scholarly journals Mid-term outcomes of uncemented or cemented arthroplasty revision following metal-on-metal total hip arthroplasty failure: a retrospective observational study

2020 ◽  
Vol 48 (6) ◽  
pp. 030006052093205 ◽  
Author(s):  
Zhao Chen ◽  
Wenli Chen ◽  
Weiguang Yu ◽  
Mingdong Zhao ◽  
Jinluan lin ◽  
...  

Objective To retrospectively compare the mid-term outcomes of uncemented or cemented total hip arthroplasty (THA) revision for prior primary metal-on-metal (MoM) THA failure. Methods Data from 278 patients (278 hips) who underwent uncemented THA (UTHA) or cemented THA (CTHA) for prior primary MoM-THA failure from 2006 to 2016 were retrospectively analysed. Follow-up was performed 6 months, 1 year, 2 years, and then every 2 years after conversion. The mean follow-up time was 96 months (range, 64–128 months). The primary endpoint was the modified Harris hip score (HHS). The secondary endpoint was the major orthopaedic complication rate. Results The HHS showed significantly greater differences in the CTHA than UTHA group 12 months after conversion. From the 12th month after conversion to the final follow-up, CTHA yielded better functional outcomes than UTHA. There were significant differences between the UTHA and CTHA groups in the rates of re-revision (14.4% vs. 4.9%, respectively), aseptic loosening (17.3% vs. 6.8%, respectively), and periprosthetic fracture (11.5% vs. 3.9%, respectively). Conclusion CTHA has more advantages than UTHA in terms of improving functional outcomes and decreasing the major orthopaedic complication rate.

2020 ◽  
Author(s):  
Wenli Chen ◽  
Mao Shuai ◽  
Jinluan Lin ◽  
Baomin Chen ◽  
Mingdong Zhao ◽  
...  

Abstract Background A high rate of complications due to metal-on-metal (MoM) revisions has been relatively commonly documented. The purpose of this retrospective study was to compare the long-term outcomes of patients who had undergone uncemented or cemented total hip arthroplasty (THA) revision for prior primary MoM THA failure.Methods Data from 234 patients (234 hips) who underwent uncemented or cemented THA (UTHA or CTHA) for prior primary MoM THA failure during 2007 - 2018 were retrospectively analysed. Follow-up occurred 3 months, 6 months, 1 year, 2 years, and then every 1 year after conversion. The mean follow-up time was 84.15 months (range, 67 - 101 months). The primary endpoint was the modified Harris Hip Score (HHS). The secondary endpoint was the major orthopaedic complication rate.Results The HHS demonstrated statistically greater differences in the CTHA group than in the UTHA group 12 months after conversion. From the 12th month after conversion to the final follow-up, CTHA yielded better functional outcomes than UTHA. There were significant differences in the rates of re-revision, aseptic loosening, and periprosthetic fracture between the groups (10.3% for UTHA vs 2.5% for CTHA, p = 0.015; 16.3% for UTHA vs 5.9% for CTHA, p = 0.011; and 12.0% for UTHA vs 4.2% for CTHA, p = 0.045, respectively).Conclusion In the setting of revision for primary MoM THA failure, we found definite evidence of the superiority of CTHA over UTHA in terms of improving functional outcomes and decreasing the major orthopaedic complication rate.


2020 ◽  
Author(s):  
Wenli Chen ◽  
Mao Shuai ◽  
Jinluan Lin ◽  
Baomin Chen ◽  
Mingdong Zhao ◽  
...  

Abstract Background A high rate of metal-on-metal total hip arthroplasty (MoM-THA) has been well-known. The aim of this study was to compare the long-term outcomes of patients who had undergone uncemented or cemented THA(UTHA or CTHA) following initial MoM-THA failure. Methods Data from 234 patients (234 hips) who were treated with UTHA or CTHA following initial MoM-THA failure during 2007 - 2018 were retrospectively compared. Follow-up occurred 3 months, 6 months, 1 year, 2 years, and then every 1 year after conversion. The mean follow-up was 84.15 months (67 - 101 months). The primary endpoint was the Harris Hip Scores (HHS); secondary endpoint was the incidence of major orthopaedic complications. Results The HHS demonstrated statistically greater differences in Group CTHA than in Group UTHA 12 months after conversion. From the 12th month after conversion to the final follow-up, CTHA yielded superior functional outcomes than UTHA. Between-group noteworthy differences were observed regarding the rates of re-revision, aseptic loosening, and periprosthetic fracture (10.3% for UTHA vs 2.5% for CTHA, p = 0.015; 16.3% for UTHA vs 5.9% for CTHA, p = 0.011; and 12.0% for UTHA vs 4.2% for CTHA, p = 0.045, respectively). Conclusion In the setting of revision following initial MoM-THA failure, we found definite evidence of the superiority of CTHA over UTHA in regard to improving functional outcomes and decreasing the incidence of major orthopaedic complications.


2020 ◽  
Author(s):  
Wenli Chen ◽  
Mao Shuai ◽  
Jinluan Lin ◽  
Baomin Chen ◽  
Mingdong Zhao ◽  
...  

Abstract Background: A high rate of metal-on-metal total hip arthroplasty (MoM-THA) has been well-known. The aim of this study was to compare the long-term outcomes of patients who had undergone uncemented or cemented THA(UTHA or CTHA) following initial MoM-THA failure.Methods: Data from 234 patients (234 hips) who were treated with UTHA or CTHA following initial MoM-THA failure during 2007 - 2018 were retrospectively compared. Follow-up occurred 3 months, 6 months, 1 year, 2 years, and then every 1 year after conversion. The mean follow-up was 84.15 months (67 - 101 months). The primary endpoint was the Harris Hip Scores (HHS); secondary endpoint was the incidence of major orthopaedic complications.Results: The HHS demonstrated statistically greater differences in Group CTHA than in Group UTHA 12 months after conversion. From the 12th month after conversion to the final follow-up, CTHA yielded superior functional outcomes than UTHA. Between-group noteworthy differences were observed regarding the rates of re-revision, aseptic loosening, and periprosthetic fracture (10.3% for UTHA vs 2.5% for CTHA, p = 0.015; 16.3% for UTHA vs 5.9% for CTHA, p = 0.011; and 12.0% for UTHA vs 4.2% for CTHA, p = 0.045, respectively). Conclusion: In the setting of revision following initial MoM-THA failure, we found definite evidence of the superiority of CTHA over UTHA in regard to improving functional outcomes and decreasing the incidence of major orthopaedic complications.


2017 ◽  
Vol 2017 ◽  
pp. 1-7
Author(s):  
Shih-Jie Lin ◽  
Tsan-Wen Huang ◽  
Po-Chun Lin ◽  
Feng-Chih Kuo ◽  
Kuo-Ti Peng ◽  
...  

Long-term data and information indicating whether minimally invasive surgery (MIS) approaches are safe and effective with total hip arthroplasty (THA) are lacking. Between 2004 and 2006, 75 patients with alcohol-related osteonecrosis of the femoral head (ONFH) who underwent 75 THAs with the two-incision approach were studied. The medical records, radiographic parameters, and functional outcomes were collected prospectively. All data were compared with those for matched patients who underwent a modified Watson-Jones (WJ) approach. THA using the two-incision approach was associated with longer operation time, more blood loss, more lateral femoral cutaneous nerve injury, and more periprosthetic femoral fractures (p<0.05for all four) than the modified WJ approach. The Harris Hip Score (HHS) and Western Ontario and McMaster University Osteoarthritis Index (WOMAC) increased significantly from the period preoperatively to 6 weeks postoperatively and thereafter up to the last follow-up in both groups. However, there were no significant differences in terms of radiographic parameters and functional outcomes between the two groups throughout the study period. Both the two-incision and the modified WJ approach provided satisfactory results and survival rates at a mean follow-up of 10.8 years. A prospective, randomized, large-scale cohort study is still warranted for evidence-based recommendations.


Joints ◽  
2020 ◽  
Author(s):  
Christian Carulli ◽  
Giacomo Sani ◽  
Fabrizio Matassi ◽  
Roberto Civinini ◽  
Massimo Innocenti

Abstract Purrpose Metal-on-metal (MoM) total hip arthroplasty (THA) has been a subject of recent discussion and concern due to the early failures caused by local and systemic adverse reactions related to specific designs. The aim of this study is to analyze the outcomes and survival rates of a single brand of MoM implants implanted in a consecutive series of patients at a single institution. Methods Between 2007 and 2012, 116 (118 hips) patients were evaluated at a mean follow-up of 6.6 years after primary THA. The diagnosis leading to surgery was osteoarthritis (80 patients) and proximal femoral fracture (36 patients). A single design of THA was implanted. All patients were evaluated before surgery and postoperatively at 1, 3, 6, and 12 months by clinical scores and radiographic studies. The data analysis was made using Student's t-test. Results The minimum follow-up was of 4 years, with a mean follow-up of 6.6 years. Two aseptic loosenings of the acetabular component were recorded (one per group), which were not associated with local or systemic complications related to metal ion release. Both were revised by an isolated acetabular cup substitution with metal-on-polyethylene couplings. Nonprogressive radiolucency lines < 2 mm in zone 2 were observed in other six patients around the acetabular component without clinical manifestation (four in the arthritis group and two in the fracture group). Postoperative Harris Hip Score and SF-36 (36-Item Short Form Survey) score improved in both groups. Conclusion Despite several MoM implants showing early complications and failures, a specific MoM design may be associated with good clinical results at a mid- to long-term follow-up. Level of Evidence This is a therapeutic case series, Level 4 study.


2013 ◽  
Vol 5 (3) ◽  
pp. 20 ◽  
Author(s):  
Régis Pailhé ◽  
Nicolas Reina ◽  
Etienne Cavaignac ◽  
Akash Sharma ◽  
Valérie Lafontan ◽  
...  

There is a need of independent prospective studies about modern generation of hip resurfacing implants. The aim of this propective observational study was to compare the functional outcomes and revision rates with hip resurfacing arthroplasty and total hip arthroplasty and to present the preliminary results at 2 years. Patients included were recruited prospectively in the <em>Partial Pelvic Replacement Hip Project </em>by a single surgeon between January 2007 and January 2010. Patients were assessed with the Harris Hip Score (HHS) and Postel-Merle d’Aubigné (MDA) score and Devane Score. The end point of the study was reoperation for any cause related to the prosthesis. At a mean follow up of 38.6 months there were a total of 142 patients with hip resurfacing (group 1) [100 Durom® (Zimmer Inc., Warsaw, IN, USA) and 42 Birmingham Hip Resurfacing® (Smith &amp; Nephew, Memphis, TN, USA)] and 278 patients with total hip arthroplasty (group 2). The results showed significantly greater gain of HHS, MDA and Devane score with hip resurfacing procedures. However, considering all the complications, the rate was significantly higher in group 16.4% <em>vs</em> 1.79% in group 2 (P&lt;0.0001). In group 1 we observed 6 complications only concerned males with Durom® implants. The follow up of this cohort is still on going and may deliver more information on the evolution of these results in time.


2017 ◽  
Vol 2017 ◽  
pp. 1-7
Author(s):  
Chih-Chien Hu ◽  
Tsan-Wen Huang ◽  
Shih-Jie Lin ◽  
Po-Chun Lin ◽  
Feng-Chih Kuo ◽  
...  

Large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA) has lost popularity because of metal allergy or ALTRs (adverse local tissue reactions) in the past decade. Whether the surgical approach may influence the survival of LDH-MoM-THA has not been reported. From 2006 to 2009, we performed 96 LDH-MoM-THAs on 80 patients using an in situ head-neck assembly technique through a modified Watson-Jones approach. With a mean follow-up of 8.4 years (range, 6.3–10.1 years), the implant survival rate was 100%. All patients were satisfied with the results and the Harris Hip Score improved from 52 points to 98 points. No ALTRs were found, but 17.7% of the 96 hips (17 adverse events) experienced adverse events related to the cup, including 5 cases of outlier cup malposition, 11 cases of inadequate cup seating, and 1 acetabular fracture. The tissue tension that was improved by a muscle-sparing approach might lessen the chance of microseparation or edge-loading that is taken as the major risk for early implant failure. Further investigation of whether these LDH-MoM-THAs would fail or not would require a longer follow-up or even retrieval analysis in the future.


2020 ◽  
Vol 9 (3) ◽  
pp. 146-151 ◽  
Author(s):  
Wenzel Waldstein ◽  
Ulrich Koller ◽  
Bernhard Springer ◽  
Paul Kolbitsch ◽  
Wolfram Brodner ◽  
...  

Aims Second-generation metal-on-metal (MoM) articulations in total hip arthroplasty (THA) were introduced in order to reduce wear-related complications. The current study reports on the serum cobalt levels and the clinical outcome at a minimum of 20 years following THA with a MoM (Metasul) or a ceramic-on-polyethylene (CoP) bearing. Methods The present study provides an update of a previously published prospective randomized controlled study, evaluating the serum cobalt levels of a consecutive cohort of 100 patients following THA with a MoM or a CoP articulation. A total of 31 patients were available for clinical and radiological follow-up examination. After exclusion of 11 patients because of other cobalt-containing implants, 20 patients (MoM (n = 11); CoP (n = 9)) with a mean age of 69 years (42 to 97) were analyzed. Serum cobalt levels were compared to serum cobalt levels five years out of surgery. Results The median cobalt concentration in the MoM group was 1.04 μg/l (interquartile range (IQR) 0.64 to 1.70) at a mean of 21 years (20 to 24) postoperatively and these values were similar (p = 0.799) to cobalt levels at five years. In the CoP control group, the median cobalt levels were below the detection limit (< 0.3 μg/l; median 0.15 μg/l, IQR 0.15 to 0.75) at 20 years. The mean Harris Hip Score was 91.4 points (61 to 100) in the MoM group and 92.8 points (63 to 100) in the CoP group. Conclusion This study represents the longest follow-up series evaluating the serum cobalt levels after 28 mm head MoM bearing THA and shows that serum cobalt concentrations remain at low levels at a mean of 21 years (20 to 24) after implantation. Cite this article: Bone Joint Res. 2020;9(3):145–150.


2021 ◽  
Vol 12 ◽  
pp. 215145932110132
Author(s):  
Zhenfa Zhang ◽  
Guixing Xu ◽  
Lei Cao ◽  
Wei Sun ◽  
Xianshang Zeng ◽  
...  

Introduction: Patient outcomes following modern dual-mobility cup total hip arthroplasty (DM-THA) remains a concern. Few reports have focused on the use of modern DM-THA in the setting of Asian populations for displaced osteoporotic femoral neck fractures (FNFs). This study aimed to investigate the outcomes of Chinese population with displaced osteoporotic FNFs initially treated with modern DM-THA. Materials and Methods: Data from 112 consecutive patients (112 hips) with displaced osteoporotic FNFs initially treated with modern DM-THA during 2011-2018 were retrospectively analyzed. Follow-ups were performed at 3 months, 6 months, 12 months, and then every 1 year after surgery. The primary endpoint was the Harris Hip Score (HHS); the secondary endpoint was the main orthopedic complication rate. Results: The mean HHS improved from 58.62 (±15.79) prior to surgery to 86.13 (±9.92) at the final follow-up. The main complication rate was 14.2% (16/112). Sixteen complications in 10 patients were recorded. Of the 16 complications, there were 2 (1.7%) cases requiring revision DM-THA, 3 (2.6%) cases of loosening, 2 (1.7%) cases of migration, 3 (2.6%) intra-prosthetic dislocation (IPD), 4 (3.5%) cases of tilting, and 2 (1.7%) cases of severe wear. The need for revision was attributed to prosthesis loosening associated with poor bony quality. Conclusion: In patients with displaced osteoporotic FNFs, DM-THA may yield favorable functional outcomes and a low rate of main orthopedic complications, in particular, a low dislocation rate.


2019 ◽  
Vol 101-B (3) ◽  
pp. 317-324 ◽  
Author(s):  
J-K. Moon ◽  
Y. Kim ◽  
K-T. Hwang ◽  
J-H. Yang ◽  
J-A. Ryu ◽  
...  

Aims The present study investigated the five-year interval changes in pseudotumours and measured serum metal ions at long-term follow-up of a previous report of 28 mm diameter metal-on-metal (MoM) total hip arthroplasty (THA). Patients and Methods A total of 72 patients (mean age 46.6 years (37 to 55); 43 men, 29 women; 91 hips) who underwent cementless primary MoM THA with a 28 mm modular head were included. The mean follow-up duration was 20.3 years (18 to 24). All patients had CT scans at a mean 15.1 years (13 to 19) after the index operation and subsequent follow-up at a mean of 20.2 years (18 to 24). Pseudotumour volume, type of mass, and new-onset pseudotumours were evaluated using CT scanning. Clinical outcomes were assessed by Harris Hip Score (HHS) and the presence of groin pain. Serum metal ion (cobalt (Co) and chromium (Cr)) levels were measured at the latest follow-up. Results At final follow-up, pseudotumours were observed in 26/91 hips (28.6%). There was an increase in volume of the pseudotumour in four hips (15.4%), no change in volume in 21 hips (80.8%), and a decrease in volume in one hip (3.8%). There were no new-onset pseudotumours. There was no significant difference in HHS between patients with and without pseudotumours. At final follow-up, mean serum Co ion levels and median Co:Cr ratios were significantly greater in patients with pseudotumours, but the serum Cr ion levels were not significantly different. Conclusion At a mean 20 years of follow-up, pseudotumours were observed in 26/91 hips (28.6%) with no new-onset pseudotumours during subsequent follow-up. Most pseudotumours in small-head MoM THA were static in volume and asymptomatic with normal serum metal ion levels. Cite this article: Bone Joint J 2019;101-B:317–324.