biventricular stimulation
Recently Published Documents


TOTAL DOCUMENTS

41
(FIVE YEARS 2)

H-INDEX

8
(FIVE YEARS 0)

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Gravellone ◽  
G Dell' Era ◽  
F De Vecchi ◽  
E Boggio ◽  
E Prenna ◽  
...  

Abstract Background Cardiac resynchronization therapy (CRT) is an established treatment for heart failure with reduced ejection fraction (HFrEF). However, one third of patients are “non responders”. Cathodic-anodal (CA) left ventricle (LV) capture is a multisite pacing occurring during CRT using both bipolar and quadripolar LV lead. It allows depolarization to arise simultaneously from the cathode and the anode of the bipole located on the LV epicardium, activating a larger volume of myocardium than cathodal pacing alone, thus potentially improving electromechanical synchrony (figure 1). We have previously proven that CA-LV stimulation is feasible and similar to bicathodic multipoint pacing (MPP) in terms of QRS wavefront activation. Purpose We aimed to evaluate both the acute intraprocedural haemodynamic and electrical effects of CA biventricular stimulation (CA-BS), comparing it with right-ventricle only pacing (Right Ventricle-Stimulation: RV-S), single-point CRT (Single Point-Biventricular Stimulation: SP-BS) and multipoint bicathodic biventricular stimulation (Multi Point-Biventricular Stimulation:MP-BS) in de novo CRT implants. Methods Ten patients candidates to CRT (LV ejection fraction ≤35% and left bundle branch block) received a quadripolar LV lead. Four pacing configurations were tested: RV-S, SP-BS, MP-BS and CA-BS, where cathode and the anode were the same electrodes used as cathodes in MP-BS. QRS duration by 12-lead ECG was defined as the time from the earliest ventricular deflection until the return to the isoelectric line. Haemodynamic assessment by radial artery catheterization using Pressure Recording Analytical Method processed the following parameters: dP/dT max (mmHg/msec), systolic arterial pressure (aPsys, mmHg), diastolic arterial pressure (aPdia, mmHg), mean arterial pressure (aPmean, mmHg), Cardiac Index (CI, l/min/m2), Stroke Volume Index (SVI, ml/min/m2). Results dP/dT max and aPmean increased significantly from RV-S to SP-BS (mean dP/dT max 0,82±0,28 versus 0,87±0,29 mmHg/msec, p=0,02; mean aPmean 89±19 versus 93±20 mmHg, p=0,01), but not from RV-S to MP-BS. Comparing RV-S to CA-BS, only aPmean exhibited a significant increase (mean aPmean 89±19 versus 92±20 mmHg, p=0,01). There were no haemodynamic differences between SP-BS, MP-BS and CA-BS. QRS duration reduced significantly from RV-S (167±10 msec) to each biventricular stimulation (135±14 msec, p=0,0002 for SP-BS; 130±17 msec, p=0,0001 for MP-BS; 129±18 msec, p=0,0002 for CA-BS) and from SP-BS to MP-BS and CA-BS (p=0,03 for both), whereas there were no difference comparing MP-BS and CA-BS. Conclusions CA-LV stimulation is not superior to single-point CRT in terms of acute haemodynamic performance, whereas it reduces the duration of ventricular electrical activation, showing an electrohaemodynamic mismatch. Long-term studies are needed to evaluate if acute electrical benefits of CA stimulation can predict chronic benefits, in terms of reverse cardiac remodelling. Cathodic-anodal left ventricular capture Funding Acknowledgement Type of funding source: None


EP Europace ◽  
2018 ◽  
Vol 20 (suppl_1) ◽  
pp. i116-i116
Author(s):  
E Aversa ◽  
L M Delgado Elias ◽  
J C Jurado Grisales ◽  
N Lopez Cabanillas ◽  
B D Elencwajg ◽  
...  

2016 ◽  
Vol 67 (18) ◽  
pp. 2158-2160
Author(s):  
Frieder Braunschweig ◽  
Cecilia Linde

EP Europace ◽  
2013 ◽  
Vol 15 (10) ◽  
pp. 1491-1498 ◽  
Author(s):  
Michio Ogano ◽  
Yu-ki Iwasaki ◽  
Jun Tanabe ◽  
Hisato Takagi ◽  
Takuya Umemoto ◽  
...  

2011 ◽  
Vol 27 (Supplement) ◽  
pp. OP06_7
Author(s):  
Michio Ogano ◽  
Jun Tanabe ◽  
Hisato Takagi ◽  
Takuya Umemoto ◽  
Yu-Ki Iwasaki ◽  
...  

Heart Rhythm ◽  
2010 ◽  
Vol 7 (3) ◽  
pp. 344-350 ◽  
Author(s):  
Jean-Benoit Thambo ◽  
Pierre Dos Santos ◽  
Maxime De Guillebon ◽  
Francois Roubertie ◽  
Louis Labrousse ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document