scholarly journals Interventional optical imaging permits instant visualization of pathological zones of ablated tumor periphery and residual tumor detection

2021 ◽  
pp. canres.1040.2021
Author(s):  
Xuefeng Kan ◽  
Guanhui Zhou ◽  
Feng Zhang ◽  
Hongxiu Ji ◽  
Hui Zheng ◽  
...  
2008 ◽  
Vol 14 (8) ◽  
pp. 2295-2302 ◽  
Author(s):  
Peter Brader ◽  
Jochen Stritzker ◽  
Christopher C. Riedl ◽  
Pat Zanzonico ◽  
Shangde Cai ◽  
...  

2011 ◽  
Author(s):  
Jae Youn Hwang ◽  
Zeev Gross ◽  
Harry B. Gray ◽  
Lali K. Medina-Kauwe ◽  
Daniel L. Farkas

2019 ◽  
Vol 94 (3) ◽  
pp. 374-375
Author(s):  
Luis Fernando Figueiredo Kopke

Radiology ◽  
1999 ◽  
Vol 213 (3) ◽  
pp. 866-870 ◽  
Author(s):  
Umar Mahmood ◽  
Ching-Hsuan Tung ◽  
Alexei Bogdanov ◽  
Ralph Weissleder

2013 ◽  
Vol 91 (2) ◽  
pp. 182-186 ◽  
Author(s):  
Evren Süer ◽  
Cihat Özcan ◽  
Sümer Baltaci ◽  
Ömer Gülpinar ◽  
Berk Burgu ◽  
...  

2019 ◽  
Vol 44 (2) ◽  
pp. e76-e84 ◽  
Author(s):  
Ana María García Vicente ◽  
María José Rodriguez Muñoz ◽  
Francisco José Pena Pardo ◽  
Milton Miguel Martinez Madrigal ◽  
Angel Soriano Castrejón

2020 ◽  
Vol 27 (6) ◽  
pp. 1854-1861 ◽  
Author(s):  
Barbara L. Smith ◽  
Conor R. Lanahan ◽  
Michelle C. Specht ◽  
Bridget N. Kelly ◽  
Carson Brown ◽  
...  

Abstract Background Obtaining tumor-free margins is critical to prevent recurrence after lumpectomy for breast cancer. Unfortunately, current approaches leave positive margins that require second surgeries in 20–40% of patients. We assessed the LUM Imaging System for real-time, intraoperative detection of residual tumor. Methods Breast lumpectomy cavity walls and excised specimens were assessed with the LUM Imaging System after 1 mg/kg intravenous LUM015, a protease-activatable fluorescent agent. Fluorescence at potential sites of residual tumor in lumpectomy cavity walls was evaluated intraoperatively with a sterile hand-held probe, with real-time predictive results displayed on a monitor intraoperatively, and later correlated with histopathology. Results In vivo lumpectomy cavities and excised specimens were imaged after LUM015 injection in 45 women undergoing breast cancer surgery. Invasive ductal and lobular cancers and intraductal cancer (DCIS) were included. A total of 570 cavity margin surfaces in 40 patients were used for algorithm development. Image analysis and display took approximately 1 s per 2.6-cm-diameter circular margin surface. All breast cancer subtypes could be distinguished from adjacent normal tissue. For all imaged cavity surfaces, sensitivity for tumor detection was 84%. Among 8 patients with positive margins after standard surgery, sensitivity for residual tumor detection was 100%; 2 of 8 were spared second surgeries because additional tissue was excised at sites of LUM015 signal. Specificity was 73%, with some benign tissues showing elevated fluorescent signal. Conclusions The LUM015 agent and LUM Imaging System allow rapid identification of residual tumor in the lumpectomy cavity of breast cancer patients and may reduce rates of positive margins.


2011 ◽  
Vol 20 (5) ◽  
pp. 397-415 ◽  
Author(s):  
Metasebya Solomon ◽  
Yang Liu ◽  
Mikhail Y. Berezin ◽  
Samuel Achilefu

Sign in / Sign up

Export Citation Format

Share Document