scholarly journals In vitro Detection of Occlusal Caries on Permanent Teeth by a Visual, Light-Induced Fluorescence and Photothermal Radiometry and Modulated Luminescence Methods

2015 ◽  
Vol 49 (5) ◽  
pp. 523-530 ◽  
Author(s):  
Mahmoud Jallad ◽  
Domenick Zero ◽  
George Eckert ◽  
Andrea Ferreira Zandona

Background: The paradigm shift towards the nonsurgical management of dental caries relies on the early detection of the disease. Detection of caries at an early stage is of unequivocal importance for early preventive intervention. Objective: The aim of this in vitro study is to evaluate the performance of a visual examination using the International Caries Detection and Assessment System (ICDAS) criteria, two quantitative light-induced fluorescence (QLF) systems - Inspektor™ Pro and QLF-D Biluminator™ 2 (Inspektor Research Systems B.V., Amsterdam, The Netherlands) - and a photothermal radiometry and modulated luminescence, The Canary System® (Quantum Dental Technologies, Toronto, Ont., Canada) on the detection of primary occlusal caries on permanent teeth. Methods: A total of 60 teeth with occlusal surface sites ranging from sound to noncavitated lesions (ICDAS 0-4) were assessed with each detection method twice in a random order. Histological validation was used to compare methods for sensitivity, specificity, percent correct, and the area under the receiver operating characteristic curve (AUC), at standard and optimum sound thresholds. Interexaminer agreement and intraexaminer repeatability were measured using intraclass correlation coefficients. Results: Interexaminer agreement ranged between 0.48 (The Canary System®) and 0.96 (QLF-D Biluminator™ 2). Intraexaminer repeatability ranges were 0.33-0.63 (The Canary System®) and 0.96-0.99 (QLF-D Biluminator™ 2). The sensitivity range was 0.75-0.96 while that of specificity was 0.43-0.89. The AUC were 0.79 (The Canary System®), 0.87 (ICDAS), 0.90 (Inspektor™ Pro), and 0.94 (QLF-D Biluminator™ 2). Conclusion: ICDAS had the best combination of sensitivity and specificity followed by QLF-D Biluminator™ 2 at optimum threshold.

2011 ◽  
Vol 36 (2) ◽  
pp. 133-142 ◽  
Author(s):  
MB Diniz ◽  
LM Lima ◽  
G Eckert ◽  
AG Ferreira Zandona ◽  
RCL Cordeiro ◽  
...  

Clinical RelevanceIt has been suggested that occlusal caries detection has become more difficult due to the widespread use of fluoride, which slows down lesion progression and delays cavitation. The ability to detect caries lesions at an early stage has a significant impact on treatment decisions, improving the possibility for a successful preventive intervention. In this investigation, the authors found that the International Caries Detection and Assessment System associated with radiographic examination has the potential to support treatment decisions for occlusal surfaces.


2019 ◽  
Vol 43 (3) ◽  
pp. 173-179
Author(s):  
Murat Ünal ◽  
Arzu Koçkanat ◽  
Seniha Güler ◽  
Esra Gültürk

Aim: This in vitro study was aimed to investigate the performance of the new caries detection tools on the incipient occlusal caries. Study design: In our study, 100 permanent molar teeth, which were considered to have incipient, enamel caries (D1 and D2 threshold values) according to ICDAS II score. After the visual examination, caries measurements have been applied to all teeth by using DIAGNOdent pen (DP), CarieScan PRO (CP) and SoproLife camera (SC). In addition, in vitro examinations were repeated 2 weeks later. After sectioning and evaluation in stereomicroscope, the lesion depth was determined with histological criteria that are accepted for the gold standard for this research. Sensitivity, specificity, accuracy and area under the ROC curve were calculated at D1 and D2 thresholds. The intra-examiners' reproducibility were analysed using Cohen's kappa statistics and intraclass correlation coefficient (ICC). Results: Intra-examiner repeatability values varied from 0.94 to 0.99 and kappa values ranged from 0.90 to 0.99. While the highest sensitivity and specificity value showed for SC at D1 and D2 thresholds, CP presented the lowest values. The area under ROC curves (Az) varied from 0.70 to 0.99. ICDAS II showed the highest area under ROC curves (Az). Conclusions: ICDAS II, visual diagnostic method by itself is considered to sufficient in order to diagnose incipient occlusal caries. SC may be used as an alternative method for the ICDAS II, since its advantages by displaying caries lesion on the computer monitor, follow-up and motivation of the patients provided.


2018 ◽  
Vol 43 (3) ◽  
pp. E152-E157 ◽  
Author(s):  
JK Mitchell ◽  
AR Furness ◽  
RJ Sword ◽  
SW Looney ◽  
WW Brackett ◽  
...  

SUMMARYDiagnosis of the extent of pit-and-fissure caries has been subjective and thus difficult to teach and categorize for treatment planning. This in vitro study compares occlusal caries diagnosis of extracted posterior teeth (n=49) using three-dimensional (3D) scanned images vs visual examination, according to the International Caries Detection and Assessment System (ICDAS). The surfaces chosen for study represent all ICDAS classifications. Five experienced restorative faculty members examined scanned images for 60 seconds from a standardized series of views of each surface and scored them independently. One month later, the same teeth were examined visually by the same five raters with magnification and LED headlamps, with compressed air available. Intrarater and interrater agreement and validity were assessed using intraclass correlation coefficients (ICCs). The ICCs, ranging from 0.90 to 0.93, indicated excellent agreement between and within raters and between the raters and the gold standard ICDAS determination. This suggests that both photographs and 3D scans of pits and fissures are equally effective in diagnosing caries.


2015 ◽  
Vol 40 (5) ◽  
pp. E189-E196 ◽  
Author(s):  
FVMD Cotta ◽  
LS de Castilho ◽  
AN Moreira ◽  
SM Paiva ◽  
EF Ferreira ◽  
...  

SUMMARY Objective The aim of this study was to investigate the clinical performance and to validate the Lesion Activity Assessment (LAA) in conjunction with the International Caries Detection and Assessment System (ICDAS) for occlusal caries diagnosis in permanent teeth. Methods Patients with erupted or partially erupted third molars were recruited from the surgery clinic of the School of Dentistry of the Universidade Federal de Minas Gerais, Brazil. A calibrated examiner evaluated 49 teeth using the ICDAS-LAA criteria. The histologic criterion proposed by Ekstrand and others was used to validate severity at the thresholds D1 (outer half of the enamel), D2 (inner half of the enamel and outer third of the dentin), and D3 (inner or middle third of the dentin). Lesion activity was validated using 0.1% methyl red solution. Results The method demonstrated good reliability (weighted kappa for severity=0.60; unweighted kappa for activity=0.61). The ICDAS presented a higher performance for lesion detection (area under the receiver operating characteristic curve [Az]=0.79) using the threshold D3. At the thresholds D1 and D2, the results for Az were 0.57 and 0.74, respectively. Regarding the ICDAS-LAA, Az = 0.59. Conclusions Clinical protocols can use ICDAS for the severity diagnosis of occlusal caries, but the LAA performance was poor.


2016 ◽  
Vol 41 (1) ◽  
pp. 34-43 ◽  
Author(s):  
MB Diniz ◽  
RCL Cordeiro ◽  
AG Ferreira-Zandona

SUMMARYTo evaluate the in vitro performance of the International Caries Detection and Assessment System (ICDAS) visual examination, bitewing radiography (BW), and the DIAGNOdent 2190, a pen-type laser fluorescence device (LFpen), in detecting caries around amalgam restorations on approximal surfaces. Approximal surfaces (N=136) of permanent posterior teeth (N=110) with Class II amalgam restorations were assessed twice by two experienced examiners using ICDAS, BW, and LFpen. The occurrence of proximal overhangs was also evaluated. The teeth were histologically prepared and assessed for caries extension. Different cutoff limits for the LFpen were used. Intraexaminer and interexaminer reproducibility showed moderate to good agreement for all the methods (weighted κ/intraclass correlation coefficient=0.40 to 0.87). The specificities at D1 (all visible lesions affecting enamel) and D3 (lesions extended into dentin) were, respectively, 0.41 and 0.82 for ICDAS, 0.70 and 0.82 for BW, and 0.77-0.89 and 0.88-0.94 for LFpen. The sensitivities were 0.80 and 0.52 for ICDAS, 0.56 and 0.51 for BW, and 0.04-0.23 and 0.01-0.02 for LFpen at D1 and D3, respectively. At the D1/D3 thresholds, the accuracy and the area under the receiver operating characteristic curve (Az) values were similar and statistically higher for ICDAS (0.65/0.68 and 0.633/0.688) and BW (0.64/0.68 and 0.655/0.719), respectively; whereas, LFpen presented lower accuracy (0.37-0.44/0.49-0.52) and Az (0.390-0.454/0.345-0.395) values. The occurrence of overhangs (26.8%) was shown to be irrelevant in determining the presence of secondary caries. The ICDAS and BW methods presented the best performance in detecting caries lesions affecting enamel and dentin on approximal surfaces of amalgam restorations.


2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
Mona Zeitouny ◽  
Mireille Feghali ◽  
Assaad Nasr ◽  
Philippe Abou-Samra ◽  
Nadine Saleh ◽  
...  

Objectives.The aim of this study was to evaluate a light-emitting diode fluorescence tool, the SOPROLIFE light-induced fluorescence evaluator, and compare it to the international caries detection and assessment system-II (ICDAS-II) in the detection of occlusal caries. Methods. A total of 219 permanent posterior teeth in 21 subjects, with age ranging from 15 to 65 years, were examined. An intraclass correlation coefficient (ICC) was computed to assess the reliability between the two diagnostic methods.Results.The results showed a high reliability between the two methods (ICC = 0.92; IC = 0.901–0.940;P<0.001). The SOPROLIFE blue fluorescence mode had a high sensitivity (87%) and a high specificity (99%) when compared to ICDAS-II.Conclusion.Compared to the most used visual method in the diagnosis of occlusal caries lesions, the finding from this study suggests that SOPROLIFE can be used as a reproducible and reliable assessment tool. At a cut-off point, categorizing noncarious lesions and visual change in enamel, SOPROLIFE shows a high sensitivity and specificity. We can conclude that financially ICDAS is better than SOPROLIFE. However SOPROLIFE is easier for clinicians since it is a simple evaluation of images. Finally in terms of efficiency SOPROLIFE is not superior to ICDAS but tends to be equivalent with the same advantages.


2016 ◽  
Vol 124 (2) ◽  
pp. 188-194 ◽  
Author(s):  
Lia S. Castilho ◽  
Fernanda V. M. D. Cotta ◽  
Audrey C. Bueno ◽  
Allyson N. Moreira ◽  
Efigênia F. Ferreira ◽  
...  

2015 ◽  
Vol 49 (4) ◽  
pp. 401-407 ◽  
Author(s):  
Qingguang Chen ◽  
Haihua Zhu ◽  
Ying Xu ◽  
Bin Lin ◽  
Hui Chen

The feasibility of colorimetric parameters for the discrimination of the stages of dental caries based on a light-induced autofluorescence spectrum at a 405-nm excitation wavelength was investigated. The fluorescence spectra of 4 groups of tooth samples (10 sound, 10 early-stage decay, 14 established decay, and 10 severe decay), which were classified by the International Caries Detection and Assessment System, were experimentally measured in vitro. The carious lesion samples had an additional fluorescence peak at around 627 nm. The mathematical relation of the fluorescence spectrum and human color perception was established and computed. With increasing severity, the fluorescence color changed from green to yellow according to the colorimetric parameters of the CIE 1931 (x, y) chromaticity coordinates and dominant wavelengths. The results from a one-way ANOVA of the dominant wavelength showed a statistically significant difference among the 4 classified groups. The colorimetric parameters of the light-induced fluorescence spectrum can potentially be applied to evaluate the various carious levels.


Author(s):  
Rabia Sannam Khan

Introduction: Dental care for older population is becoming a matter of concern within the National health services (NHS) United Kingdom (UK) due to increasing life expectancy of older people and retention of their natural teeth. The aim of study was to relate the International Caries Detection and Assessment System (ICDAS) scores with severity index in order to detect root caries and DIAGNOdent readings, at an early stage, to manage these lesions non-invasively. Methods: Fresh 95 extracted teeth were collected from Oral Surgery and Dental Emergency Department at Barts and the London, Queen Mary University of London. In this in vitro study, 19 out of 95 teeth had root caries. Prior to recording the readings, extracted teeth were cleaned and polished. Each lesion underwent clinical examination. To detect root caries DIAGNOdent readings (ICDAS), severity index were obtained. Pearson’s correlation coefficients tests were applied. Results: The correlation between cavitation and ICDAS scores shows the significant value of 0.01. The DIAGNOdent reading with momentum and peak values was 45.37 with standard deviation of 32.16 and for peak with the mean value of 49.79 and 31.72 of standard deviation. Regarding, readings of DIAGNOdent and severity index establishment of correlation was difficult to establish. The reason was score of severity index regarding specimen no.1 is 3.3 was illustrative of lesion that is leathery. Conclusion: The DIAGNOdent readings system did not support the detection of root caries. However, the severity index scoring system is in need of greater categories regarding caries of the root.


Sign in / Sign up