Outcomes of a 320-degree intrastromal corneal ring segment implantation for keratoconus: Results of a 6-month follow-up

2018 ◽  
Vol 30 (1) ◽  
pp. 139-146 ◽  
Author(s):  
Guilherme Andrade do Nascimento Rocha ◽  
Paulo Ferrara de Almeida Cunha ◽  
Leonardo Torquetti Costa ◽  
Luciene Barbosa de Sousa

Importance: This study shows that a newer long-arc length intrastromal corneal ring segment is efficient and safe for keratoconus treatment. Background: To evaluate visual, tomographic results and complications of a 320-degree intrastromal corneal ring segment implantation with the femtosecond laser for keratoconus treatment. Design: A prospective, nonrandomized, and interventional study. Participants: A total of 34 eyes of 31 patients diagnosed with keratoconus were enrolled. Methods: Patients were divided into two groups based on the strategy used for 320-degree intrastromal corneal ring segment thickness selection. In one group, this selection was based on spherical equivalent (SE group) and in the other on the mean asphericity (Q group). The uncorrected and corrected distance visual acuities, spherical equivalent, K1, K2, Km, Kmax, and mean asphericity ( Q) on corneal tomography were evaluated preoperatively and at 3 and 6 months postoperatively. For astigmatism improvement, we analyzed the corneal tomographic vectorial astigmatism change preoperatively and at 6 months postoperatively. The mean follow-up period was 6.63 ± 0.96 months. Results: The mean uncorrected distance visual acuity and corrected distance visual acuity improved with a significant spherical equivalent improvement ( p < 0.05), with no differences between the 320-degree intrastromal corneal ring segment groups. All corneal tomographic parameters improved significantly ( p < 0.05) between the preoperative and postoperative intervals, with a significant better performance when we used spherical equivalent for the 320-degree intrastromal corneal ring segment thickness selection. Finally, the mean vectorial corneal tomographic astigmatism significantly improved after 6 months, again with no differences between groups. Conclusion: This study suggests that implanting a 320-degree intrastromal corneal ring segment is a safe and effective procedure for treating patients with keratoconus. It also suggests that for thickness selection spherical equivalent is the better strategy.

2019 ◽  
Vol 30 (4) ◽  
pp. 643-649 ◽  
Author(s):  
Luis Fernández-Vega-Cueto ◽  
Carlos Lisa ◽  
Aranzazu Poo-López ◽  
José F Alfonso ◽  
David Madrid-Costa

Purpose: To assess the outcomes of implanting Ferrara-type intrastromal corneal ring segments in central ‘bow-tie’-shaped keratoconus over 3 years of follow-up. Methods: A total of 20 eyes with central ‘bow-tie’-shaped keratoconus were evaluated before and after implanting Ferrara-type intrastromal corneal ring segments (AJL Ophthalmic, Spain). LogMAR uncorrected distance visual acuity and best corrected distance visual acuity and residual refractive errors analysed using vector analysis were recorded preoperatively, at 6 months, 1 year, and 3 years postoperatively. Results: The mean uncorrected distance visual acuity (LogMAR scale) rose from a preoperative 0.75 ± 0.28 to a 6-month postoperative 0.38 ± 0.28 (p < 0.0001). The corrected distance visual acuity, in turn, improved from 0.07 ± 0.06 to 0.05 ± 0.06 (p = 0.0008). Both the uncorrected distance visual acuity and corrected distance visual acuity were stable over the postoperative period in both groups (p > 0.05). None of the eyes lost uncorrected distance visual acuity and corrected distance visual acuity lines over the postoperative follow-up period. The spherical equivalent and the refractive cylinder declined steeply after intrastromal corneal ring segments implantation (p < 0.0001). Both the spherical equivalent and refractive cylinder were stable over the postoperative period. None of the eyes had an increase in maximum or minimum keratometry greater than 0.75D over the postoperative period. Conclusion: The planning for intrastromal corneal ring segments insertion proposed in this study reduces the spherical equivalent and refractive cylinder in this type of keratoconus, while improving post-surgery uncorrected distance visual acuity and corrected distance visual acuity. These results remain stable over 3 years of follow-up. Therefore, this procedure could be considered as an effective therapeutic alternative in patients affected by this type of keratoconus.


2019 ◽  
Vol 30 (6) ◽  
pp. 1246-1255 ◽  
Author(s):  
Tiago Monteiro ◽  
José F Alfonso ◽  
Nuno Franqueira ◽  
Fernando Faria-Correira ◽  
Renato Ambrósio ◽  
...  

Purpose: The purpose was to compare the visual, refractive and aberrometric results of intrastromal corneal ring segments implantation with manual dissection and femtosecond laser–assisted surgery. Methods: This is a multicentre study, which included consecutive patients with paracentral keratoconus, in which the difference between the axes of the topographic flattest and the coma aberration was <60°, who had Ferrara-type intrastromal corneal ring segment implantation using manual dissection or femtosecond laser technique. LogMAR uncorrected (uncorrected distance visual acuity) and corrected (corrected distance visual acuity) distance visual acuity, refractive errors and the root mean square for corneal coma-like aberration were recorded before and at 6 months after surgery. Results: The study included 84 and 110 eyes in the manual group and in the femtosecond group, respectively. After surgery, there was a statistically significant improvement in uncorrected distance visual acuity and corrected distance visual acuity for both groups ( p < 0.0001), and there were no statistically significant differences between groups ( p > 0.3). For both groups, there was a reduction in spherical equivalent after intrastromal corneal ring segment implantation ( p < 0.0001). There were no statistically significant differences between groups in the magnitude of spherical equivalent reduction ( p = 0.34) The magnitude of the root mean square coma-like reduction was 0.93 ± 0.76 and 0.83 ± 0.80 μm in the manual and femtosecond group, respectively ( p = 0.2). While in the femtosecond laser group no complications were reported, in the manual group, the intraoperative or postoperative complications rate was 13.09%. Conclusion: Although both surgical techniques provide comparable visual, refractive and aberrometric outcomes, it should be noted that the femtosecond laser is a safer surgical procedure, with no complications reported.


2018 ◽  
Vol 30 (1) ◽  
pp. 125-131
Author(s):  
Cristina Peris-Martínez ◽  
Inmaculada Bueno-Gimeno ◽  
Izaskun Alvarez-Arana ◽  
David P Piñero ◽  
Andrés Gené-Sampedro

Purpose: To evaluate the visual, refractive, topographic, pachymetric, and biomechanical outcomes after intracorneal ring segment implantation in corneas with post-LASIK ectasia. Methods: Retrospective longitudinal study enrolling 26 eyes of 22 patients with post-LASIK ectasia and undergoing intracorneal ring segment implantation (KeraRing®, Mediphacos) using a 60-kHz femtosecond laser (IntraLase®, IntraLase Corp.) for corneal tunnelization. Visual, refractive, anterior, and posterior corneal topographic (Pentacam HR, Oculus), pachymetric, and corneal biomechanical changes (Ocular response Analyzer, Reichert) were evaluated during a 12-month follow-up. Vector analysis of astigmatic changes was performed. Results: A statistically significant reduction of sphere (p = 0.043) was observed at 1 month after surgery, with a significant improvement of uncorrected distance visual acuity associated (p = 0.019). Likewise, a significant reduction of anterior corneal power measurements (p ⩽ 0.014) and steepest posterior keratometric reading (p = 0.006) were observed at 1 month postoperatively, with no significant changes afterwards (p ⩾ 0.133). No significant changes were observed in manifest cylinder (p ⩾ 0.175), corrected distance visual acuity (p ⩾ 0.174), flattest posterior keratometric measurement (p ⩾ 0.282), volumetric measurements (p ⩾ 0.051), and corneal biomechanical parameters (p ⩾ 0.068). Vector analysis revealed an initial trend to overcorrection of astigmatism, with a trend to undercorrection at the end of follow-up and a significant variability in the outcome achieved in each patient. Conclusion: The implantation of KeraRing segments in post-LASIK corneal ectasia generates a significant modification of spherical refraction and a visual improvement due to a central corneal flattening generated. More refined nomograms of implantation in these cases should be developed to achieve a more predictable correction of astigmatism.


2021 ◽  
Vol 25 (6) ◽  
pp. 1-68
Author(s):  
Alexander C Day ◽  
Jennifer M Burr ◽  
Kate Bennett ◽  
Rachael Hunter ◽  
Catey Bunce ◽  
...  

Background Cataract surgery is one of the most common operations. Femtosecond laser-assisted cataract surgery (FLACS) is a technique that automates a number of operative steps. Objectives To compare FLACS with phacoemulsification cataract surgery (PCS). Design Multicentre, outcome-masked, randomised controlled non-inferiority trial. Setting Three collaborating NHS hospitals. Participants A total of 785 patients with age-related cataract in one or both eyes were randomised between May 2015 and September 2017. Intervention FLACS (n = 392 participants) or PCS (n = 393 participants). Main outcome measures The primary outcome was uncorrected distance visual acuity in the study eye after 3 months, expressed as the logarithm of the minimum angle of resolution (logMAR): 0.00 logMAR (or 6/6 if expressed in Snellen) is normal (good visual acuity). Secondary outcomes included corrected distance visual acuity, refractive outcomes (within 0.5 dioptre and 1.0 dioptre of target), safety and patient-reported outcome measures at 3 and 12 months, and resource use. All trial follow-ups were performed by optometrists who were masked to the trial intervention. Results A total of 353 (90%) participants allocated to the FLACS arm and 317 (81%) participants allocated to the PCS arm attended follow-up at 3 months. The mean uncorrected distance visual acuity was similar in both treatment arms [0.13 logMAR, standard deviation 0.23 logMAR, for FLACS, vs. 0.14 logMAR, standard deviation 0.27 logMAR, for PCS, with a difference of –0.01 logMAR (95% confidence interval –0.05 to 0.03 logMAR; p = 0.63)]. The mean corrected distance visual acuity values were again similar in both treatment arms (–0.01 logMAR, standard deviation 0.19 logMAR FLACS vs. 0.01 logMAR, standard deviation 0.21 logMAR PCS; p = 0.34). There were two posterior capsule tears in the PCS arm. There were no significant differences between the treatment arms for any secondary outcome at 3 months. At 12 months, the mean uncorrected distance visual acuity was 0.14 logMAR (standard deviation 0.22 logMAR) for FLACS and 0.17 logMAR (standard deviation 0.25 logMAR) for PCS, with a difference between the treatment arms of –0.03 logMAR (95% confidence interval –0.06 to 0.01 logMAR; p = 0.17). The mean corrected distance visual acuity was 0.003 logMAR (standard deviation 0.18 logMAR) for FLACS and 0.03 logMAR (standard deviation 0.23 logMAR) for PCS, with a difference of –0.03 logMAR (95% confidence interval –0.06 to 0.01 logMAR; p = 0.11). There were no significant differences between the arms for any other outcomes, with the exception of the mean binocular corrected distance visual acuity with a difference of –0.02 logMAR (95% confidence interval –0.05 to 0.00 logMAR) (p = 0.036), which favoured FLACS. There were no significant differences between the arms for any health, social care or societal costs. For the economic evaluation, the mean cost difference was £167.62 per patient higher for FLACS (95% of iterations between –£14.12 and £341.67) than for PCS. The mean QALY difference (FLACS minus PCS) was 0.001 (95% of iterations between –0.011 and 0.015), which equates to an incremental cost-effectiveness ratio (cost difference divided by QALY difference) of £167,620. Limitations Although the measurement of outcomes was carried out by optometrists who were masked to the treatment arm, the participants were not masked. Conclusions The evidence suggests that FLACS is not inferior to PCS in terms of vision after 3 months’ follow-up, and there were no significant differences in patient-reported health and safety outcomes after 12 months’ follow-up. In addition, the statistically significant difference in binocular corrected distance visual acuity was not clinically significant. FLACS is not cost-effective. Future work To explore the possible differences in vision in patients without ocular co-pathology. Trial registration Current Controlled Trials ISRCTN77602616. Funding This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 25, No. 6. See the NIHR Journals Library website for further project information. Moorfields Eye Charity (grant references GR000233 and GR000449 for the endothelial cell counter and femtosecond laser used).


Author(s):  
Paulo Ferrara ◽  
Leonardo Torquetti ◽  
Guilherme Ferrara

ABSTRACT Purpose To evaluate the long-term follow-up of Ferrara intrastromal corneal ring segments (ICRSs) (Ferrara Ophthalmics, Belo Horizonte, Brazil) implantation for the management of keratoconus in children. Study design Paulo Ferrara Eye Clinic, Belo Horizonte, Minas Gerais, Brazil. Materials and methods A total of 58 eyes of 37 children with keratoconus were included. One or two ring segments were inserted into the cornea, embracing the keratoconus area. Statistical analysis included preoperative and postoperative uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), asphericity, pachymetry, and keratometry. Results Ferrara ICRS implantation significantly improved the mean UDVA and CDVA. Corneal tomography (Pentacam®) showed corneal flattening in all eyes implanted with the Ferrara ring. The mean K decreased, and the corneal asphericity and pachymetry increased in all cases. Conclusion The Ferrara ICRS improved all parameters after 2 years of implantation in children with keratoconus. There was significant corneal flattening after ring implantation with improvement of the UDVA and the CDVA. All studied parameters remained stable over time. How to cite this article Ferrara G, Ferrara P, Torquetti L. Intrastromal Corneal Ring Segments in Children with Keratoconus. Int J Kerat Ect Cor Dis 2017;6(2):45-48.


2021 ◽  
Vol 10 (9) ◽  
pp. 1939
Author(s):  
José-María Sánchez-González ◽  
Federico Alonso-Aliste ◽  
Davide Borroni ◽  
Jonatan Amián-Cordero ◽  
Concepción De-Hita-Cantalejo ◽  
...  

To evaluate the usage of plasma rich in growth factor (PRGF) in transepithelial photorefractive keratectomy (TPRK) in low and moderate myopia, patients who underwent myopic and astigmatism TPRK with PRGF were involved in this retrospective, observational study. Subjects underwent a surgical procedure between February 2019 and June 2019. A three-month follow-up was recorded. Pain score was assessed with a visual analogue scale (0–10) and re-epithelialization time recorded. A total of 48 eyes from 24 patients were recruited. Mean uncorrected distance visual acuity (UDVA) was 20/20.31 (0.00 ± 0.02 LogMAR). A total of 98% of eyes did not change corrected distance visual acuity (CDVA) lines. Two percent of eyes lost one line of CDVA. Preoperative spherical equivalent was −2.67 ± 1.37 D and after three months changed to −0.21 ± 0.34 D, and 2% of eyes changed 0.50 D or more between one and three months. Pain score was 3.29 ± 0.61 (3 to 6) score points at day one and 0.08 ± 0.27 score points at day seven. Finally, re-epithelialization time was 2.50 ± 1.20 days. PRGF addition to conventional refractive treatment such as TPRK seems to alleviate immediate postoperative pain and positively contribute to corneal re-epithelization time.


Author(s):  
Pablo F Rodrigues ◽  
Wagner G Dias

ABSTRACT Purpose The purpose of this study is to evaluate the topographic, topometric and visual changes after implantation of Ferrara intrastromal corneal ring segments (ICRS) in grades I and II keratoconus patients. Materials and methods The chart records of 50 consecutively operated keratoconus patients were reviewed. The patients were operated on by the same surgeon, with the manual technique. All patients were preoperatively and postoperatively evaluated with the Pentacam (OCULUS Optikgeräte, Wetzlar, Germany). The studied parameters were: uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), keratometry, corneal asphericity and corneal volume. Results Fifty eyes of 42 patients (26 males and 16 females) were analyzed. The mean preoperative UDVA was 0.91 ranging from LogMAR 0.10 to 1.30. The mean postoperative CDVA was 0.19 ranging from 0.00 to 0.54 LogMAR. The postoperative CDVA was equal or better than 0.18 in 37 cases (74%). The mean K1 decreased from 45.80D (±2.52) preoperatively to 44.27D (± 2.10) postoperatively and the mean K2 value, from 49.06D (± 2.09) to 46.22D (±1.89). The mean asphericity increased from −0.71 preoperatively to −0.29 postoperatively. The average preoperative corneal volume was 56.89 ± 3.11 mm3 while the average postoperative corneal volume was 57.64 ± 3.05 mm3. Conclusion The study supports the early indication of implantation of Ferrara ICRS in mild to moderate keratoconus cases in order to achieve good visual, keratometric and ashpericity outcomes. How to cite this article Rodrigues PF, Ferrara G, Ferrara P, Dias WG, Torquetti L. Intrastromal Corneal Ring Segments Implantation in Patients with Mild Keratoconus. Int J Kerat Ect Cor Dis 2014;3(3):122-126.


2020 ◽  
Vol 13 (12) ◽  
pp. 1955-1960
Author(s):  
Sandro Coscarelli ◽  
Guilherme Rocha ◽  
Leonardo Torquetti

AIM: To evaluate the clinical results after implantation of a new intrastromal corneal ring segment (ICRS) associated with photorefractive keratectomy (PRK) to correct high myopia (HM) patients with thin corneas. METHODS: We evaluated 42 eyes of 23 HM patients that had ICRS implantation followed by PRK. The mean age of patients was 29.1±7.12y (range 18 to 40 years old). Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), keratometry, spherical equivalent, pachymetry, and aberrometry were compared using ANOVA with repeated measurements evaluated preoperatively and at last follow-up visit after the procedures. The refractive predictability and simulated/real corneal ablation were also assessed. RESULTS: The mean follow-up time after PRK was 6.8±1.6mo. The mean preoperative UCVA improved from 20/800 preoperative to 20/100 after ICRS and 20/35 after PRK. The mean preoperative BCVA was 20/25 (range from 20/30 to 20/20) and remained unchanged after ICRS implantation. Following the PRK the mean BCVA was 20/25 (range from 20/30 to 20/20). The mean spherical equivalent decreased from -7.25±1.12 (range -5.00 to -9.00) preoperatively to -3.32±1.0 (range -2.00 to -5.00) postoperatively (P<0.001) after ICRS implantation and decreased from -2.44±1.51 preoperatively to 0.32±0.45 (range -0.625 to 0.875) postoperatively (P<0.001) after PRK. The change in BCVA and topographic astigmatism was statistically significant (P<0.0001). CONCLUSION: ICRS in HM associated with PRK can be a tissue saving procedure and an alternative surgical option for correction of moderate to high myopia.


2020 ◽  
pp. 112067212090356
Author(s):  
Eliya Levinger ◽  
Michael Mimouni ◽  
Yaron Finkelman ◽  
Yossi Yatziv ◽  
Jonathan Shahar ◽  
...  

Purpose: The purpose of this study was to assess the results of a sulcus intraocular lens (Sulcoflex) for pseudophakic refractive errors following phacoemulsification cataract surgery. Methods: This retrospective clinical observational cohort study included consecutive eyes in which a Sulcoflex was implanted. Uncorrected distance visual acuity and corrected distance visual acuity as well as refractive outcomes were assessed. The minimum follow-up time required for inclusion was 3 months. Results: In total, 15 eyes ( n = 15) were evaluated. The mean follow-up was 14 months (range: 3–18 months). The Sulcoflex aspheric (653L) was implanted in 13 eyes and the Sulcoflex toric (653T) in two eyes. The preoperative mean logMAR (Snellen) uncorrected distance visual acuity and corrected distance visual acuity were 0.88 (20/150) and 0.27 (20/40), respectively. The postoperative mean logMAR (Snellen) corrected distance visual acuity was 0.15 (20/30). The preoperative mean spherical equivalent was −0.22 ± 5.95 D and the postoperative mean spherical equivalent was −1.59 ± 1.45 D. There was a significant and strong correlation ( r = 0.64, p < 0.001) between the attempted and the achieved spherical equivalent. Conclusion: The Sulcoflex is a safe and viable option for patients with residual refractive error following cataract surgery.


2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
C. Lisa ◽  
R. Zaldivar ◽  
A. Fernández-Vega Cueto ◽  
R. M. Sanchez-Avila ◽  
D. Madrid-Costa ◽  
...  

Purpose. To evaluate efficacy, safety, and predictability of sequential Ferrara-type intrastromal corneal ring segments (ICRS) and an extended range of vision intraocular lens (IOL) implantation in patients with keratoconus and cataract. Methods. This study comprised patients with keratoconus and cataract that had ICRS implantation followed 6 months later by extended range of vision IOL implantation. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and residual refractive errors, analysed using vector analysis, were recorded preoperatively, 6 months after ICRS implantation, and 6 months after IOL implantation, respectively. Results. The study enrolled 17 eyes (11 patients). The mean UDVA (logMAR scale) was 1.15 ± 0.67 preoperatively, 0.88 ± 0.69 six months after ICRS implantation (P=0.005), and 0.27 ± 0.18 six months after IOL implantation (P<0.0001). The CDVA changed from 0.26 ± 0.15 (logMAR) before surgery to 0.17 ± 0.08 six months after Ferrara-type ICRS implantation (P=0.002) and to 0.07 ± 0.06 six months after IOL implantation (P<0.0001). The spherical equivalent and the refractive cylinder declined steeply after IOL implantation (P<0.001). The magnitude of depth of focus was 2.60 ± 1.02 D. There were no statistically significant differences in visual acuity for a defocus range from +0.50 D to −0.50 D (P>0.1). Conclusion. Sequential Ferrara-type ICRS and an extended range of vision IOL implantation provided good visual and refractive outcomes, being an effective, safe, and predictable procedure for the treatment of selected cases of patients with keratoconus and cataract. In addition, this approach provides an increase of tolerance to defocus.


Sign in / Sign up

Export Citation Format

Share Document