scholarly journals The Impact of Retardance Pattern Variability on Nerve Fiber Layer Measurements over Time Using GDx with Variable and Enhanced Corneal Compensation

2011 ◽  
Vol 52 (7) ◽  
pp. 4516 ◽  
Author(s):  
Dilraj S. Grewal ◽  
Mitra Sehi ◽  
Richard J. Cook ◽  
David S. Greenfield
2019 ◽  
Vol 28 (5) ◽  
pp. 368-374 ◽  
Author(s):  
Nisha Nagarkatti-Gude ◽  
Stuart K. Gardiner ◽  
Brad Fortune ◽  
Shaban Demirel ◽  
Steven L. Mansberger

2021 ◽  
Vol 4 (11) ◽  
pp. e2134753
Author(s):  
Frank C. T. van der Heide ◽  
Indra L. M. Steens ◽  
Anouk F. J. Geraets ◽  
Yuri D. Foreman ◽  
Ronald M. A. Henry ◽  
...  

2020 ◽  
Vol 97 (2) ◽  
pp. 54-61 ◽  
Author(s):  
Brett J. King ◽  
William H. Swanson ◽  
Stephanie A. Klemencic ◽  
Michael Chaglasian ◽  
Bruce A. Teitelbaum ◽  
...  

2015 ◽  
Vol 2015 ◽  
pp. 1-6
Author(s):  
Mirian Ara ◽  
Antonio Ferreras ◽  
Ana B. Pajarin ◽  
Pilar Calvo ◽  
Michele Figus ◽  
...  

Objective. To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes.Methods. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups.Results. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84.Conclusions. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.


Sign in / Sign up

Export Citation Format

Share Document