Abstract P121: Automated Messaging Program To Facilitate Systematic Home Blood Pressure Monitoring: A Qualitative Analysis Of Provider Interviews

Hypertension ◽  
2021 ◽  
Vol 78 (Suppl_1) ◽  
Author(s):  
Andrew R Murphy ◽  
Julian Einhorn ◽  
Shari Rogal ◽  
Danielle Burton ◽  
Brian P Suffoletto ◽  
...  

Introduction: Hypertension is a leading cause of morbidity worldwide. Home blood pressure monitoring (HBPM) has been shown to lower blood pressure (BP) if paired with co-interventions but such programs are not routinely used in clinical care. MyBP is an automated bi-directional text messaging HBPM program that assists lowering of BP, but how to best implement within clinical care remains unknown. Therefore, in this study, we sought stakeholder input from care providers. Methods: We conducted semi-structured interviews (average recorded duration 28 minutes) with physicians, nurses, and medical assistants from primary care settings, most of whom had participated in a feasibility trial of MyBP. The interview was designed around constructs from the Consolidated Framework for Implementation Research. Interviews were transcribed verbatim and analyzed using inductive coding to organize meaningful excerpts and identify salient themes. Results: Subjects were physicians (n = 11) and nurses/medical assistants (n = 6). Care providers felt that patients benefitted from MyBP’s positive influence on BP measurement adherence, psychological factors (such as health literacy and patient empowerment), and perceived patient usability of the program. They reported that the program data aided in clinical diagnosis and management of HTN with a practical user interface for providers. Barriers to implementation included lack of integration into the electronic medical record and difficulty in training office staff in its use. Conclusion: In this qualitative analysis of care provider stakeholders, MyBP was seen as a pragmatic and effective way to empower patients in BP self-management and tangibly aid providers. Future research will need to focus on strategies to overcome implementation barriers to facilitate integration in to the clinical and digital environment.

2019 ◽  
Vol 102 (12) ◽  
pp. 2246-2253
Author(s):  
Matthew E. Allen ◽  
Taya Irizarry ◽  
Julian Einhorn ◽  
Thomas W. Kamarck ◽  
Brian P. Suffoletto ◽  
...  

2021 ◽  
Vol 33 (7-8_suppl) ◽  
pp. 40S-50S
Author(s):  
Krista R. Schaefer ◽  
Amber L. Fyfe-Johnson ◽  
Carolyn J. Noonan ◽  
Michael R. Todd ◽  
Jason G. Umans ◽  
...  

Objectives: Home blood pressure monitoring (HBPM) is an important component of blood pressure (BP) management. We assessed performance of two HBPM devices among Alaska Native and American Indian people (ANAIs). Methods: We measured BP using Omron BP786 arm cuff, Omron BP654 wrist cuff, and Baum aneroid sphygmomanometer in 100 ANAIs. Performance was assessed with intraclass correlation, paired t-tests, and calibration models. Results: Compared to sphygmomanometer, average BP was higher for wrist cuff (systolic = 4.8 mmHg and diastolic = 3.6 mmHg) and varied for arm cuff (systolic = −1.5 mmHg and diastolic = 2.5 mmHg). Calibration increased performance from grade B to A for arm cuff and from D to B for wrist cuff. Calibration increased false negatives and decreased false positives. Discussion: The arm HBPM device is more accurate than the wrist cuff among ANAIs with hypertension. Most patients are willing to use the arm cuff when accuracy is discussed.


Sign in / Sign up

Export Citation Format

Share Document