Comparison between different tonometers following intrastromal corneal ring segments implantation

2021 ◽  
pp. 112067212110425
Author(s):  
Mennatullah M Elfwwal ◽  
Mohamed K Elbasty ◽  
Mohamed F Khattab ◽  
Malak I ElShazly

Purpose: To compare different intraocular pressure (IOP) readings in corneas with intrastromal corneal ring segments (ICRS) taken by three different tonometers; Goldmann applanation tonometry (GAT), air puff tonometer, and ocular response analyzer (ORA) corneal-compensated IOP (ORA-IOPcc) and determine the relation of these measurements to different corneal parameters taken by Pentacam. Methods: An observational cross-sectional analytic study included patients who underwent ICRS keraring implantation at 3 months. In each eye, the two rings were placed using the femtosecond laser assisted technique 5.5 or 6 mm from the center. IOP was measured using three different tonometers; GAT, air puff tonometer, and ocular response analyzer (ORA) corneal-compensated IOP (ORA-IOPcc). Results: Fifty eyes of 30 patients (20 males and 10 females) aged 27.56 ± 6.38 years were included. IOP measurements by GAT, air puff tonometer, and ORA-IOPcc were 13.28 ± 2.13 mmHg, 10.47 ± 2.55 mmHg, and 13.19 ± 2.78 mmHg, respectively. Comparisons between air puff and each of GAT and ORA-IOPcc were statistically highly significant ( p-value <0.001). Conclusion: IOP measurements taken by air puff tonometer were significantly lower than those taken by GAT and ORA-IOPcc. These differences were not constant across the pressure range but increased as the pressure values determined using GAT and ORA increased. ORA-IOPcc and GAT showed similar readings. No correlation was found between any of the IOP readings taken by the three tonometers and the central corneal thickness.

2021 ◽  
Vol 9 (2) ◽  
pp. 127-133
Author(s):  
Annamary Stanislaus ◽  
Ntsilane Susan Mosenene ◽  
Celina Mhina ◽  
John Stanslaus Kisimbi ◽  
Frederick Robert Burgess ◽  
...  

Background: Central Corneal Thickness (CCT) is an indicator of corneal health status as well as being an essential tool in assessment and management of corneal diseases. It is an important factor in the diagnosis and management of glaucoma as it affects the measurement of intraocular pressure. However, the pattern of central corneal thickness in our population is not known. Our study aimed to describe the CCT measurements and their variation with age and sex among patients attending the eye clinic at Muhimbili National Hospital (MNH), in Dar es Salaam, Tanzania. Methodology: A hospital-based descriptive, cross-sectional study used convenient sampling to recruit adult patients aged 18 years and above, presenting to the MNH between August 2016 and January 2017.Visual acuity assessment, Goldman applanation tonometry and CCT assessment using an ultrasound pachymeter were performed. Patients with previous intraocular surgery were excluded. Results: A total of 398 patients (208 males and 190 females) were recruited. The mean CCT was 526.64±38.30 µm; being 523.99±38.20 µm for males and 529.7±38.3 µm for females. 226 (56.85%) had CCT of less than 520 µm.There was no statistically significant difference in CCT between gender. The proportion of patients with thinner CCT increased with increasing age from 25.8% in those < 30 years to 75% in those aged 71years and above. The mean CCT decreased with increasing age with P-value<0.001. Conclusion: The average CCT in patients attending Muhimbili National Hospital is 526.64 µm (SD 38.30) which is generally thin, inversely proportion to age and similar that of other Africans and African-Americans. This finding has implications for the management of glaucoma in this population.


2019 ◽  
Vol 30 (6) ◽  
pp. 1432-1439 ◽  
Author(s):  
Lisa Ramm ◽  
Robert Herber ◽  
Eberhard Spoerl ◽  
Lutz E Pillunat ◽  
Naim Terai

Purpose: To investigate the impact of diabetes mellitus–induced changes on intraocular pressure measurements using Goldmann applanation tonometry, Ocular Response Analyzer, and Corvis ST. Methods: Measurements were done using Goldmann applanation tonometry, Ocular Response Analyzer, and Corvis ST in 69 diabetic patients. Biomechanical-corrected intraocular pressure values by Ocular Response Analyzer (IOPcc) and Corvis ST (bIOP) were used. In addition, biometry and tomography were performed and information on diabetes mellitus specific factors was collected. Results were compared to an age-matched group of 68 healthy subjects. Results: In diabetes mellitus, Goldmann applanation tonometry intraocular pressure (P = 0.193) and central corneal thickness (P = 0.184) were slightly increased. Also, IOPcc (P = 0.075) and bIOP (P = 0.542) showed no significant group difference. In both groups, IOPcc was higher than Goldmann applanation tonometry intraocular pressure (P = 0.002, P < 0.001), while bIOP was nearly equal to Goldmann applanation tonometry intraocular pressure (P = 0.795, P = 0.323). Central corneal thickness showed a tendency to higher values in poorly controlled than in controlled diabetes mellitus (P = 0.059). Goldmann applanation tonometry intraocular pressure correlated to central corneal thickness, while IOPcc and bIOP were independent from central corneal thickness in both groups. All intraocular pressure values showed significant associations to corneal biomechanical parameters. Only in diabetes mellitus, bIOP was correlated to Pachy slope (P = 0.023). Conclusion: In diabetes mellitus, Goldmann applanation tonometry intraocular pressure was slightly, but not significantly, increased, which might be caused by a higher central corneal thickness and changes in corneal biomechanical properties. However, intraocular pressure values measured by Ocular Response Analyzer and Corvis ST were not significantly different between diabetes mellitus patients and healthy subjects. The bIOP showed a higher agreement with Goldmann applanation tonometry than IOPcc and was independent from central corneal thickness.


1970 ◽  
Vol 12 (3) ◽  
pp. 156-158
Author(s):  
Ozlem Gurses Sahin

Aim: To evaluate whether a significant difference exists between the initial and final mean central corneal thickness that might affect Goldmann applanation tonometer recordings of patients with allergic conjunctivitis treated with desonide 0.25% ophthalmic solution, and to determine the effect of desonide on intraocular pressure by using adjusted intraocular pressure values.Methods: This double-blind randomised placebo-controlled trial enrolled 30 patients (60 eyes) with allergic conjunctivitis. Patients were randomly assigned to receive desonide to 1 eye (study eye) and preservative-free tear supplement (Tears Naturale Free®) to the other eye (control eye) 3 times daily for 3 weeks. Goldmann applanation tonometry and central corneal thickness of both eyes were recorded on the day of presentation and 3 weeks later.Results: Regression of itching, tearing, conjunctival hyperaemia, and tarsal conjunctival papillary reaction were noted in the study eyes after 3 weeks of treatment. The control eyes showed mild regression of pruritis, tearing, conjunctival hyperaemia, and tarsal conjunctival papillary reaction after 3 weeks. There was a significant difference between the initial and final mean central corneal thickness values for the study eyes (p = 0.003). There were no statistically significant differences between the initial and final mean values of Goldmann applanation tonometry and adjusted intraocular pressure for the study eyes. No statistically significant differences were found between the initial and final mean values of any of the parameters for the control eyes.Conclusion: Inflammation-induced increase in central corneal thickness of patients with allergic conjunctivitis treated with desonide showed statistically significant regression. However, this regression did not significantly affect Goldmann applanation tonometry and adjusted intraocular pressure values of the treated eyes.


2016 ◽  
Vol 15 (2) ◽  
Author(s):  
Satheesh Solomon T Selvin ◽  
Chris Elsa Samson Jacob ◽  
Thomas Kuriakose

Purpose: Goldmann applanation tonometry (GAT) is considered the gold standard for Intraocular Pressure (IOP) measurement. It has the disadvantages of being a contact device, need for a slit-lamp, non-portability and need of a skilled examiner. Many hospitals are using a Non Contact Tonometry (NCT) as a screening device to save clinician time, however the usefulness is not proved in terms of reliability. This study was aimed to determine the usefulness of the Air-puff tonometer (TONOREF NIDEK II, NIDEK CO., LTD., JAPAN) over a GAT in a tertiary care center. Design: Cross-sectional Study Methods: This was a cross-sectional, non interventional observational study conducted on 224 eyes (right eye) from 224 patients. All patients underwent the IOP measurement with both methods and a central corneal thickness (CCT) measured. The data was analyzed using SPSS 20.0 software. Results: The mean age of the patients was 40.3±11.29 years. There was a statistically significant difference (p<0.001) between the mean NCT and GAT readings which persisted even after correction for central corneal thickness. The correlation between NCT and GAT using Pearson’s correlation coefficient was strong irrespective of the corrections for their corneal thickness (r = 0.751 and 0.718 for uncorrected and corrected values respectively). The correlation of the individual clinicians for the readings varied from moderate to strong. The ROC curve showed the best sensitivity and specificity to occur at around 13 to 14 mmHg. Conclusion: NCT seems to overestimate the IOP at low ranges as compared to the GAT and underestimate at higher ranges. The crossover of the values is seen between 12 to 13 mmHg.  The clinician should do an individualized analysis of his/her GAT measurements to the readings of the NCT machine at the clinic to obtain clinician specific nomogram. 


Author(s):  
Neethu K. V. ◽  
Latha N. V. ◽  
Praveena K. K.

Background: Brimonidine is a potent ocular hypotensive agent widely used in glaucoma treatment. A reduction in central corneal thickness can lead to an underestimation of intraocular pressure by Goldmann applanation tonometry and vice versa. The aim of this study is to determine whether brimonidine has an effect on central corneal thickness.Methods: 30 eyes of patients who attended the Ophthalmology OPD between the time period October 2017 and June 2018 who were newly diagnosed with normal tension glaucoma with no history of any systemic illness or not on any medication were included. Each patient underwent a complete ophthalmic evaluation including fundus examination, visual field assessment, intraocular pressure, central corneal thickness measurement by pachymetry before as well as 1 month and 6 months after starting treatment with 0.2% topical brimonidine twice daily.Results: Administration of brimonidine 0.2% resulted in an increase in central corneal thickness from 525±21 µm before starting brimonidine to 528±21 µm (p<0.05) after 1 month and 535±20 µm (p<0.001) after 6 months. It also resulted in a reduction in intraocular pressure from an initial value of 16±2 mmHg before starting brimonidine to 14±2 mmHg (p<0.05) and 13±2 mmHg (p<0.05), 1month and 6 months after starting treatment, respectively.Conclusions: The data presented in this study show that topical administration of 0.2% brimonidine twice daily results in a significant increase in central corneal thickness in patients with normal tension glaucoma.


2019 ◽  
Vol 104 (4) ◽  
pp. 563-568 ◽  
Author(s):  
Masato Matsuura ◽  
Hiroshi Murata ◽  
Yuri Fujino ◽  
Mieko Yanagisawa ◽  
Yoshitaka Nakao ◽  
...  

AimsCorvis ST (CST) yields biomechanical corrected IOP (bIOP) which is purported to be less dependent on biomechanical properties. In our accompanied paper, it was suggested that the repeatability of bIOP is high. The purpose of the current study was to assess the relationship between intraocular pressure (IOP) measured with CST and central corneal thickness (CCT) and corneal hysteresis (CH), in comparison with IOP measured with Goldmann applanation tonometry (GAT) and the ocular response analyzer (ORA).MethodsA total of 141 eyes from 141 subjects (35 healthy eyes and 106 glaucomatous eyes) underwent IOP measurements with GAT, CST and ORA. The relationships between IOP measurements (ORA-IOPg, ORA-IOPcc, CST-bIOP and GAT IOP) and biomechanical properties (CCT, CH and corneal resistance factor (CRF)) were analysed using the linear regression analysis.ResultsIOPg, IOPcc and GAT IOP were significantly associated with CCT (p<0.001), whereas bIOP was not significantly associated with CCT (p=0.19). IOPg, bIOP and GAT IOP were significantly associated with CH (IOPg: p<0.001; bIOP: p<0.001; GAT IOP: p=0.0054), whereas IOPcc was not significantly associated with CH (p=0.18). All of IOP records were associated with CRF (p<0.001).ConclusionThe bIOP measurement from CST is independent from CCT, but dependent on CH and CRF.


2019 ◽  
Vol 2019 ◽  
pp. 1-9
Author(s):  
Lisa Ramm ◽  
Robert Herber ◽  
Eberhard Spoerl ◽  
Frederik Raiskup ◽  
Lutz E. Pillunat ◽  
...  

Purpose. To compare intraocular pressure (IOP) measurements with Goldmann applanation tonometry (GAT), ocular response analyzer (ORA), dynamic contour tonometer (DCT), and Corvis ST (CST) in healthy subjects. Methods. In a prospective, observational study, IOP measurements with GAT (GAT-IOPc), ORA (IOPcc), DCT (DCT-IOP), and CST (bIOP) were performed and analyzed in 94 healthy subjects. Results. Mean age of the participants was 45.6 ± 17.2 years (range 18 to 81 years). Mean GAT-IOPc was 12.9 ± 2.4 mmHg, mean DCT-IOP was 16.1 ± 2.6 mmHg, and mean IOPcc was 15.6 ± 3.3 mmHg. DCT-IOP and IOPcc were significantly higher than GAT-IOPc (P<0.001). Mean bIOP was 13.5 ± 2.4 mmHg that was slightly higher but not significantly different from GAT-IOPc (P=0.146). Correlation analysis of IOP values and central corneal thickness (CCT) revealed a negative correlation between GAT-IOPc and CCT (r = −0.347; P=0.001). However, IOPcc, DCT-IOP, and bIOP showed no significant correlation to CCT. Only bIOP revealed a weak but significant age dependency (r = 0.321, P=0.002). Conclusion. All tonometry devices showed a good agreement of biomechanical corrected IOP values with GAT-IOPc. As no influence of CCT on IOPcc, DCT-IOP, and bIOP was detectable, the used correction algorithms appear to be appropriate in these tonometers in the clinical setting. The highest agreement was found between GAT-IOPc and bIOP. However, bIOP weakly correlated with participants’ age. Further studies are needed to elucidate the role of bIOP for IOP measurement.


Vision ◽  
2020 ◽  
Vol 4 (4) ◽  
pp. 45
Author(s):  
Marco Antonio de Castro Olyntho Junior ◽  
Lucas Bertazzi Augusto ◽  
Carolina P. B. Gracitelli ◽  
Andrew J. Tatham

Evaluate the effect of corneal thickness, densitometry and curvature on intraocular pressure (IOP) measurements obtained by Goldmann applanation tonometry (GAT), non-contact tonometry (NCT), rebound tonometry (RT), and dynamic contour tonometry (DCT). A cross-sectional prospective study involving 40 participants was performed. Corneal measurements were obtained using Pentacam (Oculus GMbH, Wetzlar, Germany), densitometry was measured at annuli of 0–2, 2–6, 6–10 and 10–12 mm. The relationship between corneal thickness (central, 4 and 6 mm), corneal astigmatism and corneal densitometry and IOP was examined. There was a significant relationship between corneal thickness (central, 4 and 6 mm) and GAT180, GAT90, RT, and NCT (P < 0.001 for all comparisons) but not for DCT. Higher corneal densitometry (6–10 mm and 10–12 mm zones) was associated with higher IOP from GAT180 and GAT90, and higher densitometry in the 6–10 mm zone correlated with higher IOP from NCT, however corneal densitometry increased with age. Accounting for age, the relationship between corneal densitometry and IOP measurements was not significant. In eyes with greater corneal astigmatism there was a greater difference between GAT90 and GAT180 measurements. IOP measurements may be affected by corneal thickness, densitometry and curvature. DCT was less affected by properties of the cornea compared to other devices.