Constant or Adjustable Intensity of Electrical Current Does Not Elicit Different Level of Quadriceps Femoris Fatigue during Neuromuscular Electrical Stimulation Sessions in Patients with COPD.

Author(s):  
C Malaguti ◽  
RR Rondelli ◽  
JR Paz ◽  
LC Reis ◽  
S Dal Corso
2001 ◽  
Vol 81 (7) ◽  
pp. 1307-1316 ◽  
Author(s):  
Yocheved Laufer ◽  
Julie Deanne Ries ◽  
Peter M Leininger ◽  
Gad Alon

Abstract Background and Purpose. Neuromuscular electrical stimulation is used by physical therapists to improve muscle performance. Optimal forms of stimulation settings are yet to be determined, as are possible sex-related differences in responsiveness to electrical stimulation. The objectives of the study were: (1) to compare the ability of 3 different waveforms to generate isometric contractions of the quadriceps femoris muscles of individuals without known impairments, (2) to compare muscle fatigue caused by repeated contractions induced by these same waveforms, and (3) to examine the effect of sex on muscle force production and fatigue induced by electrical stimulation. Subjects. Fifteen women and 15 men (mean age=29.5 years, SD=5.4, range=22–38) participated in the study. Methods. A portable battery-operated stimulator was used to generate either a monophasic or biphasic rectangular waveform. A stimulator that was plugged into an electrical outlet was used to generate a 2,500-Hz alternating current. Phase duration, frequency, and on-off ratios were kept identical for both stimulators. Participants did not know the type of waveform being used. Torque was measured using a computerized dynamometer: a maximal voluntary isometric contraction (MVIC) of the right quadriceps femoris muscle set at 60 degrees of knee flexion was determined during the first session. In each of the 3 testing sessions, torque of contraction and fatigue elicited by one waveform were measured. Order of testing was randomized. Torque elicited by electrical stimulation was expressed as a percentage of average MVIC. A mixed-model analysis of variance was used to determine the effect of stimulation and sex on strength of contraction and fatigue. Bonferroni-corrected post hoc tests were used to further distinguish between the effects of the 3 stimulus waveforms. Results. The results indicated that the monophasic and biphasic waveforms generated contractions with greater torque than the polyphasic waveform. These 2 waveforms also were less fatiguing. The torques from the maximally tolerated electrically elicited contractions were greater for the male subjects than for the female subjects. Discussion and Conclusion. Muscle torque and fatigue of electrically induced contractions depend on the waveform used to stimulate the contraction, with monophasic and biphasic waveforms having an advantage over the polyphasic waveform. All tested waveforms elicited, on average, stronger contractions in male subjects than in female subjects when measured as a percentage of MVIC.


2018 ◽  
Vol 26 (5) ◽  
pp. 346-349
Author(s):  
Carlos Eduardo Pinfildi ◽  
Rodrigo Antonio Carvalho Andraus ◽  
Ligia Megumi Iida ◽  
Rodrigo Paschoal Prado

ABSTRACT Objective: The purpose of this study was to investigate the effects of neuromuscular electrical stimulation (NMES) in different frequencies on the quadriceps femoris. A randomized, controlled, blind cross-sectional study. Methods: Thirty subjects (12 men and 18 women), with an average age of 24.67 years, weight of 65.62 kg and height of 1.69 m were evaluated. Three random test conditions were applied: maximum voluntary isometric contraction (MVIC), maximum voluntary isometric contraction with medium frequency current (MVIC-MF) and maximum voluntary isometric contraction with low frequency current (MVIC-LF). Four MVICs were applied in each situation. The time between different isometric contraction types was 90 seconds while the time between the same conditions of contraction was 10 seconds. Results: Two-way ANOVA test showed that MVIC-MF had higher values for peak torque than MVIC-LF (p=0.02). Significant statistical results were found when comparing MVIC-MF and MVIC (p=0.03), but not for MVIC and MVIC-LF (p=0.52). Conclusion: Maximum voluntary isometric contraction associated with medium-frequency electrical stimulation was more effective than other NMES conditions. Level of Evidence II, Therapeutic Studies - Investigation of treatment results.


Critical Care ◽  
2019 ◽  
Vol 23 (1) ◽  
Author(s):  
Julius J. Grunow ◽  
Moritz Goll ◽  
Niklas M. Carbon ◽  
Max E. Liebl ◽  
Steffen Weber-Carstens ◽  
...  

Abstract Background Neuromuscular electrical stimulation (NMES) has been investigated as a preventative measure for intensive care unit-acquired weakness. Trial results remain contradictory and therefore inconclusive. As it has been shown that NMES does not necessarily lead to a contractile response, our aim was to characterise the response of critically ill patients to NMES and investigate potential outcome benefits of an adequate contractile response. Methods This is a sub-analysis of a randomised controlled trial investigating early muscle activating measures together with protocol-based physiotherapy in patients with a SOFA score ≥ 9 within the first 72 h after admission. Included patients received protocol-based physiotherapy twice daily for 20 min and NMES once daily for 20 min, bilaterally on eight muscle groups. Electrical current was increased up to 70 mA or until a contraction was detected visually or on palpation. Muscle strength was measured by a blinded assessor at the first adequate awakening and ICU discharge. Results One thousand eight hundred twenty-four neuromuscular electrical stimulations in 21 patients starting on day 3.0 (2.0/6.0) after ICU admission were included in this sub-analysis. Contractile response decreased from 64.4% on day 1 to 25.0% on day 7 with a significantly lower response rate in the lower extremities and proximal muscle groups. The electrical current required to elicit a contraction did not change over time (day 1, 50.2 [31.3/58.8] mA; day 7, 45.3 [38.0/57.5] mA). The electrical current necessary for a contractile response was higher in the lower extremities. At the first awakening, patients presented with significant weakness (3.2 [2.5/3.8] MRC score). When dividing the cohort into responders and non-responders (> 50% vs. ≤ 50% contractile response), we observed a significantly higher SOFA score in non-responders. The electrical current necessary for a muscle contraction in responders was significantly lower (38.0 [32.8/42.9] vs. 54.7 [51.3/56.0] mA, p < 0.001). Muscle strength showed higher values in the upper extremities of responders at ICU discharge (4.4 [4.1/4.6] vs. 3.3 [2.8/3.8] MRC score, p = 0.036). Conclusion Patients show a differential contractile response to NMES, which appears to be dependent on the severity of illness and also relevant for potential outcome benefits. Trial registration ISRCTN ISRCTN19392591, registered 17 February 2011


Sign in / Sign up

Export Citation Format

Share Document