scholarly journals The Number of Frames on ECG-Gated 18F-FDG Small Animal PET Has a Significant Impact on LV Systolic and Diastolic Functional Parameters

2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Christoph Eissler ◽  
Rudolf A. Werner ◽  
Paula Arias-Loza ◽  
Naoko Nose ◽  
Xinyu Chen ◽  
...  

Objectives. This study is aimed at investigating the impact of frame numbers in preclinical electrocardiogram- (ECG-) gated 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) on systolic and diastolic left ventricular (LV) parameters in rats. Methods. 18F-FDG PET imaging using a dedicated small animal PET system with list mode data acquisition and continuous ECG recording was performed in diabetic and control rats. The list-mode data was sorted and reconstructed with different numbers of frames (4, 8, 12, and 16) per cardiac cycle into tomographic images. Using an automatic ventricular edge detection software, left ventricular (LV) functional parameters, including ejection fraction (EF), end-diastolic (EDV), and end-systolic volume (ESV), were calculated. Diastolic variables (time to peak filling (TPF), first third mean filling rate (1/3 FR), and peak filling rate (PFR)) were also assessed. Results. Significant differences in multiple parameters were observed among the reconstructions with different frames per cardiac cycle. EDV significantly increased by numbers of frames (353.8 ± 57.7 μl ∗ , 380.8 ± 57.2 μl ∗ , 398.0 ± 63.1 μl ∗ , and 444.8 ± 75.3 μl at 4, 8, 12, and 16 frames, respectively; ∗ P < 0.0001 vs. 16 frames), while systolic (EF) and diastolic (TPF, 1/3 FR and PFR) parameters were not significantly different between 12 and 16 frames. In addition, significant differences between diabetic and control animals in 1/3 FR and PFR in 16 frames per cardiac cycle were observed ( P < 0.005 ), but not for 4, 8, and 12 frames. Conclusions. Using ECG-gated PET in rats, measurements of cardiac function are significantly affected by the frames per cardiac cycle. Therefore, if you are going to compare those functional parameters, a consistent number of frames should be used.

Author(s):  
Leticia Ortega Maynez ◽  
Humberto de Jesus Ochoa Dominguez ◽  
Osslan Osiris Vergara Villegas ◽  
Vianey Guadalupe Cruz Sanchez ◽  
Jose Manuel Mejia Munoz

PLoS ONE ◽  
2018 ◽  
Vol 13 (10) ◽  
pp. e0205610 ◽  
Author(s):  
Lorena Cussó ◽  
Manuel Desco

2009 ◽  
Vol 50 (6) ◽  
pp. 966-973 ◽  
Author(s):  
A. S. Yu ◽  
H.-D. Lin ◽  
S.-C. Huang ◽  
M. E. Phelps ◽  
H.-M. Wu

2004 ◽  
Vol 31 (2) ◽  
pp. 251-256 ◽  
Author(s):  
Hiroshi Toyama ◽  
Masanori Ichise ◽  
Jeih-San Liow ◽  
Douglass C. Vines ◽  
Nicholas M. Seneca ◽  
...  

2009 ◽  
Vol 50 (11) ◽  
pp. 1848-1856 ◽  
Author(s):  
K. McLarty ◽  
A. Fasih ◽  
D. A. Scollard ◽  
S. J. Done ◽  
D. C. Vines ◽  
...  

2008 ◽  
Vol 35 (1) ◽  
pp. 143-150 ◽  
Author(s):  
Sang-Keun Woo ◽  
Tae Sup Lee ◽  
Kyeong Min Kim ◽  
June-Youp Kim ◽  
Jae Ho Jung ◽  
...  

Oncotarget ◽  
2016 ◽  
Vol 7 (19) ◽  
pp. 28247-28261 ◽  
Author(s):  
Valerie S. Honndorf ◽  
Stefan Wiehr ◽  
Anna-Maria Rolle ◽  
Julia Schmitt ◽  
Luisa Kreft ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document