scholarly journals Utility of icteric index in clinical laboratories: more than a preanalytical indicator

2021 ◽  
Vol 31 (2) ◽  
Author(s):  
Rufino Mondejar ◽  
María Mayor Reyes ◽  
Enrique Melguizo Madrid ◽  
Consuelo Cañavate Solano ◽  
Santiago Pérez Ramos
Author(s):  
J. N. Meador ◽  
C. N. Sun ◽  
H. J. White

The electron microscope is being utilized more and more in clinical laboratories for pathologic diagnosis. One of the major problems in the utilization of the electron microscope for diagnostic purposes is the time element involved. Recent experimentation with rapid embedding has shown that this long phase of the process can be greatly shortened. In rush cases the making of projection slides can be eliminated by taking dark field electron micrographs which show up as a positive ready for use. The major limiting factor for use of dark field micrographs is resolution. However, for conference purposes electron micrographs are usually taken at 2.500X to 8.000X. At these low magnifications the resolution obtained is quite acceptable.


1974 ◽  
Vol 13 (03) ◽  
pp. 151-158 ◽  
Author(s):  
D. A. B. Lindbebo ◽  
Fr. R. Watson

Recent studies suggest the determinations of clinical laboratories must be made more precise than at present. This paper presents a means of examining benefits of improvement in precision. To do this we use a mathematical model of the effect upon the diagnostic process of imprecision in measurements and the influence upon these two of Importance of Diagnosis and Prevalence of Disease. The interaction of these effects is grossly non-linear. There is therefore no proper intuitive answer to questions involving these matters. The effects can always, however, be calculated.Including a great many assumptions the modeling suggests that improvements in precision of any determination ought probably to be made in hospital rather than screening laboratories, unless Importance of Diagnosis is extremely high.


1991 ◽  
Vol 65 (02) ◽  
pp. 160-164 ◽  
Author(s):  
Marina Poggio ◽  
Armando Tripodi ◽  
Guglielmo Mariani ◽  
Pier Mannuccio Mannucci ◽  

SummaryBeing a putative predictor of ischemic heart disease, the measurement of factor VII (FVTI) coagulant activity will be presumably requested to clinical laboratories with increasing frequency. To assess the influence on FVII assays of different thromboplastins and FVII-deficient plasmas we compared performances of all possible combinations of 5 thromboplastins and 6 deficient plasmas. The reproducibility of the clotting times of the dose-response curves for human and rabbit thromboplastins were acceptable (CV lower than 7%), whereas bovine thromboplastin had a higher CV. Reproducibility was very similar for all deficient plasmas when they were used in combination with a given thromboplastin. Responsiveness of the dose-response curve did not depend on the deficient plasma but rather on the thromboplastin: one rabbit thromboplastin was the least responsive, the bovine thromboplastin the most responsive, the human and the remaining two rabbit thromboplastins had intermediate responsiveness. Assay sensitivity to cold-activated FVII varied according to the thromboplastin: the bovine thromboplastin was the most sensitive, the human thromboplastin the least sensitive, of the three rabbit thromboplastins two were relatively sensitive, one was almost insensitive. In conclusion, our results indicate that thromboplastin rather than deficient plasma is the crucial factor in the standardization of FVII assay.


2020 ◽  
Author(s):  
Christine L H Snozek ◽  
Leland B Baskin ◽  
Jessica M Boyd ◽  
Brian N Kelly ◽  
Matthew D Krasowski ◽  
...  

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Keivan Moradi ◽  
Aboozar Mohammadi ◽  
Mohsen Kazeminia

Abstract Background The quantification of hemoglobin A2 (Hb A2; α2δ2) is used as a valuable test to differentiate α- and ß-thal carriers in clinical laboratories. Therefore, the HBD (δ-globin) gene variants could result in reduced levels of Hb A2 and have implications for thalassemia screening programs. The aim of the present study was to predict the consequences of HBD gene variants identified in the Iranome project. Results The highest number of variants was in the Persian Gulf Islanders. The variants of p.Gln132Glu (HBD: c.394C>G), p.Gly17Arg (HBD: c.49G>C), p.Thr5Ile (HBD: c.14C>T), and p.Ala28Ser (HBD: c.82G>T) presented damage results in three or more prediction tools. In addition, it seems that the p.Gly30= (HBD: c.90C>T) decreases the use of authentic splice and, instead, creates a new donor splice site (DSS) or leads to the use of a cryptic DSS. Conclusions Most of these variants have been associated with a decrease in Hb A2 levels. Due to the high mutational diversity in the HBB gene in the Iranian population and the use of Hb A2 quantification to differentiate α- and ß-thal carriers among Iranian clinical laboratories, some attention should be taken to a possible co-inheritance of HBD gene variants to avoid the misdiagnosis of ß-thal carriers.


Author(s):  
Paul C. D. Bank ◽  
Leo H. J. Jacobs ◽  
Sjoerd A. A. van den Berg ◽  
Hanneke W. M. van Deutekom ◽  
Dörte Hamann ◽  
...  

AbstractThe in vitro diagnostic medical devices regulation (IVDR) will take effect in May 2022. This regulation has a large impact on both the manufacturers of in vitro diagnostic medical devices (IVD) and clinical laboratories. For clinical laboratories, the IVDR poses restrictions on the use of laboratory developed tests (LDTs). To provide a uniform interpretation of the IVDR for colleagues in clinical practice, the IVDR Task Force was created by the scientific societies of laboratory specialties in the Netherlands. A guidance document with explanations and interpretations of relevant passages of the IVDR was drafted to help laboratories prepare for the impact of this new legislation. Feedback from interested parties and stakeholders was collected and used to further improve the document. Here we would like to present our approach to our European colleagues and inform them about the impact of the IVDR and, importantly we would like to present potentially useful approaches to fulfill the requirements of the IVDR for LDTs.


Sign in / Sign up

Export Citation Format

Share Document