scholarly journals Long-Term Destiny of Corneal Endothelial Cells in Anterior Chamber Intraocular Lens-Implanted Eyes

2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Yating Tang ◽  
Jie Xu ◽  
Jiahui Chen ◽  
Yi Lu

Purpose. To investigate the long-term changes of corneal endothelial cells (EC) in anterior chamber intraocular lens- (AC-IOL-) implanted eyes. Methods. Retrospective study. We included 37 eyes (25 patients) that received AC-IOL implantation previously in the Eye and ENT Hospital of Fudan University between 1995 and 2016. Follow-up outcomes included the best-corrected visual acuity (BCVA), endothelial cell density, hexagonality, coefficient of variance, and central corneal thickness. Results. In total, 23 eyes (62.16%) with phakic and 14 eyes (37.84%) with aphakic AC-IOLs were included. Among these, 3 eyes (8.11%) were angle-supported AC-IOLs and 34 eyes (91.89%) were Artisan iris-fixated AC-IOLs. The mean age of patients was 41.40 ± 17.17 years, and the mean follow-up time was 12.12 ± 4.71 years in our study. At the follow-up time, corneal decompensation existed in 3 angle-supported AC-IOL eyes with a rate of 100% and 15 iris-fixated AC-IOL eyes with a rate of 44.12%. AC-IOL displacement occurred in 14 (41.18%) iris-fixated AC-IOL eyes. In the 19 iris-fixated AC-IOL eyes without corneal decompensation, significant changes also took place in corneal endothelial cells. The endothelial cell density decreased from 2843.26 ± 300.76 to 2015.58 ± 567.99 cells/mm2 (29.1% loss, P < 0.001 ) and hexagonality decreased from 51.21 ± 7.83 to 42.53 ± 9.17 (%) (16.9% loss, P < 0.001 ). The Kaplan–Meier survival curve also demonstrated the accumulated expectation rates of corneal endothelial cell decomposition for AC-IOLs with a median survival time of 12 years. Conclusion. We reported a significant chronic loss and long-term decompensation destiny of corneal endothelial cells in AC-IOL eyes. Semiannual or annual follow-up and evaluation of endothelial cells should be conducted in AC-IOL-implanted patients.

2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Ji Won Seo ◽  
Jong Yeon Lee ◽  
Dong Heun Nam ◽  
Dae Yeong Lee

Purpose. To compare the changes in corneal endothelial cells after pars plana Ahmed glaucoma valve (AGV) implantation with those after the anterior chamber AGV implantation for refractory glaucoma.Methods. The medical records of 18 eyes with pars plana implantation of AGV (ppAGV) were reviewed retrospectively and were compared with 18 eyes with the anterior chamber AGV (acAGV) implant. The preoperative and postoperative endothelial cells, intraocular pressure (IOP), and postoperative complications during the follow-up in both groups were compared.Results. The average follow-up was 18 months. The postoperative endothelial cells in the ppAGV and acAGV groups were 2044 ± 303 and 1904 ± 324, respectively(P=0.25). The average percentage decrease in the endothelial cells in the ppAGV and acAGV groups at 18 months was 12.5% and 18.4%, respectively, and showed significant difference between the 2 groups(P=0.01). No difference in IOP control and the number of postoperative glaucoma medications was observed between the 2 groups.Conclusions. Endothelial cell damage in the ppAGV group for refractory glaucoma appeared to be lower than that in the acAGV group. Therefore, pars plana implantation of AGV may be preferred as it may have lower level of endothelial cell damage while maintaining similar level of IOP control.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Tatsuya Jujo ◽  
Jiro Kogo ◽  
Hiroki Sasaki ◽  
Reio Sekine ◽  
Keiji Sato ◽  
...  

Abstract Backgrounds However there have been numerous investigations of intrascleral intraocular lens (IOL) fixation techniques, there is room for improvement in terms of simplifying complicated techniques and reducing the high levels of skill required. This study aimed to report a novel technique for sutureless intrascleral fixation of the IOL using retinal forceps with a 27-gauge trocar. Methods Nineteen eyes of 18 patients underwent intrascleral fixation of the IOL from July 2018 to September 2019 were enrolled in this study. A 27-gauge trocar formed 3-mm scleral tunnels positioned at 4 and 10 o’clock, 2 mm from the corneal limbus. We used a 3-piece IOL haptic grasped by a 27-gauge retinal forceps and pulled from the 27-gauge trocar. The IOL was fixed by making a flange. Main outcome measures were visual acuity, corneal endothelial cell density, IOL tilt, decentration, predicted error of refraction and complications. Results The 19 eyes were followed up for 1 month. The mean pre- and postoperative logMAR uncorrected visual acuity (UCVA) was 1.06 ± 0.63 and 0.40 ± 0.26, respectively (p < 0.01), while the mean pre- and postoperative logMAR best corrected visual acuity (BCVA) was 0.27 ± 0.51 and 0.06 ± 0.15, respectively (p = 0.09). The mean corneal endothelial cell density was 2406 ± 625 to 2004 ± 759 cells/mm2 at 1 month (p = 0.13). The mean IOL tilt was 3.52 ± 3.00°, and the mean IOL decentration was 0.39 ± 0.39 mm. There was no correlation among IOL tilt, decentration and BCVA (p > 0.05). The mean prediction error of the target refraction was − 0.03 ± 0.93 D. The complications were vitreous hemorrhage (3 eyes), hyphema (1 eye), IOP elevation (1 eye), iris capture of the IOL (1 eye) and hypotony (2 eyes). No IOL dislocation occurred. Conclusions IOL intrascleral fixation with a flange achieved good IOL fixation and visual outcome in the scleral tunnels created with the 27-gauge trocar.


2021 ◽  
pp. 112067212198963
Author(s):  
Martina Menchini ◽  
Francesco Sartini ◽  
Filippo Tatti ◽  
Enrico Peiretti ◽  
Michele Figus

Purpose: To report a case of fully dislocated XEN Gel Implant device into the anterior chamber, 18 months after its implantation and its impact on endothelial cell density. Result: A 75-year-old man with a history of multiple glaucoma surgeries during the last three years presented with an entirely dislocated XEN Gel implant into the anterior chamber. An endothelial cell density reduction was observed over 18 months. Thus, the implant was removed. In the short-term after surgery, the endothelial cell loss rate reduced. Conclusion: XEN Gel Implant can dislocate into the anterior chamber, increasing endothelial cell loss in an eye already underwent multiple surgical procedures with subsequent adverse events. Therefore, if the implant seems displaced, the endothelial cell density should be monitored, and the length of the free-tube segment within the anterior chamber should be measured, during the patient’s follow-up.


2012 ◽  
Vol 38 (2) ◽  
pp. 368-372 ◽  
Author(s):  
Andrew Ollerton ◽  
Brian C. Stagg ◽  
Lisa Leishman ◽  
Zachary Bodnar ◽  
Liliana Werner ◽  
...  

2018 ◽  
Vol 22 (2) ◽  
pp. 177-182
Author(s):  
Natàlia Coyo ◽  
Marta Leiva ◽  
Daniel Costa ◽  
Rafael Molina ◽  
Olga Nicolás ◽  
...  

1998 ◽  
Vol 24 (11) ◽  
pp. 1515-1520 ◽  
Author(s):  
Tatsu Sawada ◽  
Wataru Kimura ◽  
Tohru Kimura ◽  
Hideki Suga ◽  
Akitoshi Ohte ◽  
...  

Ophthalmology ◽  
2008 ◽  
Vol 115 (4) ◽  
pp. 608-613.e1 ◽  
Author(s):  
Ruchi Saxena ◽  
Sharmila S. Boekhoorn ◽  
Paul G.H. Mulder ◽  
Bastiaantje Noordzij ◽  
Gabriel van Rij ◽  
...  

2020 ◽  
Vol 36 (4) ◽  
Author(s):  
Abd Elaziz Mohamed Elmadina ◽  
Raghda Faisal Abdelfatah ◽  
Saif Hassan Alrasheed ◽  
Mustafa Abdu ◽  
Manzoor Ahmad Qureshi

Purpose:  To compare the corneal endothelial cells morphology and central corneal thickness (CCT) before and after phacoemulsification in Sudanese population. Place and Duration of Study:  Al-Neelain eye hospital, Khartoum, Sudan, from January 2018 to May 2018. Study Design:  Observational longitudinal study. Methods:  One hundred and forty eyes of 140 patients with immature senile cataract were selected by convenient sampling. The age ranged from 40 to 85 years. The patients underwent complete ocular examination including morphology of corneal endothelial cells and CCT using computerized non-contact specular microscope. Inclusion criteria for the study was eyes with normal corneal endothelial cells and cell density more than 1000 cells/mm2. We excluded patients with ocular or systemic diseases, previous history of intraocular surgery, refractive surgery or trauma as well as contact lenses wear. The patients underwent phacoemulsification by a single surgeon. The examination parameters were repeated one month after surgery. Descriptive and comparative statistical analyses were performed using SPSS for Windows Version 21.0. Results:  There was significant reduction in mean endothelial cells density after phacoemulsification compared to baseline with p < 0.001. There was also significant post-operative reduction in mean endothelial cells number as compared to baseline (P value < 0.001). Mean endothelial cells hexagonality was reduced after surgery with P value of 0.003. No significant difference was found between mean coefficient variation of endothelial cells size before and after phacoemulsification (P = 0.55). Central corneal thickness showed significant increase post-operatively, P = 0.003. Conclusion:  Phacoemulsification causes significant damage to corneal endothelium cells, including decrease in corneal endothelial cell density, hexagonality and cell number. Key Words:  Corneal endothelium, Endothelial cell density, Central corneal thickness, Phacoemulsification.


Sign in / Sign up

Export Citation Format

Share Document