scholarly journals Design of alternating current voltage–regulating circuit based on thyristor: Comparison of single phase and three phase

2020 ◽  
Vol 53 (5-6) ◽  
pp. 884-891
Author(s):  
Zonglu Zhang

The voltage sag problem in a power grid can be solved by a voltage regulator. In this study, the voltage regulator based on thyristor was used to compensate the single-phase and three-phase voltage of voltage sag fault, so as to recover the normal level of voltage. The simulation analysis was carried out on MATLAB. The results showed that voltage sag faults mainly affected the amplitude of voltage, but not the frequency of voltage. After voltage regulation, the single-phase and three-phase voltage waveforms in the fault period had a certain recovery, but the voltage regulator had a certain hysteresis effect.

Author(s):  
Igor A. Pires ◽  
Felipe Dias de Oliveira ◽  
Sidelmo M. Silva ◽  
Braz De J. Cardoso Filho

2017 ◽  
Vol 53 (1) ◽  
pp. 630-637 ◽  
Author(s):  
Igor Amariz Pires ◽  
Filipe Dias de Oliveira ◽  
Sidelmo Magalhaes Silva ◽  
Braz de Jesus Cardoso Filho

Author(s):  
Renukadevi S ◽  
Rathinakumar M

<p>This Paper compares the sensitivity of various adjustable speed drives to voltage sag for the process control applications. Three phase voltage sag of type B caused due to SLG fault is considered and four topologies of ASD’s are compared in this paper. The comparison is done especially in speed, voltage, current and torque of the ASDs. Diode rectifier without z source inverter, diode rectifier with z source inverter , single phase two leg Vienna rectifier and single phase neutral linked Vienna with z source inverter are compared and the best one is highlighted. The circuits of various ASD’s are simulated using   Matlab /Simulink. </p>


2012 ◽  
Vol 433-440 ◽  
pp. 7261-7266
Author(s):  
Hui Zhi Zhang ◽  
Yong Li Li ◽  
Bo Tong Li ◽  
Shuo Zhang ◽  
Zhen Tan

Voltage sag is one of the most frequent and serious dynamic problems that impact the power quality. To solve this problem, fast and precise detection of the voltage sag is needed. A detection method is presented in this paper, using single phase voltage information, to be applied in the typical condition of unsymmetrical three-phase voltage sag. This method adopts fast recognition of voltage disturbance and SPLL. Finally, MATLAB simulation has been used to verify the effectiveness of the method.


2015 ◽  
Vol 135 (3) ◽  
pp. 168-180 ◽  
Author(s):  
Ryota Mizutani ◽  
Hirotaka Koizumi ◽  
Kentaro Hirose ◽  
Kazunari Ishibashi

Author(s):  
Luo Xiaohui

This paper proposed a low cost wireless monitoring system based on ZigBee wireless transmission, and designed a new floating voltage sensor which is suitable for the monitoring of medium voltage and high voltage(MV/HV) public equipment. The system used TI-CC2530 as the controller, proposed a new moving average voltage sensing(MAVS) algorithm by reasonable assumptions, and adopted algorithms to perform the theoretical analysis for the single phase and three-phase voltage. At last, the author carried out a practical experiment on the wireless floating voltage sensor under the voltage up to 30kV, the experimental results showed that the proposed low cost wireless sensor can achieve a good voltage monitoring function, and the error is less than 3%.


Sign in / Sign up

Export Citation Format

Share Document