Dong Hui Lim ◽  
Gil-Joong Yoon ◽  
Tae-Young Chung

Abstract Background To compare the outcomes of myopia and myopic astigmatism corrected with topography-modified refraction laser in situ keratomileusis (TMR-LASIK), wavefront-optimized (WFO) LASIK, and topography-guided (TG) LASIK with a correction target based on the manifest refraction (manifest TG-LASIK). Methods This observational, retrospective cohort study included patients who underwent LASIK using the WaveLight® EX500 excimer laser to correct myopia and myopic astigmatism between August 2016 and July 2017. Patients who underwent TMR-LASIK (85 patients), WFO-LASIK (70 patients), or manifest TG-LASIK (40 patients) were enrolled, and only one eye from each patient was analyzed. All participants underwent measurement of the uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA), manifest refraction, vector analysis of astigmatic change, corneal topography, and corneal wavefront analysis at baseline and at every posttreatment visit. Results Three months postoperatively, a UDVA of 0.0 logMAR or better and manifest refraction spherical equivalent (MRSE) within ±0.5 diopters (D) did not differ across the TMR-, WFO-, and manifest TG-LASIK groups. However, the residual cylinder in the TMR group was significantly larger than that in the WFO and manifest TG groups. The magnitude of error in the TMR group measured using astigmatism vector analysis was significantly higher than that in the WFO and manifest TG groups. Conclusions Although these three LASIK platforms achieved the predicted surgical outcomes, TMR-LASIK overcorrected astigmatism and showed a higher residual postoperative astigmatism compared with WFO- and manifest TG-LASIK.


2021 ◽  
Vol 25 (6) ◽  
pp. 1-68
Author(s):  
Alexander C Day ◽  
Jennifer M Burr ◽  
Kate Bennett ◽  
Rachael Hunter ◽  
Catey Bunce ◽  
...  

Background Cataract surgery is one of the most common operations. Femtosecond laser-assisted cataract surgery (FLACS) is a technique that automates a number of operative steps. Objectives To compare FLACS with phacoemulsification cataract surgery (PCS). Design Multicentre, outcome-masked, randomised controlled non-inferiority trial. Setting Three collaborating NHS hospitals. Participants A total of 785 patients with age-related cataract in one or both eyes were randomised between May 2015 and September 2017. Intervention FLACS (n = 392 participants) or PCS (n = 393 participants). Main outcome measures The primary outcome was uncorrected distance visual acuity in the study eye after 3 months, expressed as the logarithm of the minimum angle of resolution (logMAR): 0.00 logMAR (or 6/6 if expressed in Snellen) is normal (good visual acuity). Secondary outcomes included corrected distance visual acuity, refractive outcomes (within 0.5 dioptre and 1.0 dioptre of target), safety and patient-reported outcome measures at 3 and 12 months, and resource use. All trial follow-ups were performed by optometrists who were masked to the trial intervention. Results A total of 353 (90%) participants allocated to the FLACS arm and 317 (81%) participants allocated to the PCS arm attended follow-up at 3 months. The mean uncorrected distance visual acuity was similar in both treatment arms [0.13 logMAR, standard deviation 0.23 logMAR, for FLACS, vs. 0.14 logMAR, standard deviation 0.27 logMAR, for PCS, with a difference of –0.01 logMAR (95% confidence interval –0.05 to 0.03 logMAR; p = 0.63)]. The mean corrected distance visual acuity values were again similar in both treatment arms (–0.01 logMAR, standard deviation 0.19 logMAR FLACS vs. 0.01 logMAR, standard deviation 0.21 logMAR PCS; p = 0.34). There were two posterior capsule tears in the PCS arm. There were no significant differences between the treatment arms for any secondary outcome at 3 months. At 12 months, the mean uncorrected distance visual acuity was 0.14 logMAR (standard deviation 0.22 logMAR) for FLACS and 0.17 logMAR (standard deviation 0.25 logMAR) for PCS, with a difference between the treatment arms of –0.03 logMAR (95% confidence interval –0.06 to 0.01 logMAR; p = 0.17). The mean corrected distance visual acuity was 0.003 logMAR (standard deviation 0.18 logMAR) for FLACS and 0.03 logMAR (standard deviation 0.23 logMAR) for PCS, with a difference of –0.03 logMAR (95% confidence interval –0.06 to 0.01 logMAR; p = 0.11). There were no significant differences between the arms for any other outcomes, with the exception of the mean binocular corrected distance visual acuity with a difference of –0.02 logMAR (95% confidence interval –0.05 to 0.00 logMAR) (p = 0.036), which favoured FLACS. There were no significant differences between the arms for any health, social care or societal costs. For the economic evaluation, the mean cost difference was £167.62 per patient higher for FLACS (95% of iterations between –£14.12 and £341.67) than for PCS. The mean QALY difference (FLACS minus PCS) was 0.001 (95% of iterations between –0.011 and 0.015), which equates to an incremental cost-effectiveness ratio (cost difference divided by QALY difference) of £167,620. Limitations Although the measurement of outcomes was carried out by optometrists who were masked to the treatment arm, the participants were not masked. Conclusions The evidence suggests that FLACS is not inferior to PCS in terms of vision after 3 months’ follow-up, and there were no significant differences in patient-reported health and safety outcomes after 12 months’ follow-up. In addition, the statistically significant difference in binocular corrected distance visual acuity was not clinically significant. FLACS is not cost-effective. Future work To explore the possible differences in vision in patients without ocular co-pathology. Trial registration Current Controlled Trials ISRCTN77602616. Funding This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 25, No. 6. See the NIHR Journals Library website for further project information. Moorfields Eye Charity (grant references GR000233 and GR000449 for the endothelial cell counter and femtosecond laser used).


2021 ◽  
Vol 10 (17) ◽  
pp. 3776
Author(s):  
Majid Moshirfar ◽  
Rachel Huynh ◽  
Nour Bundogji ◽  
Alyson N. Tukan ◽  
Thomas M. Sant ◽  
...  

Previous studies have demonstrated safety and efficacy using 6.0 and 6.5 mm optical zones in the WaveLight EX500 Excimer Laser System but have not evaluated if differing optical zone sizes influence refractive outcomes. This study examines visual outcomes between two study populations undergoing LASIK with either a 6.0 mm (1332 patients) or 6.5 mm (1332 patients) optical zone. Outcomes were further stratified by severity of myopia (low, moderate, and high) and astigmatism (low and high). Patients were matched by age and preoperative manifest sphere and cylinder. Postoperative measurements were then compared. The 6.5 mm group demonstrated better postoperative manifest refractive spherical equivalent (MRSE), manifest sphere, and absolute value of the difference in actual and target spherical equivalent refraction (|∆ SEQ|), within the total population, moderate myopia, and low astigmatism groups, but this did not lead to improved postoperative uncorrected distance visual acuity (UDVA) or best corrected distance visual acuity (CDVA). Though astigmatic correction and postoperative angle of error were similar between optical zone sizes, they were significantly worse with high myopia. Overall, this study demonstrates differences in visual outcomes between the 6.0 and 6.5 mm optical zone sizes that may warrant consideration; however, essentially, the results are comparable between them.


2019 ◽  
Vol 30 (4) ◽  
pp. 643-649 ◽  
Author(s):  
Luis Fernández-Vega-Cueto ◽  
Carlos Lisa ◽  
Aranzazu Poo-López ◽  
José F Alfonso ◽  
David Madrid-Costa

Purpose: To assess the outcomes of implanting Ferrara-type intrastromal corneal ring segments in central ‘bow-tie’-shaped keratoconus over 3 years of follow-up. Methods: A total of 20 eyes with central ‘bow-tie’-shaped keratoconus were evaluated before and after implanting Ferrara-type intrastromal corneal ring segments (AJL Ophthalmic, Spain). LogMAR uncorrected distance visual acuity and best corrected distance visual acuity and residual refractive errors analysed using vector analysis were recorded preoperatively, at 6 months, 1 year, and 3 years postoperatively. Results: The mean uncorrected distance visual acuity (LogMAR scale) rose from a preoperative 0.75 ± 0.28 to a 6-month postoperative 0.38 ± 0.28 (p < 0.0001). The corrected distance visual acuity, in turn, improved from 0.07 ± 0.06 to 0.05 ± 0.06 (p = 0.0008). Both the uncorrected distance visual acuity and corrected distance visual acuity were stable over the postoperative period in both groups (p > 0.05). None of the eyes lost uncorrected distance visual acuity and corrected distance visual acuity lines over the postoperative follow-up period. The spherical equivalent and the refractive cylinder declined steeply after intrastromal corneal ring segments implantation (p < 0.0001). Both the spherical equivalent and refractive cylinder were stable over the postoperative period. None of the eyes had an increase in maximum or minimum keratometry greater than 0.75D over the postoperative period. Conclusion: The planning for intrastromal corneal ring segments insertion proposed in this study reduces the spherical equivalent and refractive cylinder in this type of keratoconus, while improving post-surgery uncorrected distance visual acuity and corrected distance visual acuity. These results remain stable over 3 years of follow-up. Therefore, this procedure could be considered as an effective therapeutic alternative in patients affected by this type of keratoconus.


2020 ◽  
Author(s):  
JUNJIE PIAO ◽  
Woong-Joo Whang ◽  
Choun-Ki Joo

Abstract Background This study clinically evaluated the visual outcomes after refractive surgery for myopia using femtosecond laser-assisted in situ keratomileusis (femto-LASIK) and epi-LASIK (flap-off). Methods In this prospective cohort study, 40 eyes of 27 patients were divided into two groups depending on the technique used for refractive surgery. Femto-LASIK flaps and epi-LASIK flaps (flap-off) were created using femtosecond laser and Epi-K TM epikeratome, respectively. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction (MR), corneal asphericity (Q-value), and corneal higher-order aberrations (HOAs) were assessed pre- and postoperatively. Results The improvement in LogMAR UDVA after refractive surgery was statistically significant for both groups ( P < 0.001 for all groups); it was significantly improved in the femto-LASIK group, 1 day and 1 week postoperatively ( P < 0.001, P = 0.019, respectively). With regard to the front and total corneal HOAs, there were significant differences in spherical aberrations (Z 4,0 ) between the femto-LASIK and flap-off epi-LASIK groups ( P = 0.016 and P = 0.017, respectively). With regard to the back corneal HOAs, there were significant differences in vertical coma (Z 3,-1 ) aberration, 0.027 ± 0.027 μm (femto-LASIK) and 0.001 ± 0.034 μm (flap-off epipolis LASIK); horizontal secondary astigmatism (Z 4,2 ) aberration, -0.008 ± 0.012 μm (femto-LASIK) and 0.007 ± 0.018 μm (flap-off epipolis LASIK); oblique tetrafoil (Z 4,-4 ) aberration, -0.008 ± 0.029 μm (femto-LASIK) and 0.015 ± 0.026 μm (flap-off epi-LASIK), respectively ( P = 0.018, P = 0.007, and P = 0.022, respectively). However, the back corneal HOA changes did not have a significant effect on the total corneal HOA changes. Conclusion Femto-LASIK yielded better early visual outcomes than did flap-off epi-LASIK, but there was no significant difference between the outcomes of the two procedures, 1 week postoperatively.


2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Jing Wang ◽  
Weiqian Cao ◽  
Liming Tao

Purpose. To assess the efficacy and safety of transepithelial photorefractive keratectomy (TPRK) without mitomycin C as treatment for femtosecond laser in situ keratomileusis (FS-LASIK) corneal flap complications. Methods. Eight patients with corneal flap complications that occurred after FS-LASIK (five with eccentric flaps, two with buttonhole flaps, and one with a thick flap) were included in the study. Patients were treated with TPRK without mitomycin C between two weeks and twelve months after surgery. The postoperative manifest refraction, uncorrected distance visual acuity, and haze formation were assessed during six months of follow-up. Results. The mean manifest refractive spherical and cylinder refraction was 0.16 ± 0.26 and −0.44 ± 0.33 diopters, respectively, at six months postoperatively. The uncorrected distance visual acuity was above 20/25 in all patients after six months of follow-up. No haze formation was detected. Conclusions. TPRK without mitomycin C appears to be a safe and effective treatment for FS-LASIK corneal flap complications.


2020 ◽  
Author(s):  
Fang Liu ◽  
Ting Zhang ◽  
Quan Liu

Abstract Background: To investigate the long-term safety and efficacy of aspheric micro-monovision LASIK for the correction of presbyopia and myopic astigmatism. Methods: In total, 114 eyes of 57 patients with a mean age of 48 ± 4.05 years (range: 43 to 62 years) who were undergoing aspheric micro-monovision LASIK treatment were enrolled. Visual acuity, manifest refraction, amplitude of accommodation, contrast sensitivity, entire eye aberrations and patients’ subjective ratings were evaluated from 1 day to 3 years postoperatively. Results: None of the eyes showed a spherical equivalent change of over 0.75 D between 3 months and 3 years, while 95% of the eyes were within ±0.50 D of the target correction of the spherical equivalent. The percentage of patients showing monocular uncorrected distance visual acuity ≥20/20 was 95%, and all eyes achieved a visual acuity of 20/25 or better. The percentage of patients showing binocular uncorrected near visual acuity ≥J2 was 93%, and all patients achieved a visual acuity of J4 or better. Ninety-one percent of the patients had an uncorrected visual acuity of 20/20 in both eyes and J2 or better binocular visual acuity. Six of 108 eyes (6%) lost 1 line, and no eyes lost 2 lines of corrected distance visual acuity. The overall satisfaction score for surgery was 93 ± 6. Conclusions: Aspheric micro-monovision LASIK using the Carl Zeiss Meditec MEL 80 Platform was an efficacious option for older myopic patients with presbyopia. Three-year postoperative outcomes in the Chinese population indicated improvements in uncorrected binocular vision at far and near distances with high satisfaction. Trial registration: The registration number is ChiCTR-IPC-15005842, and the date of registration is January 16, 2015.