scholarly journals Interaction of Left Ventricular Size and Sex on Outcome of Cardiac Resynchronization Therapy Among Patients With a Narrow QRS Duration in the EchoCRT Trial

2018 ◽  
Vol 7 (12) ◽  
2011 ◽  
Vol 162 (4) ◽  
pp. 646-653 ◽  
Author(s):  
John Rickard ◽  
Danielle M. Brennan ◽  
David O. Martin ◽  
Eileen Hsich ◽  
W.H. Wilson Tang ◽  
...  

Circulation ◽  
2003 ◽  
Vol 107 (15) ◽  
pp. 1985-1990 ◽  
Author(s):  
Martin G. St John Sutton ◽  
Ted Plappert ◽  
William T. Abraham ◽  
Andrew L. Smith ◽  
David B. DeLurgio ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Gravellone ◽  
G Dell' Era ◽  
F De Vecchi ◽  
E Boggio ◽  
E Prenna ◽  
...  

Abstract Background Cardiac resynchronization therapy (CRT) is an established treatment for heart failure with reduced ejection fraction (HFrEF). However, one third of patients are “non responders”. Cathodic-anodal (CA) left ventricle (LV) capture is a multisite pacing occurring during CRT using both bipolar and quadripolar LV lead. It allows depolarization to arise simultaneously from the cathode and the anode of the bipole located on the LV epicardium, activating a larger volume of myocardium than cathodal pacing alone, thus potentially improving electromechanical synchrony (figure 1). We have previously proven that CA-LV stimulation is feasible and similar to bicathodic multipoint pacing (MPP) in terms of QRS wavefront activation. Purpose We aimed to evaluate both the acute intraprocedural haemodynamic and electrical effects of CA biventricular stimulation (CA-BS), comparing it with right-ventricle only pacing (Right Ventricle-Stimulation: RV-S), single-point CRT (Single Point-Biventricular Stimulation: SP-BS) and multipoint bicathodic biventricular stimulation (Multi Point-Biventricular Stimulation:MP-BS) in de novo CRT implants. Methods Ten patients candidates to CRT (LV ejection fraction ≤35% and left bundle branch block) received a quadripolar LV lead. Four pacing configurations were tested: RV-S, SP-BS, MP-BS and CA-BS, where cathode and the anode were the same electrodes used as cathodes in MP-BS. QRS duration by 12-lead ECG was defined as the time from the earliest ventricular deflection until the return to the isoelectric line. Haemodynamic assessment by radial artery catheterization using Pressure Recording Analytical Method processed the following parameters: dP/dT max (mmHg/msec), systolic arterial pressure (aPsys, mmHg), diastolic arterial pressure (aPdia, mmHg), mean arterial pressure (aPmean, mmHg), Cardiac Index (CI, l/min/m2), Stroke Volume Index (SVI, ml/min/m2). Results dP/dT max and aPmean increased significantly from RV-S to SP-BS (mean dP/dT max 0,82±0,28 versus 0,87±0,29 mmHg/msec, p=0,02; mean aPmean 89±19 versus 93±20 mmHg, p=0,01), but not from RV-S to MP-BS. Comparing RV-S to CA-BS, only aPmean exhibited a significant increase (mean aPmean 89±19 versus 92±20 mmHg, p=0,01). There were no haemodynamic differences between SP-BS, MP-BS and CA-BS. QRS duration reduced significantly from RV-S (167±10 msec) to each biventricular stimulation (135±14 msec, p=0,0002 for SP-BS; 130±17 msec, p=0,0001 for MP-BS; 129±18 msec, p=0,0002 for CA-BS) and from SP-BS to MP-BS and CA-BS (p=0,03 for both), whereas there were no difference comparing MP-BS and CA-BS. Conclusions CA-LV stimulation is not superior to single-point CRT in terms of acute haemodynamic performance, whereas it reduces the duration of ventricular electrical activation, showing an electrohaemodynamic mismatch. Long-term studies are needed to evaluate if acute electrical benefits of CA stimulation can predict chronic benefits, in terms of reverse cardiac remodelling. Cathodic-anodal left ventricular capture Funding Acknowledgement Type of funding source: None


Author(s):  
Phillip E Schrumpf ◽  
Michael Giudici ◽  
Deborah Paul ◽  
Roselyn Krupa ◽  
Cynthia Meirbachtol

Background: Cardiac resynchronization therapy has been shown to improve left ventricular performance in patients with left ventricular dysfunction and a left-sided interventricular conduction delay. This is performed by placing a pacing lead on the lateral left ventricular wall to stimulate the area normally stimulated by the left bundle branch. In patients with right bundle branch block (RBBB), pacing the right bundle branch could also result in resynchronization. Previous studies have shown that right ventricular outflow septal (RVOS) pacing does, in fact, utilize the native conduction system. Methods: 62 consecutive patients, 46 male/16 female, aged 75 +/− 10.5 yr, with RBBB and indications for pacing, underwent RVOS lead placement using commercially available pacing systems. The patients subsequently underwent bedside A-V optimization to achieve the narrowest QRS duration and most “normal” QRS complex. Echocardiography was performed to evaluate changes in wall motion comparing baseline with optimal pacing. Results: Baseline mean QRS duration 146 +/− 20.9 ms Optimized mean QRS duration 111 +/− 20.5 ms Average decrease in QRS duration -35 +/− 21.5 ms p < 0.001 Echocardiography demonstrated improvement in septal contraction abnormalities. Conclusions: 1) RVOS pacing in RBBB patients can significantly narrow the QRS complex on ECG. 2) Septal contraction abnormalities due to RBBB can be improved with RVOS pacing and optimal A-V timing. 3) Further studies are warranted to evaluate this therapy in a heart failure population.