36. With A Minor Flaw

Living Japan ◽  
2009 ◽  
pp. 118-119
Keyword(s):  
2021 ◽  
Author(s):  
Murad Hussain

Telecommunication circuits and leased lines have been in use for controlling substations for many years. These circuits have usually been engineered according to set standards however recent studies have shown that the parameters used for engineering the telecommunication circuits have various design flaws that may put these circuits. in jeopardy during a local substation fault. The existing protection scheme for SolarI wind and other relevant power generating farms are such that if they lose communication with the local Utility Transmission Station (UTS)I the UTS automatically trips a local breaker and knocks the generation plant off the grid this could mean thousands of dollars in lost revenue for the generation company hence even a minor flaw in the telecommunication circuits can have a significant impact on the substation control system. This case study reviews the challenges of designing these telecommunication circuits for control and monitoring of substations and also reviews the case study performed by Hydro Quebec on the concept of Zone of Influence. In addition this study also proposes an alternate telecommunication model that when implemented will be able to withstand all the challenges of designing a circuits for the high voltage substation.


1998 ◽  
Vol 39 (4) ◽  
pp. 410-415 ◽  
Author(s):  
K. L. Hermann ◽  
N. Egund

Purpose: To describe a new method for measuring femoral neck anteversion (FNA) that requires only one lateral radiograph of the knee in addition to routine radiographs of the hip for evaluation of total hip replacement; and to compare the proposed method with FNA measurement by means of 3D CT. Material and Methods: In 18 femoral specimens, radiographic examinations of the hip and knee, in three different rotational positions, and one CT examination were made, and the measurements of FNA were compared. Similarly, in 38 patients with 40 total hip replacements, measurements from routine radiographic examinations of the hip and knee and from CT examinations were compared. The accuracy and reproducibility of the FNA measurements produced by this proposed method were calculated. Results: Accuracy and reproducibility were 2° and 2° for the proposed method in the femoral specimen study, and accuracy was 4° in the hip patient study. The proposed method had a minor flaw that was caused almost solely by differences in knee size at inward rotation of the femur. Conclusion: FNA measurement can be made from a routine radiographic examination of the hip and a lateral view of the knee. This method achieves an acceptable level of accuracy and reproducibility.


2021 ◽  
Author(s):  
Murad Hussain

Telecommunication circuits and leased lines have been in use for controlling substations for many years. These circuits have usually been engineered according to set standards however recent studies have shown that the parameters used for engineering the telecommunication circuits have various design flaws that may put these circuits. in jeopardy during a local substation fault. The existing protection scheme for SolarI wind and other relevant power generating farms are such that if they lose communication with the local Utility Transmission Station (UTS)I the UTS automatically trips a local breaker and knocks the generation plant off the grid this could mean thousands of dollars in lost revenue for the generation company hence even a minor flaw in the telecommunication circuits can have a significant impact on the substation control system. This case study reviews the challenges of designing these telecommunication circuits for control and monitoring of substations and also reviews the case study performed by Hydro Quebec on the concept of Zone of Influence. In addition this study also proposes an alternate telecommunication model that when implemented will be able to withstand all the challenges of designing a circuits for the high voltage substation.


1997 ◽  
Vol 2 (4) ◽  
pp. 1-3
Author(s):  
James B. Talmage

Abstract The AMA Guides to the Evaluation of Permanent Impairment, Fourth Edition, uses the Injury Model to rate impairment in people who have experienced back injuries. Injured individuals who have not required surgery can be rated using differentiators. Challenges arise when assessing patients whose injuries have been treated surgically before the patient is rated for impairment. This article discusses five of the most common situations: 1) What is the impairment rating for an individual who has had an injury resulting in sciatica and who has been treated surgically, either with chemonucleolysis or with discectomy? 2) What is the impairment rating for an individual who has a back strain and is operated on without reasonable indications? 3) What is the impairment rating of an individual with sciatica and a foot drop (major anterior tibialis weakness) from L5 root damage? 4) What is the rating for an individual who is injured, has true radiculopathy, undergoes a discectomy, and is rated as Category III but later has another injury and, ultimately, a second disc operation? 5) What is the impairment rating for an older individual who was asymptomatic until a minor strain-type injury but subsequently has neurogenic claudication with severe surgical spinal stenosis on MRI/myelography? [Continued in the September/October 1997 The Guides Newsletter]


2018 ◽  
Vol 23 (4) ◽  
pp. 9-10
Author(s):  
James Talmage ◽  
Jay Blaisdell

Abstract Pelvic fractures are relatively uncommon, and in workers’ compensation most pelvic fractures are the result of an acute, high-impact event such as a fall from a roof or an automobile collision. A person with osteoporosis may sustain a pelvic fracture from a lower-impact injury such as a minor fall. Further, major parts of the bladder, bowel, reproductive organs, nerves, and blood vessels pass through the pelvic ring, and traumatic pelvic fractures that result from a high-impact event often coincide with damaged organs, significant bleeding, and sensory and motor dysfunction. Following are the steps in the rating process: 1) assign the diagnosis and impairment class for the pelvis; 2) assign the functional history, physical examination, and clinical studies grade modifiers; and 3) apply the net adjustment formula. Because pelvic fractures are so uncommon, raters may be less familiar with the rating process for these types of injuries. The diagnosis-based methodology for rating pelvic fractures is consistent with the process used to rate other musculoskeletal impairments. Evaluators must base the rating on reliable data when the patient is at maximum medical impairment and must assess possible impairment from concomitant injuries.


Author(s):  
Katherine Guérard ◽  
Sébastien Tremblay

In serial memory for spatial information, some studies showed that recall performance suffers when the distance between successive locations increases relatively to the size of the display in which they are presented (the path length effect; e.g., Parmentier et al., 2005) but not when distance is increased by enlarging the size of the display (e.g., Smyth & Scholey, 1994). In the present study, we examined the effect of varying the absolute and relative distance between to-be-remembered items on memory for spatial information. We manipulated path length using small (15″) and large (64″) screens within the same design. In two experiments, we showed that distance was disruptive mainly when it is varied relatively to a fixed reference frame, though increasing the size of the display also had a small deleterious effect on recall. The insertion of a retention interval did not influence these effects, suggesting that rehearsal plays a minor role in mediating the effects of distance on serial spatial memory. We discuss the potential role of perceptual organization in light of the pattern of results.


1956 ◽  
Vol 1 (12) ◽  
pp. 366-367
Author(s):  
EPHRAIM ROSEN
Keyword(s):  

1978 ◽  
Vol 23 (5) ◽  
pp. 376-377 ◽  
Author(s):  
HENRI TAJFEL
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document