Giant Magneto-Impedance (GMI) Effect in Single-Layer Soft Magnetic Film Under Stress

2018 ◽  
Vol 18 (12) ◽  
pp. 8195-8200 ◽  
Author(s):  
L Zhu ◽  
F Jin ◽  
Y. Q Zhu ◽  
J. C Wang ◽  
K. F Dong ◽  
...  

The stress-induced magnetic anisotropy can significantly affect giant magneto-impedance (GMI) effect of the soft magnetic film. This paper is devoted to the GMI effect of the single layer soft magnetic film implied without and with a stress. By simulating a physical model with MATLAB and COMSOL software, the impedance expression of the single layer soft magnetic film and the relation between external magnetic field and magnetic permeability are deduced. We observed that, without a stress, the sensitive region increased firstly and then decreased with the increasing of the excitation current frequency from 1 MHz to 200 MHz. While the film was subjected to the stress in the direction of the current with one end stressed, the stress on the film was gradually reduced from stressed end to free end. Also, the impedance change rate of the film changed when the stress was added, which is similar to the effect of adding a bias magnetic field on the film. More importantly, the addition of stress σ can induce the bias of the GMI measurement range and improve its sensitivity near zero magnetic fields. This may provide a new way for designing a GMI sensor with higher sensitivity and adjustable measurement range.

2003 ◽  
Vol 93 (10) ◽  
pp. 8588-8590 ◽  
Author(s):  
Ki Hyeon Kim ◽  
Shinji Ikeda ◽  
Masahiro Yamaguchi ◽  
Ken-Ichi Arai

2011 ◽  
Vol 284-286 ◽  
pp. 2303-2306
Author(s):  
Su Qin Feng ◽  
Yin Feng Li ◽  
Jian Yong Wang ◽  
Chun Hui Feng ◽  
Shuang Yi Zhao ◽  
...  

In order to obtain materials with more ideal GMI effect, (DZ/Z)max, the substitution effects of R (R = Co, Ni and Cr) for Fe in Fe63.5R10Cu1Nb3Si13.5B9soft magnetic wires have been studied. We found that although the Finemet composition shown excellent GMI effect, the substitution of Co can raise notably the field sensitivity, Q, Ni makes a little improvements of (DZ/Z)max, and Q, and Cr diminishes the undesirable hysteretic effect. In additions, the influence of annealing conditions upon the GMI effect of the best composition Fe63.5Cr10Cu1Nb3Si13.5B9was also investigated. It indicated that the sample obtained by the ways of Joule heating under the application of suitable tensile stress exhibits 200% and 30%¤Oe for (DZ/Z)max and Q, respectively. This sample can serve as a proper choice for magnetic sensors.


2012 ◽  
Vol 6 (1) ◽  
pp. 39-43 ◽  
Author(s):  
A. Zhukov ◽  
M. Ipatov ◽  
J. M. Blanco ◽  
V. Zhukova

In this paper we experimentally studied GMI effect and soft magnetic behavior of Co-rich microwires. Correlation between magnetoelastic anisotropy and magnetic field dependences of diagonal and off-diagonal impedance components are observed. Low field GMI hysteresis, explained in terms of magnetoelastic anisotropy of microwires, has been suppressed by the bias current.


2014 ◽  
Vol 926-930 ◽  
pp. 137-140
Author(s):  
Jie Li ◽  
Xin Hua Lin ◽  
Xiao Hua Wang ◽  
Min Tang

Co64Fe4Si14.5B14.5amorphous ribbon was fabricated by the melt-spinning technique. Soft magnetic properties of the ribbon were improved by annealing at 623K for 1 hour with a zero magnetic field, a 50mT longitudinal or transverse external magnetic field comparing with the as-quenched ribbon. The longitudinally driven giant magneto-impedance (LDGMI) effect and its field sensitivity (ξ) have been investigated in the frequency (f) range of 1kHz~1MHz. It is found that at f=51kHz, the LDGMI effect and ξ reach the largest values for the sample annealed with a longitudinal magnetic field.


2014 ◽  
Vol 556-562 ◽  
pp. 4880-4883
Author(s):  
Jing Xiao ◽  
Xiu Sheng Duan ◽  
Zhe Feng

As magnetic field varies greatly under complex environment, it is difficult for GMI sensor to adapt. On basis of analyzing the curve of GMI effect, curve fitting methods with polynomial, sum of sine functions and the BP neural network are studied to find the best one to fit the sensors’ outputs. When the best one is acted as model of the GMI sensor for measurement, the measurement precision can be effectively improved and the sensors' range can be greatly expanded.


Sign in / Sign up

Export Citation Format

Share Document