scholarly journals The Stroke Assessment of Fall Risk (SAFR): predictive validity in inpatient stroke rehabilitation

2014 ◽  
Vol 28 (12) ◽  
pp. 1218-1224 ◽  
Author(s):  
Terry P Breisinger ◽  
Elizabeth R Skidmore ◽  
Christian Niyonkuru ◽  
Lauren Terhorst ◽  
Grace B Campbell

Objective: To evaluate relative accuracy of a newly developed Stroke Assessment of Fall Risk (SAFR) for classifying fallers and non-fallers, compared with a health system fall risk screening tool, the Fall Harm Risk Screen. Design and setting: Prospective quality improvement study conducted at an inpatient stroke rehabilitation unit at a large urban university hospital. Participants: Patients admitted for inpatient stroke rehabilitation ( N = 419) with imaging or clinical evidence of ischemic or hemorrhagic stroke, between 1 August 2009 and 31 July 2010. Interventions: Not applicable. Main outcome measure(s): Sensitivity, specificity, and area under the curve for Receiver Operating Characteristic Curves of both scales’ classifications, based on fall risk score completed upon admission to inpatient stroke rehabilitation. Results: A total of 68 (16%) participants fell at least once. The SAFR was significantly more accurate than the Fall Harm Risk Screen ( p < 0.001), with area under the curve of 0.73, positive predictive value of 0.29, and negative predictive value of 0.94. For the Fall Harm Risk Screen, area under the curve was 0.56, positive predictive value was 0.19, and negative predictive value was 0.86. Sensitivity and specificity of the SAFR (0.78 and 0.63, respectively) was higher than the Fall Harm Risk Screen (0.57 and 0.48, respectively). Conclusions: An evidence-derived, population-specific fall risk assessment may more accurately predict fallers than a general fall risk screen for stroke rehabilitation patients. While the SAFR improves upon the accuracy of a general assessment tool, additional refinement may be warranted.

2020 ◽  
Vol 93 (1111) ◽  
pp. 20190923
Author(s):  
Xin Li ◽  
Feng Gao ◽  
Fan Li ◽  
Xiao-xia Han ◽  
Si-hui Shao ◽  
...  

Objective: To evaluate the performance of contrast-enhanced ultrasound in the diagnosis of small, solid, TR3–5 benign and malignant thyroid nodules (≤1 cm). Methods: From January 2016 to March 2018, 185 thyroid nodules from 154 patients who underwent contrast enhanced ultrasound (CEUS) and fine-needle aspiration or thyroidectomy in Shanghai General Hospital were included. The χ2 test was used to compare the CEUS characteristics of benign and malignant thyroid nodules, and the CEUS features of malignant nodules assigned scores. The total score of the CEUS features and the scores of the above nodules were evaluated according to the latest 2017 version of the Thyroid Imaging Reporting and Data System (TI-RADS). The diagnostic performance of the two were compared based on the receiver operating characteristic curves generated for benign and malignant thyroid nodules. Results: The degree, enhancement patterns, boundary, shape, and homogeneity of enhancement in thyroid small solid nodules were significantly different (p<0.05). No significant differences were seen between benign and malignant thyroid nodules regarding completeness of enhancement and size of enhanced lesions (p>0.05). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the TI-RADS classification TR5 in diagnosis of malignant nodules were 90.10%, 55.95%, 74.59%, 72.22%, and 82.46%, respectively (area under the curve [AUC]=0.738; 95% confidence interval[CI], 0.663–0.813). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the total score of CEUS qualitative analysis indicators were 86.13%, 89.29%, 87.57%, 90.63%, and 84.27% respectively (AUC = 0.916; 95% CI, 0.871–0.961). Conclusion: CEUS qualitative analysis is superior to TI-RADS in evaluating the diagnostic performance of small, solid thyroid nodules. Qualitative analysis of CEUS has a significantly higher specificity for diagnosis of malignant thyroid nodules than TI-RADS. Advances in knowledge: The 2017 version of TI-RADS has recently suggested the malignant stratification of thyroid nodules by ultrasound. In this paper we applied this system and CEUS to evaluate 185 nodules and compare the results with pathological findings to access the diagnostic performance.


Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 503
Author(s):  
Thomas F. Monaghan ◽  
Syed N. Rahman ◽  
Christina W. Agudelo ◽  
Alan J. Wein ◽  
Jason M. Lazar ◽  
...  

Sensitivity, which denotes the proportion of subjects correctly given a positive assignment out of all subjects who are actually positive for the outcome, indicates how well a test can classify subjects who truly have the outcome of interest. Specificity, which denotes the proportion of subjects correctly given a negative assignment out of all subjects who are actually negative for the outcome, indicates how well a test can classify subjects who truly do not have the outcome of interest. Positive predictive value reflects the proportion of subjects with a positive test result who truly have the outcome of interest. Negative predictive value reflects the proportion of subjects with a negative test result who truly do not have the outcome of interest. Sensitivity and specificity are inversely related, wherein one increases as the other decreases, but are generally considered stable for a given test, whereas positive and negative predictive values do inherently vary with pre-test probability (e.g., changes in population disease prevalence). This article will further detail the concepts of sensitivity, specificity, and predictive values using a recent real-world example from the medical literature.


2019 ◽  
Vol 3 (s1) ◽  
pp. 38-38
Author(s):  
Safa Kaleem ◽  
Christa B. Swisher

OBJECTIVES/SPECIFIC AIMS: 1. Determine positive predictive value, negative predictive value, sensitivity, and specificity of Neuro ICU nurse interpretation of real-time bedside qEEG. 2. Determine difference in time to detection of first seizure between Neuro ICU nurse qEEG interpretation and EEG fellow reads of cEEG. 3. Determine what qualities of seizures make detection by neuro ICU nurses more or less likely – e.g. duration of seizures, type of seizures, spatial extent of seizures. METHODS/STUDY POPULATION: Recruit neuro ICU nurses taking care of 150 patients admitted to the Neuro ICU at Duke University Hospital who are initiated on cEEG monitoring. Nurses will be consented for their participation in the study. Neuro ICU nurses will evaluate the qEE RESULTS/ANTICIPATED RESULTS: From literature estimates of a 20% seizure prevalence in critical care settings, we hope to have 30 patients with seizures and 120 without. Based on prior study in the Duke Neuro ICU, we hypothesize that Neuro ICU nurses will have sensitivity and DISCUSSION/SIGNIFICANCE OF IMPACT: This is the first prospective study of neuro ICU nurse interpretation of real-time bedside qEEG in patients with unknown NCSE/NCS presence. If nurse sensitivity, specificity, and positive predictive value are clinically useful, which we deem would be so at a sensitivity of 70% or greater, with acceptable false alarm rate, nurse readings of qEEG could significantly decrease the time to treatment of seizures in the Neuro ICU patient population, and perhaps could improve patient outcomes.


2021 ◽  
Vol 10 (1) ◽  
pp. 20-25
Author(s):  
Sujan Shrestha ◽  
Mamen Prasad Gorhaly ◽  
Manil Ratna Bajracharya

Background Diabetic peripheral neuropathy (DPN) is a significant independent risk factor for diabetic foot, and an effective screening instrument is required to diagnose DPN early to prevent future ulceration and amputation. This study aims to determine the diagnostic accuracy of monofilament test to detect diabetic peripheral neuropathy. Methods This cross-sectional study was conducted in National Academy of Medical Sciences, Bir hospital, Mahabouddha, Kathmandu from February 2016 to January 2017. A total of 96 diabetic patients attending inpatient and outpatient Department were selected. Diabetic peripheral neuropathy was assessed by measurement of loss of protective sensation (LOPS) by monofilament test and compared with vibration perception threshold by standard biothesiometer. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were calculated. Results The prevalence of diabetic peripheral neuropathy was 26%. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were found to be 92.0%, 95.8%, 88.5% and 97.1% respectively. There was strong association between LOPS by monofilament and vibration perception threshold by biothesiometer. Conclusion This study showed a strong diagnostic accuracy of monofilament test to detect DPN when compared with biothesiometer. As monofilament test is a cheap, easily available, and portable, it can be used in the periphery where biothesiometer is not available.  


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Tahir Iqbal ◽  
Muhammad Usman Shahid ◽  
Ishfaq Ahmad Shad ◽  
Shahzad Karim Bhatti ◽  
Syed Amir Gilani ◽  
...  

ABSTRACT: BACKGROUND: A common surgical emergency is acute appendicitis. Various diagnostic tools are available to diagnosis acute appendicitis. Radiological investigations play an important role in making accurate and early diagnosis and thus preventing morbidity associated with the disease. OBJECTIVE: To determine the diagnostic accuracy of gray scale ultrasonography versus color Doppler in suspected cases of acute appendicitis. MATERIALS AND METHODS: The study was carried in the department of Radiology of Mayo Hospital, Lahore. A total of 75 patients were enrolled of age 18-40 years, both genders who were suspected cases of acute appendicitis. All patients underwent baseline investigations along with gray scale ultrasonography and color Doppler. All patients were subjected to surgery to confirm the diagnosis and findings were subjected to statistical analysis. RESULTS: The mean age of the patients was 23.25 ±10.55 and mean transverse diameter of appendix was 8.37 ±3.39. There were 62.7% males and 37.3%females. Findings of gray scale ultrasonography and color Doppler were then correlated with surgical findings to calculate the diagnostic accuracy of these modalities. The results revealed that gray scale ultrasonography sensitivity, specificity, positive predictive value, negative predictive value and accuracy was 92.7%, 94.32%, 95%, 91.4% and 93.3% respectively, whereas color Doppler had sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 97.7%, 93.9%, 95.3%, 97% and 96% respectively. Diagnostic accuracy of both modalities together was 98.6%. CONCLUSION: Color Doppler has better diagnostic accuracy than gray scale ultrasonography for diagnosis of acute appendicitis and the combination of both modalities yields diagnostic accuracy that is similar to gold standard.


Author(s):  
Badugu Rao Bahadur ◽  
Gangadhara Rao Koneru ◽  
Prabha Devi Kodey ◽  
Jyothi Melam

Background: To differentiate ovarian mass as benign or malignant could change clinical approach. Finding a screening and diagnostic method for ovarian cancer is challenging due to high mortality and insidious symptoms. Risk malignancy index (RMI) has the advantage of rapid and exact triage of patients with ovarian mass.Methods: Prospective study carried for 2 years at NRI Medical College and General Hospital, Chinakakani, Mangalagiri, Andhra Pradesh, India. 79 patients with ovarian mass were investigated and risk malignancy index (RMI-3 and RMI-4) calculated. Final confirmation was done based on histopathological report. Sensitivity, specificity, positive predictive value and negative predictive value were calculated for RMI 3 and RMI 4 taking histopathology as control and comparison was done.Results: (n=79); 50 (63.29%) cases were benign and 29 (36.70%) were malignant based on histopathology. RMI 4 is more sensitive (68.96%) than RMI 3 (62.06%), but RMI 3 is more specific (94%) than RMI 4 (92%).The positive predictive value of RMI-3 and RMI-4 were 85.71%  and 83.33% respectively. The negative predictive value for RMI-4 and RMI-3 were 83.63% and 81.03% respectively.Conclusions: With increasing age, chance of malignancy increases. RMI 4 was more sensitive than RMI-3, however less specific than RMI 3 in differentiating benign and malignant tumors. The positive predictive value is slightly more for RMI 3, than RMI 4. Negative predictive value is slightly more for RMI 4, than RMI 3. 


2017 ◽  
Author(s):  
Ευστάθιος Δράμπαλος

Σκοπός: H εφαρμογή για πρώτη φορά διεθνώς της μορφομετρίας της σπονδυλικής στήλης με χρήση απορροφησιομετρίας (VFA) σε ασθενείς με κυφοπλαστική. Αναλύονται τα πλεονεκτήματα και μειονεκτήματα της μεθόδου, ελέγχεται η αξιοπιστία της και συγκρίνεται με την μορφομετρία κατά τον κλασσικό ακτινολογικό έλεγχο (ΜRΧ) στην εκτίμηση των σπονδυλικών παραμορφώσεων στους συγκεκριμένους ασθενείς.Υλικά και Μέθοδος: Πραγματοποιήθηκαν μετρήσεις σε 42 ασθενείς με κυφοπλαστική λόγω οστεοπορωτικών σπονδυλικών καταγμάτων και αναλύθηκαν οι σπόνδυλοι από τον T4 μέχρι τον L4 με την VFA και την MRX. Μετρήθηκαν το πρόσθιο (ha), μέσο (hm) και οπίσθιο (hp) ύψος του σπονδυλικού σώματος και προσδιορίσθηκαν οι λόγοι ha/hp και hm/hp. Αναλύθηκαν για την VFA η συμφωνία αποτελεσμάτων του ίδιου παρατηρητή (IOA) και η συμφωνία αποτελεσμάτων μεταξύ ανεξάρτητων παρατηρητών (INA) για τους λόγους ha/hp και hm/hp καθώς και για την μέθοδο Genant σε επίπεδο σπονδύλου, ‘περιοχής της σπονδυλικής στήλης (θωρακική/ΘΜΣΣ ή οσφυϊκή/ΟΜΣΣ), σε επίπεδο ‘γειτονικών προς την κυφοπλαστική σπονδύλων’, και σε επίπεδο ‘σπονδύλων με κυφοπλαστική’. Σε κάθε επίπεδο χρησιμοποιήθηκε η μέση τιμή ha/hp και hm/hp. Στη συνέχεια, αναλύσαμε την συμφωνία μεταξύ VFA και MRX στον καθορισμό των λόγων ha/hp και hm/hp καθώς και μετά την διχοτόμηση των λόγων ha/hp περί της τιμής όριο που συνήθως χρησιμοποιείται για τον καθορισμό ενός κατάγματος. Αποτελέσματα: Οι IOA και INA για τους λόγους ha/hp και hm/hp στην VFA ήταν ‘σχεδόν τέλεια’ σε όλα τα επίπεδα (ICC 0.94-0.98). Η εφαρμογή της μεθόδου Genant κατά την VFA ανέδειξε επίσης ‘σχεδόν τέλεια’ INA (ICC=0.833). Η ανάλυση σε επίπεδο σπονδύλου έδειξε ‘σχεδόν τέλεια’ συμφωνία μεταξύ VFA και MRX για τον λόγο ha/hp [intraclass correlation coefficient, ICC=0.85], και ‘ισχυρή συμφωνία’ για τον λόγο hm/hp (ICC=0.78). Για τον λόγο ha/hp η συμφωνία ήταν ‘σχεδόν τέλεια’ τόσο στην ΘΜΣΣ (ICC=0.82) όσο και στην ΟΜΣΣ (ICC=0.87), ενώ για τον λόγο hm/hp η συμφωνία ήταν ‘ισχυρή’ στην ΘΜΣΣ (ICC=0.75) και ‘σχεδόν τέλεια’ στην ΟΜΣΣ (ICC=0.80). Η συμφωνία ήταν εξίσου ‘σχεδόν τέλεια’ σε επίπεδο ‘σπονδύλων με κυφοπλαστική’ (ICC=0.83) όσο και σε επίπεδο ‘γειτονικών προς την κυφοπλαστική σπονδύλων’ (ICC=0.80) για τον λόγο ha/hp. Όταν οι λόγοι ha/hp μετατράπηκαν σε κατάγματα (ναι ή όχι κάταγμα) χρησιμοποιώντας διαφορετικές τιμές κατώφλι για την διάγνωση κατάγματος (λόγοι ha/hp 0.75, 0.80 και 0.85) η συμφωνία μεταξύ των μεθόδων ήταν λιγότερο καλή, από μέτρια έως ουσιώδης (κ 0.52-0.63 στην ΟΜΣΣ και 0.53-0.66 στην ΘΜΣΣ). Χρησιμοποιώντας την κατάταξη Genant οι διαφορές στην ταξινόμηση των σπονδύλων ήταν περισσότερο προς την κατεύθυνση της MRX με 32 αναγνωρισμένα κατάγματα μόνο από την MRX και μόνο 5 μόνο από την VFA. Στη μελέτη αυτή, με επιπολασμό σφηνοειδών σπονδυλικών καταγμάτων 9.3%, οι δείκτες ακρίβειας sensitivity, specificity, positive predictive value (PPV) και negative predictive value (NPV) υπολογίστηκαν σε 0.522, 0.97, 0.87 και 0.92 αντίστοιχα. Συμπεράσματα: Η εφαρμογή της VFA σε ασθενείς με κυφοπλαστική έχει υψηλή επαναληψιμότητα και αναπαραγωγιμότητα. Η συμφωνία μεταξύ VFA και MRX στην εκτίμηση των λόγων ha/hp και hm/hm ήταν από ‘ισχυρή’ έως ‘σχεδόν τέλεια’ ανάλογα με το επίπεδο εξέτασης. Η συμφωνία στην αναγνώριση των σπονδυλικών καταγμάτων ήταν μέτρια. Οι διαφορές ήταν περισσότερο προς την κατεύθυνση της MRX. Η υψηλή τιμή του δείκτη NPV της VFA στους ασθενείς με κυφοπλαστική, δείχνει ότι η μέθοδος θα μπορούσε να χρησιμοποιηθεί για τον εντοπισμό αυτών που χρήζουν περαιτέρω ακτινολογικού ελέγχου.


Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Yoon Juneyoung ◽  
Xiongjie Jin ◽  
Kyong-Woo Seo ◽  
Jin-sun Park ◽  
Hyoung-Mo Yang ◽  
...  

Introduction: The pressure gradient of the circulation fluid in a stenosis area depends on minimal luminal area (MLA) of the stenosis, lesion length (LL), and the fluid velocity. However, the correlation of the LL and the MLA; the cutoff values are uncertain. Hypothesis: LL and MLA differently influences the FFR. Methods: We studied 117 patients with intermediate coronary artery disease who underwent FFR and IVUS measurement out of 302 patients in FAVOR study. This study was a prospective, 1:1 randomized, open label multicenter trial to demonstrate the clinical outcomes between FFR and IVUS-guided PCI. Inclusion criteria were as follows: 1)Angina or documented silent ischemia 2) De novo intermediate coronary artery disease (30-70% diameter stenosis) by visual estimation, 3) Reference vessel diameter ≥ 3.0mm by visual estimation. We excluded left main disease, MI, EF< 40%, and graft vessel. There were no significant differences in baseline clinical characteristics. The mean values are the QCA (54.3±14.0 %), MLA (3.6±1.4 mm2) and LL (20.6±1.4mm), respectively. We were performed the path analysis using AMOS 18, and estimated the ROC curve in SPSS 18. Results: Standardized estimates were the LL -0.47,QCA -0.28 and MLA -0.21 (R2=0.594, p<0.000) in path analysis. The model is recursive and statistically significant. The FFR was ≤0.80 in 47 lesions (31%). The optimal LL for an FFR of ≤0.80 was 15.8mm (90% sensitivity, 50% specificity, 44% positive predictive value, 87% negative predictive value, area under the curve: 0.75, 95% CI: 0.66 to 0.85; p < 0.001) and MLA 3.9mm (sensitivity 86%, specificity 59%, 35% positive predictive value , 94% negative predictive value, area under the curve: 0.78, 95% CI: 0.67 to 0.85; p < 0.001) Conclusions: The lesion length influenced more the FFR than MLA. The lesion length ≥ 15.8mm and MLA ≤ 3.9mm are risk zones, which need to be confirm the functional status with FFR because of the low positive predictive value


2020 ◽  
Author(s):  
Bei Zhang ◽  
Li Zhang ◽  
Bingyang Bian ◽  
Fang Lin ◽  
Zining Zhu ◽  
...  

Abstract BACKGROUND Whole body diffusion weighted imaging (WB-DWI) is commonly used for the detection of multiple myeloma (MM). Comparative data on the efficiency of WB-DWI compared with 18 F positron emission tomography computed tomography ( 18 F-FDG PET/CT) to detect MM are lacking. METHODS This was a retrospective, single-center study of twenty-two patients with MM enrolled from January 2019 to December 2019. All patients underwent WB-DWI and 18 F-FDG PET/CT. Pathological and clinical manifestations as well as radiologic follow-up were used for diagnosis. The overall accuracy, sensitivity, specificity, positive predictive value and negative predictive value of both methods were compared. The appearance diffusion coefficient (ADC) values of MM lesions and false-positive lesions were estimated. RESULTS A total of 214 MM bone lesions were evaluated. WB-DWI showed a higher overall accuracy than PET/CT (75.7% and 55.6%, respectively; < 0.05). However, for sensitivity, specificity, positive predictive value and negative predictive value, there were no significant differences for WB-DWI vs PET/CT (99.3% and 83.9%, 64.9% and 94.8%, 63.6% and 54.2%, 98.1% and 65.3%, respectively). The ADC value for MM lesions was significantly lower than that for false-positive lesions (p < 0.001). Receiver operating curve (ROC) curve analysis showed that the AUC was 0.846, and when the cut-off value was 0.745×10 -3 mm 2 /s, the sensitivity and specificity were 86.0% and 82.4%, respectively, which distinguished MM lesions from non-MM lesions. CONCLUSION WB-DWI may be a useful tool for the diagnosis of MM bone disease due to to higher overall accuracy and measurements of ADC values compared with PET/CT.


Sign in / Sign up

Export Citation Format

Share Document