Management of feline tibial diaphyseal fractures using orthogonal plates performed via minimally invasive plate osteosynthesis

2017 ◽  
Vol 20 (1) ◽  
pp. 6-14 ◽  
Author(s):  
Andrew Craig ◽  
Philip G Witte ◽  
Tristram Moody ◽  
Karen Harris ◽  
Harry W Scott

Objectives The objective was to assess the medium- and long-term outcomes (radiographic and owner questionnaire) of feline tibial diaphyseal fractures with orthogonal plate fixation via a minimally invasive plate osteosynthesis (MIPO) approach. Methods Medical records and radiographs of cats that had tibial diaphyseal fractures stabilised with orthogonal plates were obtained (2012–2016). Immediate postoperative radiographs were reviewed to assess the construct configuration and follow-up radiographs (where available) were used to assess bone healing and implant-related complications. An owner-completed questionnaire (feline musculoskeletal pain index [FMPI]) was used at a minimum of 6 months following surgery to assess the cats’ ability to perform normal activities. Results Eight feline tibial diaphyseal fractures met the inclusion criteria. One major complication was observed, most likely due to an operative technical error. There were no further complications following revision surgery. Six of the eight cases that had radiographic follow-up either had clinical bone union or showed evidence of bone healing. All cases were classified as successful according to FMPI. Conclusions and relevance Orthogonal plating of feline tibial diaphyseal fractures via an MIPO approach resulted in successful outcomes and a lower complication rate compared with previously reported techniques.

Author(s):  
Apipop Kritsaneephaiboon ◽  
Watit Wuttimanop ◽  
Surasak Jitprapaikulsarn ◽  
Pornpanit Dissaneewate ◽  
Chulin Chewakidakarn ◽  
...  

2012 ◽  
Vol 25 (05) ◽  
pp. 410-417 ◽  
Author(s):  
A. Boero Baroncelli ◽  
B. Peirone ◽  
M. D. Winter ◽  
D. J. Reese ◽  
A. Pozzi

SummaryObjectives: To compare fracture healing in diaphyseal tibial fractures stabilized using either minimally invasive plate osteosynthesis (MIPO) or open reduction and internal fixation (ORIF).Methods: Dogs in each group were matched for type of fracture, age and body weight. Stage of healing was measured blindly every four weeks postoperatively until complete healing. Outcome variables including fracture length, plate length, plate bridging ratio, plate working length, healing grading, and fracture reduction were compared between groups using the Mann-Whitney test. Significant difference was set at p <0.05.Results: Based on the definition of clinical union, at 30 days five out of eight dogs managed with MIPO had healed, while two of the eight of dogs managed with ORIF had healed. We did not find any significant differences in the other outcome measures. No complications were reported in the MIPO group whereas one major complication was reported in the ORIF group.Clinical significance: All dogs treated by MIPO healed rapidly without any complications, nevertheless the difference in radiographic healing between the two groups was not significant.


2021 ◽  
Vol 51 (9) ◽  
Author(s):  
Jose Sergio Costa Junior ◽  
Rafael Manzini Dreibi ◽  
Guilherme Galhardo Franco ◽  
Luis Gustavo Gosuen Gonçalves Dias ◽  
Rogerio Giuffrida ◽  
...  

ABSTRACT: This study assessed radiographically changes in tibial alignment in the frontal and sagittal planes in dogs that underwent minimally invasive plate osteosynthesis (MIPO) without the aid of image intensifiers. Radiographs of dogs with complete non-articular tibial fractures submitted to MIPO were included and evaluated, without the aid of a transoperative image intensifier and / or an association of implants. The tibial mechanical angles (mMPTA, mMDTA, mCaPTA and mCrDTA) were measured by three evaluators. The data obtained were compared with results from previously published studies. Twenty-seven animals were included in the study. The mean and standard deviation of the angular changes were as follows: mMPTA, 2.54° ± 3.10 (-1.1º to 8.7º); mMDTA, 0.03º ± 0.16 (-3.44º to 0.79º); mCaPTA, 37º ± 4.29 (-6.23º to 14.87º); and mCrDTA, 8.25° ± 5.53 (-0.2º to 17.28º). There was a negative correlation between “mCaPTA” and “mCrDTA”. MIPO of the tibia without using image intensifiers and implant association can potentially cause angular changes, which can lead to clinically relevant deformities after bone healing.


Author(s):  
Abhishek Kumar ◽  
Rahul Bade

<p class="abstract"><strong>Background:</strong> Shaft of humerus (SOH) fracture has been conventionally treated with either open reduction internal fixation with plate osteosynthesis or immobilization as conservative treatment. Intramedullary interlocking nailing (IMIL) and anterior bridge plating (ABP) are both newer modalities of internal fixation for SOH fracture. Rotator cuff irritation is a known complication of IMIL nailing of the humerus. Here, we present clinical, radiological, and functional outcome of SOH fracture fixation by ABP using a minimally invasive method.</p><p class="abstract"><strong>Methods:</strong> Thirty patients with SOH fracture were treated surgically via an anterior minimally invasive plate osteosynthesis (MIPO) approach with ABP. There were 21 male and 9 female patients, and the average age was 38.6±10.45 years. The mechanism of injury was road traffic accidents (60%) and ground level fall (40%). Functional assessments were obtained with University of California at Los Angeles (UCLA) score and mayo elbow performance index (MEPI) during the follow-up period.<strong></strong></p><p class="abstract"><strong>Results:</strong> At the end of 6 months follow-up, 29 (96.7%) patients had excellent to good UCLA and MEPI scores. Varus/valgus angulation was reported in 4 (13.3%) patients. Two patients (6.7%) had radial nerve neuropraxia and delayed union, while 1 (3.3%) patient had screw back-out or loosening. The mean duration of radiation exposure was 178±41.2 seconds. ABP for SOH fractures is a safe and effective treatment modality.</p><p class="abstract"><strong>Conclusions:</strong> This treatment protocol produces high rates of union, excellent functional recovery, and minimal biological disruption.</p>


Sign in / Sign up

Export Citation Format

Share Document